Schneider Electric C10F2TM063 ComPacT NSX100F 2P 63 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F2TM050 ComPacT NSX100F 2P 50 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F2TM040 ComPacT NSX100F 2P 40 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F2TM030 ComPacT NSX100F 2P 30 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F2TM025 ComPacT NSX100F 2P 25 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F2TM016 ComPacT NSX100F 2P 16 A 18 kA at 415 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F1TM100 ComPacT NSX100F 1P 100 A 18 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F1TM020 ComPacT NSX100F 1P 20 A 18 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F1TM016 ComPacT NSX100F 1P 16 A 18 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker
Schneider Electric C10F4TM080D1 ComPacT NSX80 DC PV 4P 80 A 10 kA DC TM-DC Fixed Moulded Case Circuit Breaker
Schneider Electric ComPacT NSX MCCBs are molded case circuit breakers for 12.5 A to 630 A distribution and motor circuits. The range covers 1 to 4 poles across NSX100, NSX250, NSX400 and NSX630 frames, with more than 350 products. Stoklink ships worldwide from Turkey and quotes volumes on request.
What's in this range
- NSX100 and NSX250 frames with TM-D thermal-magnetic trip units.
- NSX400 and NSX630 frames with MicroLogic electronic trip units.
- Breaking capacity classes from F up to R, with up to 200 kA on NSX630R.
- Spare parts: MCCB Accessories, Releases & Trip Units.
How to choose
- Frame size sets the current range. Pick the smallest frame that carries the load.
- Breaking capacity class (F, N, H, S, L, R) must exceed the fault level.
- Pick TM-D for simple feeders and MicroLogic for adjustable protection and measurement.
FAQ
What does the letter in NSX250H mean?
It is the breaking capacity class. Letters rise in breaking capacity, and the title lists the kA figure for the exact part.
What is the difference between TM-D and MicroLogic?
TM-D is a thermal-magnetic trip unit. MicroLogic is an electronic trip unit with adjustable protection settings.
Can you export ComPacT NSX breakers?