- Home
- All Products
- Siemens 6XV1878-5HE30 SIMATIC NET IE TP Cord M12-180/M12-180 0.3m Industrial Network Cable Siemens 6XV1878-5HE30 SIMATIC NET IE TP Cord M12-180/M12-180 0.3m Industrial Network Cable
Siemens 6XV1878-5HE30 SIMATIC NET IE TP Cord M12-180/M12-180 0.3m Industrial Network Cable
Get Quote
- Description
The Siemens 6XV1878-5HE30 is a preassembled IE TP Cord M12-180/M12-180, a 0.3 m Industrial Ethernet patch cord with two X-coded M12 connectors for connecting stations such as SCALANCE W or XP-200. Rated 100 Ω impedance with IP65/IP67 protection and PoE/PoE+/PoE++ support, it operates from -30 to +80 °C and meets Cat6A structured-cabling performance in a flexible PUR sheath.
Technical Specifications
| Order Number (MLFB) | 6XV1878-5HE30 |
| EAN | 4019169856270 |
| Brand | Siemens |
| Series | SIMATIC NET |
| Product Type Designation | IE TP Cord M12-180/M12-180 |
| Product Description | Flexible plug-in cable (8-wire), prefabricated with two IE FC M12 connectors 4x2, X-coded |
| Suitability | Connecting Industrial Ethernet stations with an M12 interface, e.g. SCALANCE W and XP-200 |
| Cable Designation | S/FTP |
| Cable Length | 0.3 m |
| Number of Electrical Connections | 2 |
| Attenuation at 10 MHz (max) | 0.086 dB/m |
| Attenuation at 100 MHz (max) | 0.28 dB/m |
| Attenuation at 300 MHz (max) | 0.402 dB/m |
| Attenuation at 600 MHz (max) | 0.735 dB/m |
| Impedance (1-100 MHz) | 100 Ω |
| Near-End Crosstalk per Length at 100 MHz | 0.724 dB/m |
| Near-End Crosstalk per Length at 300 MHz | 0.653 dB/m |
| Near-End Crosstalk per Length at 600 MHz | 0.608 dB/m |
| Coupling Loss at 30-100 MHz (min) | 80 dB |
| Loop Resistance per Length (max) | 290 mΩ/m |
| Insulation Resistance Coefficient | 5000 GΩ·m |
| Operating Voltage (RMS) | 80 V |
| NVP Value | 68 percent |
| Number of Electrical Cores | 8 |
| Shield Design | S/FTP, overlapped aluminum-clad foil with braided tinned-copper shield |
| Conductor Diameter (AWG26) | 0.48 mm |
| Wire Insulation Diameter | 1 mm |
| Inner Sheath Diameter | 5.4 mm |
| Cable Sheath Diameter | 6.5 mm |
| Sheath Diameter Tolerance | 0.3 mm |
| Wire Insulation Material | Polyethylene (PE) |
| Cable Sheath Material | PUR |
| Data Wire Colors | White/blue, white/orange, white/green, white/brown |
| Cable Sheath Color | Green |
| Bending Radius, Single Bend (min) | 32.5 mm |
| Bending Radius, Multiple Bends (min) | 65 mm |
| Maximum Tensile Load | 100 N |
| Weight per Length | 45 kg/km |
| Net Weight | 0.06 kg |
| Plug Interlock | Screwed |
| Plug-In Connection Design | M12-180 |
| Connector Coding | M12, X-coded |
| Operating Temperature | -30 to +80 °C |
| Storage Temperature | -40 to +80 °C |
| Transport Temperature | -40 to +80 °C |
| Installation Temperature | -40 to +80 °C |
| Fire Behavior | Flame resistant per IEC 60332-1-2, smoke density per IEC 61034 |
| Chemical Resistance to Mineral Oil | Oil resistant per DIN EN 60811-2-1 |
| Chemical Resistance to Grease | Conditional resistance |
| Chemical Resistance to Water | Conditional resistance |
| UV Resistance | Resistant |
| Protection Class IP | IP65, IP67 |
| Halogen-Free | Yes, per IEC 60754-1, IEC 61034 |
| PoE / PoE+ / PoE++ Capability | Yes |
| Silicone-Free | Yes |
| UL/ETL Listing (300 V) | AWM Style 21815, Wiring Harness |
| Certificate of Suitability | ISO/IEC 11801-1, IEC 61035 |
| Structured Cabling Standard | Cat6A |
| Country of Origin | Germany |
Certifications & Standards
- EAC
- CE
- RoHS
Selection Notes
Pick the 0.3 m cord for the shortest device-to-device hop — for example, linking two adjacent SCALANCE W access points on the same panel — where its 100 Ω impedance and 0.28 dB/m attenuation at 100 MHz add negligible loss. All three M12-180/M12-180 lengths in this family share the identical S/FTP shield, IP65/IP67 rating, and PoE++ support, so move to the 0.5 m or 1 m cord only when the physical mounting distance between the two M12 ports exceeds this reach.