Filter

Motor Control & Protection Categories

Motor Control & Protection

Filter
Showing 1 - 2100 of 3212 items

Schneider Electric LE1M35M712 TeSys LE DOL Starter 3P 3.7-5.5 A 2.2 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1M35M712
Rated Current (A): 5.5
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$65.60

Schneider Electric LE1M35M710 TeSys LE 1.5kW 2.6-3.7A 380/400V AC Enclosed DOL Starter

Reference No: LE1M35M710
Rated Current (A): 3.7
20 pcs in stock
$82.34

Schneider Electric LE1M35M708 TeSys LE DOL Starter 3P 1.8-2.6 A 1.1 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1M35M708
Rated Current (A): 2.6
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$65.60

Schneider Electric LE1M35M707 TeSys LE DOL Starter 3P 1.2-1.8 A 0.55 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1M35M707
Rated Current (A): 1.8
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$65.60

Schneider Electric LE1M35M706 TeSys LE DOL Starter 3P 0.8-1.2 A 0.37 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1M35M706
Rated Current (A): 1.2
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$65.60

Schneider Electric LE1M35M705 TeSys LE DOL Starter 3P 0.54-0.8 A 0.25 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1M35M705
Rated Current (A): 0.8
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$65.60

Schneider Electric LE1D18M7 TeSys Deca Enclosed DOL Starter 3P 17 A 7.5 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1D18M7
Rated Current (A): 17
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$104.27

Schneider Electric LE1D12M7 TeSys Deca Enclosed DOL Starter 3P 12 A 5.5 kW 220 V AC Coil IP65 Motor Starter

Reference No: LE1D12M7
Rated Current (A): 12
Rated Voltage (VAC): 220 V AC
0 pcs in stock
$101.61

Schneider Electric LE1D09M7 TeSys LE 9A Enclosed DOL Starter

Reference No: LE1D09M7
Rated Current (A): 9
1 pcs in stock
$111.17

Schneider Electric LT6CT4001 TeSys T Current Transformer 400/1 Class 5P Automation Component

Reference No: LT6CT4001
0 pcs in stock
$130.84

Schneider Electric LT6CT2001 TeSys T Current Transformer 200/1 Class 5P Automation Component

Reference No: LT6CT2001
0 pcs in stock
$118.88

Schneider Electric LT6CT1001 TeSys T Current Transformer 100/1 Class 5P Automation Component

Reference No: LT6CT1001
0 pcs in stock
$118.88

Schneider Electric LRD4369 GV2DM TeSys Deca 3P 110-140A Thermal Overload Relay

Reference No: LRD4369
Rated Current (A): 140
Number of Poles: 3P
5 pcs in stock
$253.13

Schneider Electric LRD4367 GV2DM TeSys Deca 3P 95-120A Thermal Overload Relay

Reference No: LRD4367
Rated Current (A): 120
Number of Poles: 3P
7 pcs in stock
$207.72

Schneider Electric LRD4365 LT6CT TeSys Deca 80-104A Thermal Overload Relay

Reference No: LRD4365
Rated Current (A): 104
2 pcs in stock
$198.96

Schneider Electric LRD365 TeSys Deca 48-65A Thermal Overload Relay

Reference No: LRD365
Rated Current (A): 65
45 pcs in stock
$91.40

Schneider Electric LRD350 TeSys Deca 37-50A Thermal Overload Relay

Reference No: LRD350
Rated Current (A): 50
72 pcs in stock
$88.90

Schneider Electric LRD35 TeSys Deca 30-38A Thermal Overload Relay

Reference No: LRD35
Rated Current (A): 38
27 pcs in stock
$57.07

Schneider Electric LRD340 TeSys Deca 30-40A Thermal Overload Relay

Reference No: LRD340
Rated Current (A): 40
100 pcs in stock
$86.57

Schneider Electric LRD33696 TeSys Deca 110-140A Thermal Overload Relay

Reference No: LRD33696
Rated Current (A): 140
8 pcs in stock
$249.18

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.