How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
The Siemens 6GK1562-4AA00 CP 5624 is a PCI Express x1 (3.3 V) communications processor with both a DP master and a DP device connection to PROFIBUS on two separate 9-pin Sub-D ports, supplied with a configuration tool and DP-Base software including a DP-RAM interface, PG protocol, and FDL protocol as a single-installation runtime license, class A.
The second RS 485 port is the reason to pick this card over the single-port CP 5623: it runs an independent DP master on one port and a DP device connection (244-byte I/O) on the other, from the same PC. Master capacity and DPV0/DPV1/DPV2 support match the CP 5623 exactly, so choose this card specifically when the PC also needs to appear as a slave on a second PROFIBUS network rather than only mastering one.
PC stations that both master a PROFIBUS DP network and act as a DP device on a separate PROFIBUS segment, such as a gateway or supervisory PC bridging two independent bus systems.
| product type designation | CP 5624 communications processor CP 5624 PCI Express X1 (3. 3 V) with master and device connection to PB; including configuration tool and DP Base software: DP- RAM interface for DP master including PG and FDL protocol, single license for 1 installation, runtime software, class A; operating system support, see SIMATIC NET software. |
|---|---|
| product brand name | SIMATIC NET |
| transfer rate: at the 1st interface / according to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
|---|---|
| transfer rate: at the 2nd interface / according to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
| number of electrical connections: at the 1st interface / according to PROFIBUS | 1 |
|---|---|
| number of electrical connections: at the 2nd interface / according to PROFIBUS | 1 |
| type of electrical connection: at the 1st interface / according to PROFIBUS | 9-pin Sub-D socket (RS 485) |
| type of electrical connection: at the 2nd interface / according to PROFIBUS | 9-pin Sub-D socket (RS 485) |
| type of electrical connection: of the backplane bus | PCI Express x1 |
| Part number | 6GK1562-4AA00 |
|---|---|
| Type designation | CP 5624 communications processor CP 5624 PCI Express X1 (3. 3 V) with master and device connection to PB; including configuration tool and DP Base software: DP- RAM interface for DP master including PG and FDL protocol, single license for 1 installation, runtime software, class A; operating system support, see SIMATIC NET software. |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4019169188593 |
| ETIM class | EC001423 |
| eCl@ss | 27242208 |
| type of voltage / of the supply voltage | DC |
|---|---|
| supply voltage: 1 / from backplane bus | 3.3 V |
| supply voltage: 2 / from backplane bus | 12 V |
| relative symmetrical tolerance / at DC: at 3.3 V | 9% |
| relative symmetrical tolerance / at DC: at 12 V | 8% |
| consumed current: 1 / from backplane bus / at DC / maximum | 0.75 A |
| consumed current: 2 / from backplane bus / at DC / maximum | 0.3 A |
| power loss [W] | 6.1 W |
| ambient temperature: during operation | 5 ... 60 °C |
|---|---|
| ambient temperature: during storage | -20 ... +60 °C |
| ambient temperature: during transport | -20 ... +60 °C |
| relative humidity / at 25 °C / without condensation / during operation / maximum | 85 % |
| protection class IP | IP00 |
| module format | PCI Express x1 (half length) |
|---|---|
| width | 18 mm |
| height | 112 mm |
| depth | 168 mm |
| number of plug-in cards of same design / plug-in / per PC station | 4 |
|---|---|
| number of units / note | FMS-5613 supports up to two CP 5603 / CP 5613 A2 / CP 5614 A2 / CP 5623 / CP 5624 processors |
| software / for open communication / by means of SEND/RECEIVE / required | FDL driver included in scope of delivery of the CP |
|---|---|
| number of possible connections / for open communication / by means of SEND/RECEIVE / maximum | 80 |
| software / for DP master function / required | No |
|---|---|
| service / as DP master: DPV0 | Yes |
| service / as DP master: DPV1 | Yes |
| service / as DP master: DPV2 | Yes |
| number of DP devices / on DP master / operable | 124 |
| data volume: of the address range of the inputs / as DP master / total | 30256 byte |
| data volume: of the address range of the outputs / as DP master / total | 30256 byte |
| data volume: of the address range of the inputs / per DP device | 244 byte |
| data volume: of the address range of the outputs / per DP device | 244 byte |
| data volume: of the address range of the diagnostic data / per DP device | 244 byte |
| software / for DP device function / required | No |
| service / as DP device: DPV0 | Yes |
| service / as DP device: DPV1 | Yes |
| data volume: of the address range of the inputs / as DP device / total | 244 byte |
| data volume: of the address range of the outputs / as DP device / total | 244 byte |
| software / for FMS communication / required | Yes, FMS-5613 |
|---|---|
| number of possible connections / for FMS connection / maximum | 40 |
| software / for S7 communication / required | Yes, HARDNET-PB S7 (S7-5613) |
|---|---|
| number of possible connections / for S7/PG communication / maximum | 50 |
| number of active connections / with multi-protocol mode | 50 |
|---|---|
| number of configurable connections / per PC station | 207 |
| configuration software / required | Included in scope of supply |
|---|
| product function: port diagnostics | Yes |
|---|
| Environmental Product Declaration | Yes |
|---|---|
| global warming potential [CO2 eq]: total | 200.03 kg |
| global warming potential [CO2 eq]: during manufacturing | 33.2 kg |
| global warming potential [CO2 eq]: during operation | 166.77 kg |
| global warming potential [CO2 eq]: after end of life | 0.06 kg |
| Net weight | 0.006 kg |
|---|---|
| Package dimensions | 168 × 18 × 112 mm |
| Country of origin | DE |
| Shipping weight | 0.506 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CP 5624 communications processor CP 5624 PCI Express X1 (3. 3 V) with master and device connection to PB; including configuration tool and DP Base software: DP- RAM interface for DP master including PG and FDL protocol, single license for 1 installation, runtime software, class A; operating system support, see SIMATIC NET software. is 0.75 A.
The tariff (HS) code on file for CP 5624 communications processor CP 5624 PCI Express X1 (3. 3 V) with master and device connection to PB; including configuration tool and DP Base software: DP- RAM interface for DP master including PG and FDL protocol, single license for 1 installation, runtime software, class A; operating system support, see SIMATIC NET software. is 85176200.
The EAN (GTIN) of CP 5624 communications processor CP 5624 PCI Express X1 (3. 3 V) with master and device connection to PB; including configuration tool and DP Base software: DP- RAM interface for DP master including PG and FDL protocol, single license for 1 installation, runtime software, class A; operating system support, see SIMATIC NET software. is 4019169188593.
CP 5624 communications processor CP 5624 PCI Express X1 (3. 3 V) with master and device connection to PB; including configuration tool and DP Base software: DP- RAM interface for DP master including PG and FDL protocol, single license for 1 installation, runtime software, class A; operating system support, see SIMATIC NET software. ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.