- Home
- All Products
- Siemens 6XV1870-3QN50 SIMATIC NET IE TP Cord RJ45/RJ45 Cat6a 50 m Industrial Network Cable Siemens 6XV1870-3QN50 SIMATIC NET IE TP Cord RJ45/RJ45 Cat6a 50 m Industrial Network Cable
Siemens 6XV1870-3QN50 SIMATIC NET IE TP Cord RJ45/RJ45 Cat6a 50 m Industrial Network Cable
Get Quote
- Description
The Siemens 6XV1870-3QN50 is a 50 m SIMATIC NET Industrial Ethernet TP Cord with two factory-assembled RJ45 connectors, built to Cat6a structured cabling standards rated up to 600 MHz. Its S/FTP shielded 4x2 design carries PoE, PoE+, and PoE++ power alongside 10GBASE-T data on the same run, holding loop resistance to 290 mΩ/m maximum and coupling loss above 70 dB.
Technical Specifications
| SKU | 6XV1870-3QN50 |
| EAN | 4019169855327 |
| Brand | Siemens |
| Series | SIMATIC NET |
| Product Type Designation | IE TP Cord RJ45/RJ45, 4x2 |
| Cable Designation | S/FTP, LI 02YSCH 4x2x0,15 PIMF GN FRNC |
| Wire Length | 50 m |
| Number of Electrical Connections | 2 |
| Structured Cabling Standard | Cat6A |
| Attenuation at 10 MHz (max) | 0.086 dB/m |
| Attenuation at 100 MHz (max) | 0.28 dB/m |
| Attenuation at 300 MHz (max) | 0.501 dB/m |
| Attenuation at 600 MHz (max) | 0.735 dB/m |
| Impedance (1-100 MHz) | 100 Ω |
| Impedance (10-600 MHz) | 100 Ω |
| Impedance Tolerance (1-100 MHz) | 15% |
| Impedance Tolerance (10-600 MHz) | 10% |
| Coupling Loss at 30-100 MHz (min) | 70 dB |
| Transfer Impedance at 10 MHz | 10 mΩ/m |
| Loop Resistance (max) | 290 mΩ/m |
| Operating Voltage (RMS) | 80 V |
| NVP Value | 80% |
| Number of Electrical Cores | 8 |
| Shield Design | S/FTP, overlapped aluminum-clad foil, tinned copper braided shield |
| Conductor Diameter (AWG26) | 0.5 mm |
| Cable Sheath Outer Diameter | 6.2 mm |
| Wire Insulation Material | polyethylene (PE) |
| Cable Sheath Material | FRNC |
| Cable Sheath Color | green |
| Bending Radius, Single Bend (min) | 31 mm |
| Bending Radius, Multiple Bends (min) | 43.5 mm |
| Weight per Length | 50 kg/km |
| Connector Type | RJ45 |
| Plug-in Connection Design | RJ45-180 |
| Ambient Temperature, Operation | -25 ... +80 °C |
| Ambient Temperature, Storage | -25 ... +80 °C |
| Ambient Temperature, Fixed Installation | -40 ... +80 °C |
| Fire Behavior | flame resistant per IEC 60332-1-2, EN 60332-3-24 |
| Burning Behaviour Class (EN 13501-6) | Eca |
| Protection Class | IP20 |
| Halogen-Free | Yes |
| PoE Capability | Yes |
| PoE+ Capability | Yes |
| PoE++ Capability | Yes |
| Test Voltage AC, Core-to-Core | 500 V |
| Test Voltage AC, Core-Shield | 1500 V |
| Country of Origin | HU |
| Net Weight | 0.498 kg |
Certifications & Standards
- EAC
- UL
- RoHS
Selection Notes
At 50 m this is the longest pre-terminated cord in the TP Cord series, useful for switch-to-device runs that would otherwise need a coupler and a second cord segment. The 0.735 dB/m attenuation at 600 MHz and ±10% impedance tolerance across 10–600 MHz keep the full Cat6a link within spec for 10GBASE-T at this length. Pick a shorter cord from the series whenever the physical route is well under 50 m to avoid coiling and securing excess slack in the cabinet.