How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
The Siemens 6ES7677-2SB42-0GM0 is a SIMATIC ET 200SP Open Controller running CPU 1515SP PC2 F with an integrated HMI licensed for 2048 PowerTags. It pairs an S7-1500 Failsafe Software Controller CPU 1505SP F V2x with WinCC Runtime Advanced V17 on 8 GB RAM and a 128 GB CFast card preloaded with Windows 10 IoT Enterprise LTSC 2019 64-bit.
The 2048 PowerTags license lifts the WinCC Runtime Advanced tag ceiling fourfold over the 512-tag version, which matters once the application spans multiple HMI screens or a wider set of monitored I/O points. Choose this variant over the 512 PowerTags version when the project's tag count is already near or past 512, since upgrading a license later costs more than buying the larger one up front. The Failsafe Software Controller CPU 1505SP F V2x and WinCC Runtime Advanced V17 share the same Intel Atom E3940 processor and 8 GB RAM as the smaller-license unit, so the extra tag headroom comes at identical hardware cost and the same 55 W active power draw.
| Product type designation | CPU 1515SP PC2 F |
|---|---|
| HW functional status | from FS04 |
| Firmware version | V21.9 |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V17 |
| Installed software: Visualization | WinCC Runtime Advanced V17 |
| Installed software: Control | S7-1500 Software Controller CPU 1505SP F |
| via dataset | Yes |
|---|
| Mode selector switch | 1 |
|---|
| Part number | 6ES7677-2SB42-0GM0 |
|---|---|
| Type designation | CPU 1515SP PC2 F |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623409908 |
| ETIM class | EC001603 |
| eCl@ss | 27242607 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 5 ms |
| Current consumption (rated value) | 1.8 A; Full processor load, incl. ET 200SP modules and using USB |
|---|---|
| Current consumption (in no-load operation), typ. | 0.5 A |
| Current consumption, max. | 2.9 A |
| I2t | 0.426 A2·s; with starting current inrush |
| Active power input, max. | 55 W; incl. ET 200SP modules and using USB |
|---|---|
| Infeed power to the backplane bus | 8.75 W |
| Power loss, typ. | 15 W; without ET 200SP modules and without using USB |
|---|
| Processor type | Intel Atom E3940, 1.6 GHz, 4 cores |
|---|
| Type of memory | DDR3L |
|---|---|
| Main memory | 8 GB RAM |
| CFast memory card | Yes; 128 GB flash memory |
| SIMATIC memory card required | No |
| Work memory: integrated (for program) | 1.5 Mbyte |
| Work memory: integrated (for data) | 5 Mbyte |
| Work memory: integrated (for CPU function library of CPU Runtime) | 20 Mbyte |
| Load memory: integrated (on PC mass storage) | 320 Mbyte |
| Backup: with UPS | Yes; all memory areas declared retentive |
| Backup: with non-volatile memory | Yes |
| Number of elements (total) | 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements |
|---|---|
| DB: Number, max. | 5 999; Number range: 1 to 65535 |
| DB: Size, max. | 5 Mbyte |
| FB: Number, max. | 5 998; Number range: 1 to 65535 |
| FB: Size, max. | 1 024 kbyte |
| FC: Number, max. | 5 999; Number range: 1 to 65535 |
| FC: Size, max. | 1 024 kbyte |
| OB: Size, max. | 1 024 kbyte |
| OB: Number of free cycle OBs | 100 |
| OB: Number of time alarm OBs | 20 |
| OB: Number of delay alarm OBs | 20 |
| OB: Number of cyclic interrupt OBs | 20 |
| OB: Number of process alarm OBs | 50 |
| OB: Number of DPV1 alarm OBs | 3 |
| OB: Number of isochronous mode OBs | 1 |
| OB: Number of technology synchronous alarm OBs | 2 |
| OB: Number of startup OBs | 100 |
| OB: Number of asynchronous error OBs | 4 |
| OB: Number of synchronous error OBs | 2 |
| OB: Number of diagnostic alarm OBs | 1 |
| Nesting depth: per priority class | 24; Up to 8 possible for F-blocks |
| S7 counter: Number Retentivity | 2 048 |
|---|---|
| S7 counter: adjustable | Yes |
| IEC counter: Number Retentivity | Any (only limited by the main memory) |
| IEC counter: adjustable | Yes |
| S7 timer: Number Retentivity | 2 048 |
| S7 timer: adjustable | Yes |
| IEC timer: Number Retentivity | Any (only limited by the main memory) |
| IEC timer: adjustable | Yes |
| Retentive data area (incl. timers, counters, flags), max. | 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes |
|---|---|
