- Description
The Siemens 6XV1875-5UH10 is a preassembled SCALANCE M/W antenna connection cable built for railway applications, with N-Connect and SMA male connectors in a 1 m length rated 50 Ω across 0-6000 MHz. The RADOX-sheathed cable withstands -30 to +100 °C and carries IP67 protection when plugged in, with EN 45545-2 fire-protection compliance for rolling-stock installation.
Technical Specifications
| Order Number (MLFB) | 6XV1875-5UH10 |
| EAN | 4019169855587 |
| Brand | Siemens |
| Series | SCALANCE M |
| Product Type Designation | Antenna connection cable, N-Connect/SMA plug/plug |
| Suitability | Connecting an antenna or Rcoax cable to SCALANCE M/W, railway applications |
| Cable Length | 1 m |
| Number of Electrical Connections | 2 |
| Type of Electrical Connection | N-Connect/SMA male/male |
| Transmission Frequency | 0 - 6000 MHz |
| Attenuation at 2.4 GHz (typical) | 0.47 dB/m |
| Attenuation at 5.2 GHz (typical) | 0.77 dB/m |
| Attenuation at 5.85 GHz (typical) | 0.83 dB/m |
| Impedance | 50 Ω |
| Capacitance per Length (at 1 kHz) | 80.2 pF/m |
| Relative Propagation Speed | 83 percent |
| Inner Conductor Diameter | 1.4 mm |
| Dielectric Diameter | 3.8 mm |
| Cable Sheath Diameter | 5.5 mm |
| Sheath Diameter Tolerance | 0.1 mm |
| Inner Conductor Material | Cu, silver plated |
| Dielectric Material | SPEX |
| Cable Sheath Material | RADOX |
| Cable Sheath Color | Black |
| Bending Radius, Single Bend (min) | 25 mm |
| Bending Radius, Multiple Bends (min) | 90 mm |
| Number of Bending Cycles | 50 |
| Weight per Length | 47.8 kg/km |
| Net Weight | 0.1 kg |
| Operating Temperature | -30 to +100 °C |
| Storage Temperature | -30 to +100 °C |
| Transport Temperature | -30 to +100 °C |
| Protection Class IP | IP67, when plugged in |
| Halogen-Free | Yes |
| Silicone-Free | Yes |
| Fire Protection Standard | NF F 16-101 |
| Smoke Emission Standard | EN 61034-2 |
| Flame Resistance Standard | EN 60332-1-2, IEC 60332-3-22, EN 50305 9.1.2 |
| Toxic Gas Emission Standard | NF-X 70-100 |
| Country of Origin | Germany |
Certifications & Standards
- RoHS
- EN 45545-2
Selection Notes
Choose the UH-series over the standard 6XV1875-5LH cable whenever the installation must meet railway fire and smoke standards — this variant adds EN 45545-2 compliance, NF F 16-101 fire protection, and an IP67-rated, RADOX-sheathed construction rated to -30…+100 °C, none of which the general-purpose SCALANCE M antenna cable carries. At 1 m, it delivers the lowest attenuation in the railway family, about 0.47 dB per meter at 2.4 GHz; pick the 2 m or 5 m version only when the physical routing distance between the SCALANCE M/W unit and the antenna requires it.