Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- ABB Basic M MCBs
Filter
ABB Basic M MCBs
ABB 2CDS653061R0165 BMS613B16 3P 16A 6kA 400V DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0205 BMS613B20 3P 20A 6kA 400V DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0255 BMS613B25 3P 25A 6kA 400V AC Miniature Circuit Breaker
ABB 2CDS653061R0405 BMS613B40 3P 40A 6kA 400V AC DIN Rail Miniature Circuit Breaker
ABB 2CDS653061R0325 BMS613B32 3P 32A 10kA 500V DC Miniature Circuit Breaker
ABB 2CDS653061R0105 BMS613B10 3P 10A 6kA 400V B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0405 BMS611B40 1P 40A 6kA B-Curve DIN Rail Miniature Circuit Breaker
ABB 2CDS651061R0205 BMS611B20 1P 20A 6kA B-Curve 230V AC Miniature Circuit Breaker
ABB 2CDS651061R0325 BMS611B32 1P 32A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0065 BMS611B06 1P 6A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0255 BMS611B25 1P 25A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0105 BMS611B10 1P 10A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS651061R0165 BMS611B16 1P 16A 6kA B-Curve Miniature Circuit Breaker
ABB 2CDS634031R0404 BMS314C40 4P 40A 3kA 400V AC DIN Rail Miniature Circuit Breaker
ABB 2CDS634031R0104 BMS314C10 4P 10A 3kA C-Curve 400V AC Miniature Circuit Breaker
ABB 2CDS634031R0634 BMS314C63 4P 63A 3kA C-Curve Miniature Circuit Breaker
ABB 2CDS634031R0164 BMS314C16 4P 16A 3kA C-Curve 400V AC Miniature Circuit Breaker
ABB 2CDS634031R0254 BMS314C25 4P 25A 3kA C-Curve Miniature Circuit Breaker
ABB 2CDS634031R0204 BMS314C20 4P 20A 3kA C-Curve 400V AC Miniature Circuit Breaker
ABB 2CDS634031R0504 BMS314C50 4P 50A 3kA 400V DIN Rail Miniature Circuit Breaker (MCB)
ABB Basic M MCBs are entry-level DIN-rail miniature circuit breakers with a 3 kA breaking capacity. The range covers 6 A to 63 A in 1, 2, 3 and 4 poles, with more than 80 products. Stoklink ships worldwide from Turkey and quotes volumes on request.
What's in this range
- BMS311, BMS313 and BMS314 types for 1P, 3P and 4P circuits.
- B and C curve versions at 230 V and 400 V AC.
- For higher fault levels see ABB System pro M compact S200 MCBs.
How to choose
- 3 kA breaking capacity suits only installations with a low prospective short-circuit current. Check it first.
- Select the curve from the load: B for resistive circuits, C for general loads.
- Select the rating from the cable and the pole count from the supply system.
FAQ
Where is a 3 kA MCB acceptable?
In small installations where the calculated fault current at the board is below 3 kA. Higher fault levels need a 6 kA or 10 kA breaker.
What do the letters in BMS311C32 mean?
BMS311 is the series and pole count, C is the curve and 32 is the rated current in amperes.
Can I order Basic M breakers in bulk?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.