| Flag: Size, max. | 16 kbyte |
| Flag: Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks: Retentivity adjustable | Yes |
| Data blocks: Retentivity preset | No |
| Local data: per priority class, max. | 64 kbyte; max. 16 KB per block |
| Number of IO modules | 8 192 |
|---|---|
| I/O address area: Inputs | 32 kbyte; All inputs are in the process image |
| I/O address area: Outputs | 32 kbyte; All outputs are in the process image |
| Subprocess images: Number of subprocess images, max. | 32 |
| Integrated power supply | Yes |
|---|---|
| Number of distributed IO systems | 20 |
| Number of DP masters: Via CM | 1 |
| Number of IO Controllers: via PC interfaces | 1 |
| Rack: Modules per rack, max. | 64; CPU 1515SP PC + 64 modules + server module |
| Rack: Quantity of operable ET 200SP modules, max. | 64 |
| Rack: Quantity of operable ET 200AL modules, max. | 16 |
| Rack: Number of lines, max. | 1 |
| PtP CM: Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
| Clock: Type | Hardware clock |
|---|---|
| Clock: Hardware clock (real-time) | Yes; Resolution: 1 s |
| Clock: Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Clock: Deviation per day, max. | 10 s; Typ.: 2 s |
| Clock synchronization: supported | Yes |
| Clock synchronization: to DP, master | Yes |
| Clock synchronization: on Ethernet via NTP | Yes |
| Clock synchronization: on Windows clock, device | Yes |
| Number of industrial Ethernet interfaces | 2 |
|---|---|
| Number of PROFINET interfaces | 1 |
| Number of PROFIBUS interfaces | 1 |
| Number of RS 485 interfaces | 1; Via CM DP module |
| Number of USB interfaces | 4; 2x USB 2.0, 2x USB 3.0 on front side |
| Number of SD card slots | 1 |
| Video interfaces: Graphics interface | 1x DisplayPort |
| Interface type | PROFINET |
|---|---|
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Number of connections | 88 |
| Interface types: RJ 45 (Ethernet) | Yes; Via BusAdapter BA 2x RJ45 |
| Interface types: Transmission rate, max. | 100 Mbit/s |
| Interface types: Industrial Ethernet status LED | Yes |
| Interface types: Number of ports | 2 |
| Interface types: integrated switch | Yes |
| Interface types: BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC, |
| Protocols: IP protocol | Yes; IPv4 |
| Protocols: PROFINET IO Controller | Yes |
| Protocols: PROFINET IO Device | Yes |
| Protocols: SIMATIC communication | Yes |
| Protocols: Open IE communication | Yes; Optionally also encrypted |
| Protocols: Web server | Yes |
| PROFINET IO Controller Services: Isochronous mode | Yes |
| PROFINET IO Controller Services: shortest clock pulse | 500 µs |
| PROFINET IO Controller Services: IRT | Yes |
| PROFINET IO Controller Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Controller Services: PROFIenergy | Yes |
| PROFINET IO Controller Services: Prioritized startup | Yes; max. 32 PROFINET devices; if you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205) |
| PROFINET IO Controller Services: Number of connectable IO Devices, max. | 128 |
| PROFINET IO Controller Services: Of which IO devices with IRT, max. | 64 |
| PROFINET IO Controller Services: of which in line, max. | 64 |
| PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| PROFINET IO Controller Services: IO Devices changing during operation (partner ports), supported | Yes |
| PROFINET IO Controller Services: Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller Services: Updating times Update time for IRT | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET IO Controller Services: for send cycle of 500 µs | 500 µs to 8 ms |
| PROFINET IO Controller Services: for send cycle of 1 ms | 1 ms to 16 ms |
| PROFINET IO Controller Services: for send cycle of 2 ms | 2 ms to 32 ms |
| PROFINET IO Controller Services: for send cycle of 4 ms | 4 ms to 64 ms |
| PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT | Update time = set "odd" send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs |
| PROFINET IO Controller Services: for send cycle of 4 ms Address area | 4 ms to 512 ms |
| PROFINET IO Controller Services: Inputs, max. | 8 kbyte |
| PROFINET IO Controller Services: Outputs, max. | 8 kbyte |
| PROFINET IO Device Services: Isochronous mode | No |
