- Home
- Circuit Breakers & Protection
- ABB 1SDA067428R1 XT1N 160 TMD 160-1600 4p F F InN=100% 4-Pole 160A Fixed Moulded Case Circuit Breaker ABB 1SDA067428R1 XT1N 160 TMD 160-1600 4p F F InN=100% 4-Pole 160A Fixed Moulded Case Circuit Breaker
ABB 1SDA067428R1 XT1N 160 TMD 160-1600 4p F F InN=100% 4-Pole 160A Fixed Moulded Case Circuit Breaker
ABB 1SDA067428R1 XT1N 160 TMD 160-1600 4p F F InN=100% 4-Pole 160A Fixed Moulded Case Circuit Breaker
Get Quote
- Description
The ABB 1SDA067428R1 XT1N 160 TMD 160-1600 4p F F InN=100% is a 4-pole, 160 A fixed-mount moulded case circuit-breaker from the Tmax XT1 series, engineered for transformer, generator, and installation protection in industrial distribution systems. Featuring a thermal-magnetic TMD trip unit with full 100% neutral pole protection (InN=100%), this breaker delivers dependable overload and short-circuit interruption in a compact 101.6 × 130 × 70 mm footprint. Certified to IEC 60947-2, CE, ATEX, and multiple additional standards, the XT1N 160 TMD 160-1600 4p F F InN=100% is the specification-ready choice for panel builders and procurement engineers worldwide.
Technical Specifications
| Catalog Number | XT1N 160 TMD 160-1600 4p F F InN=100% |
| SKU | 1SDA067428R1 |
| Brand | ABB |
| Series | Tmax XT1 |
| Model | XT1N |
| EAN / Barcode | 8015644013226 |
| Rated Current | 160 A |
| Number of Poles | 4P |
| Trip Unit | TMD (Thermal-Magnetic) |
| Current Setting Range | 160–1600 A |
| Neutral Protection | InN = 100% |
| Mounting Type | Fixed (F F) |
| Breaking Capacity (Icu @ 400 V AC) | 36 kA |
| Dimensions (W × H × D) | 101.6 mm × 130 mm × 70 mm |
| Weight | 1.4 kg |
Certifications & Standards
- IEC 60947-2: International standard for low-voltage switchgear — circuit-breakers
- CE: Conformité Européenne — meets EU safety, health, and environmental requirements
- VDE: German Association for Electrical, Electronic & Information Technologies certification
- ATEX: Certified for use in potentially explosive atmospheres (EU Directive 2014/34/EU)
- RoHS: Restriction of Hazardous Substances — compliant with EU Directive 2011/65/EU
- REACH: Registration, Evaluation, Authorisation and Restriction of Chemicals compliance
- EU Directive 2011/65/EU: RoHS recast directive compliance
- Amendment 2015/863: RoHS Annex II amendment — restricted substances compliance
- EN 45555: General methods for assessing the energy efficiency of networked standby products
- UL 2799: Standard for Electrical Systems for Stationary Fuel Cell Power Systems
- WEEE: Waste Electrical and Electronic Equipment Directive — responsible end-of-life disposal
Applications & Use Cases
- Transformer secondary-side protection in industrial and commercial power distribution panels
- Generator output protection for standby and prime-power applications
- Feeder and installation protection in LV switchboards up to 160 A
- 4-wire systems requiring full 100% neutral pole protection (InN=100%)
- Control panels in manufacturing, utilities, oil & gas, and building services
- ATEX-rated installations in hazardous area electrical systems