| PROFINET IO Device Services: shortest clock pulse | 500 µs |
| PROFINET IO Device Services: IRT | Yes |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Device Services: PROFIenergy | Yes |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 4 |
| PROFINET IO Device Services: Asset management record | Yes |
| Interface type | Integrated Ethernet interface |
|---|---|
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Interface types: RJ 45 (Ethernet) | Yes; Integrated |
| Interface types: Transmission rate, max. | 1 000 Mbit/s |
| Interface types: Industrial Ethernet status LED | No |
| Interface types: Number of ports | 1 |
| Interface type | PROFIBUS with CM DP |
|---|---|
| Number of connections | 44 |
| Interface types: RS 485 | Yes |
| Protocols: PROFIBUS DP master | Yes |
| Protocols: PROFIBUS DP device | Yes |
| Protocols: SIMATIC communication | Yes |
| PROFIBUS DP master: max. number of DP devices Services | 125 |
| PROFIBUS DP master: Equidistance | No |
| PROFIBUS DP master: Isochronous mode Address area | No |
| PROFIBUS DP master: Inputs, max. | 8 kbyte |
| PROFIBUS DP master: Outputs, max. | 8 kbyte |
| RS 485: Transmission rate, max. | 12 Mbit/s |
|---|
| PROFIsafe | Yes |
|---|---|
| Number of connections: Number of connections, max. | 88 |
| Number of connections: Number of connections reserved for ES/HMI/web | 10 |
| Number of connections: Number of S7 routing paths | 16 |
| Redundancy mode: PROFINET system redundancy (S2) | No |
| Redundancy mode: PROFINET system redundancy (R1) Media redundancy | No |
| Redundancy mode: MRP | Yes |
| Redundancy mode: MRP interconnection, supported | Yes |
| Redundancy mode: MRPD | Yes |
| Redundancy mode: Switchover time on line break, typ. | 200 ms |
| Redundancy mode: Number of stations in the ring, max. | 50 |
| SIMATIC communication: PG/OP communication | Yes |
| SIMATIC communication: S7 routing | Yes |
| SIMATIC communication: S7 communication, as server | Yes |
| SIMATIC communication: S7 communication, as client | Yes |
| SIMATIC communication: User data per job, max. | 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: Data length, max. | 64 kbyte |
| Open IE communication: ISO-on-TCP (RFC1006) | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: DCP | Yes |
| Open IE communication: LLDP | Yes |
| Web server: HTTP | Yes; Via Windows and PROFINET interface |
| Web server: HTTPS | Yes; Via Windows and PROFINET interface |
| OPC UA: Runtime license required | Yes; "Small" license required |
| OPC UA: OPC UA Client | Yes; From SW CPU 1505SP V2.6 |
| OPC UA: OPC UA Server | Yes; Data access (read, write, subscribe), runtime license required |
| OPC UA: Application authentication | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| OPC UA: Security policies | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| OPC UA: User authentication | Yes; "anonymous" or by user name & password |
| Further protocols: MODBUS | Yes; MODBUS TCP |
| Number of login stations for message functions, max. | 32 |
|---|---|
| Program alarms | Yes |
| Number of configurable program messages, max. | 10 000 |
| Number of simultaneously active program alarms | 1 000 |
| Number of program alarms | 1 000 |
| Number of alarms for system diagnostics | 200 |
| Number of alarms for motion technology objects | 160 |
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems |
|---|---|
| Status block | Yes; up to 8 simultaneously |
| Single step | No |
| Number of breakpoints | 8 |
| Status/control: Status/control variable | Yes |
| Status/control: Variables | Inputs, outputs, memory bits, DB, times, counters |
| Number of variables, max.: of which status variables, max. | 200 |
| Number of variables, max.: of which control variables, max. | 200 |
| Forcing: Forcing | Yes |
| Forcing: Forcing, variables | Inputs, outputs |
| Forcing: Number of variables, max. | 200 |
| Diagnostic buffer: present | Yes |
| Diagnostic buffer: Number of entries, max. | 1 000 |
| Diagnostic buffer: of which powerfail-proof | 300 |
| Traces: Number of configurable Traces | 4 |
| Traces: Memory size per trace, max. | 512 kbyte |
| Diagnostics indication LED: RUN/STOP LED | Yes |
|---|---|
| Diagnostics indication LED: ERROR LED | Yes |
| Diagnostics indication LED: MAINT LED | Yes |
| Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
|---|---|
| Number of available Motion Control resources for technology objects | 2 400 |
| Required Motion Control resources: per speed-controlled axis | 40; per axis |
| Required Motion Control resources: per positioning axis | 80; per axis |
| Required Motion Control resources: per synchronous axis | 160; per axis |
| Required Motion Control resources: per external encoder | 80; per external encoder |
| Required Motion Control resources: per output cam | 20; per cam |
| Required Motion Control resources: per cam track | 160; per cam track |
| Required Motion Control resources: per probe | 40; per probe |
| Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) | 15 |
| Controller: PID_Compact | Yes; Universal PID controller with integrated optimization |
| Controller: PID_3Step | Yes; PID controller with integrated optimization for valves |
| Controller: PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring: High-speed counter | Yes |
| CE mark | Yes |
|---|---|
| CSA approval | Yes |
| cULus | Yes |
| FM approval | Yes |
| RCM (formerly C-TICK) | Yes |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 432 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 73.8 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 365 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -6.71 kg |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | PLe |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) | SIL 3 |
| Highest safety class achievable in safety mode: Low demand mode: PFDavg in accordance with SIL3 | < 2.00E-05 |
| Highest safety class achievable in safety mode: High demand/continuous mode: PFH in accordance with SIL3 | < 1.00E-09 1/h |
| Ambient temperature during operation: min. | -20 °C |
|---|---|
| Ambient temperature during operation: horizontal installation, min. | -20 °C |
| Ambient temperature during operation: vertical installation, min. | -20 °C |
| Ambient temperature during storage/transportation: min. | -40 °C |
| Ambient temperature during storage/transportation: max. | 70 °C |
| Vibrations: Operation, tested according to IEC 60068-2-6 | Yes |
| Vibrations: Transport, tested acc. to IEC 60068-2-6 | Yes |
| Shock testing: tested according to IEC 60068-2-6 | Yes |
| Shock testing: tested according to IEC 60068-2-27 | Yes |
| Shock testing: tested according to IEC 60068-2-29 | Yes |
| Shock testing: Storage/transport, tested acc. to IEC 60068-2-27 | Yes |
| pre-installed operating system | Windows 10 IoT Enterprise 2019 LTSC, 64 bit, MUI |
|---|
| Programming Programming language: LAD | Yes; incl. failsafe |
|---|---|
| Programming Programming language: FBD | Yes; incl. failsafe |
| Programming Programming language: STL | Yes |
| Programming Programming language: SCL | Yes |
| Programming Programming language: CFC | No |
| Programming Programming language: GRAPH | Yes |
| Know-how protection: User program protection/password protection | Yes |
| Know-how protection: Copy protection | Yes |
| Know-how protection: Block protection | Yes |
| Access protection: protection of confidential configuration data | Yes |
| Access protection: Protection level: Write protection | Yes |
| Access protection: Protection level: Read/write protection | Yes |
| Access protection: Protection level: Write protection for Failsafe | Yes |
| Access protection: Protection level: Complete protection | Yes |
| Cycle time monitoring: lower limit | adjustable minimum cycle time |
| Cycle time monitoring: upper limit | adjustable maximum cycle time |
| Open Development interfaces: Size of ODK SO file, max. | 5.8 Mbyte |
| SD card | Optionally for additional mass storage |
|---|
| Width | 160 mm |
|---|---|
| Height | 117 mm |
| Depth | 75 mm |
| Weight, approx. | 0.83 kg |
|---|
| Net weight | 1.041 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.541 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CPU 1515SP PC2 F is 1.8 A.
The rated operational voltage of CPU 1515SP PC2 F is 24 V AC.
The tariff (HS) code on file for CPU 1515SP PC2 F is 85371091.
The EAN (GTIN) of CPU 1515SP PC2 F is 4047623409908.
CPU 1515SP PC2 F ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.