Part number
6ES7677-2DB42-0GB1
Model no
CPU 1515SP PC2
$3,990.50 On request Dispatch — · From TürkiyeGet a Quote
SIMATIC ET 200SP

Siemens 6ES7677-2DB42-0GB1 ET 200SP Open Controller CPU1515SP PC2 V3x Programmable Logic Controller

SIMATIC ET 200SP Open Controller CPU1515SP PC2, Intel Atom E3940, 8 GB RAM, 128 GB CFast.

Rated current
1.8 A
Rated operational voltage
24 V AC
Communication
PROFINET, PROFIBUS (via CM), RS 485 (via CM), 4x USB
Display
1x DisplayPort (no integrated screen)
EAN
4047623414094
Description

About the CPU 1515SP PC2

The Siemens 6ES7677-2DB42-0GB1 is a SIMATIC ET 200SP Open Controller, CPU1515SP PC2, running the newer S7-1500 Software Controller CPU 1505SP V3x on Windows 10 IoT Enterprise LTSC 2021. Firmware V31.1 raises the program work memory to 2 Mbyte and data memory to 7.5 Mbyte, with an 8 000-element CPU-blocks budget - both larger than the V2x baseline on the same Intel Atom E3940 hardware with 8 GB RAM and 128 GB CFast.

Certifications & Standards

  • CE
  • CSA
  • cULus
  • FM
  • RCM

Selection Notes

Choose the 6ES7677-2DB42-0GB1 over the V2x-based 6ES7677-2DB42-0GB0 when the program needs the larger 8 000-element block budget or the extra 16 ET 200AL modules the V3x firmware supports (82 modules per rack versus 64). LTSC 2021 also extends the Windows support window past the LTSC 2019 image used on the -0GB0/-0GK0/-0GL0/-0GM0 variants, which matters for long-running installations planning OS updates.

Applications

Fits new machine designs that want the longest available Windows LTSC support horizon together with the larger V3x memory and block limits, rather than matching an existing V2x fleet for uniformity.

Specification

Full specification

306 values · Last verified 01 Nov 2026

General information 8

Product type designation CPU 1515SP PC2
Firmware version V31.1
Product function: I&M data Yes; I&M0 to I&M3
Product function: Isochronous mode Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs
Product function: SysLog Yes
Engineering with: STEP 7 TIA Portal configurable/integrated from version V20 (FW V31.1) / V18 (FW V30.0) or higher
Installed software: Visualization No
Installed software: Control S7-1500 Software Controller CPU 1505SP

Configuration control 1

via dataset Yes

Control elements 1

Mode selector switch 1
Show all 306 specifications ↓ Show less ↑296 more values in Identification, Supply voltage, Input current, Power, Power loss, Processor, Storage, CPU-blocks, Counters, timers and their retentivity, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Interfaces, 1. Interface, 2. Interface, 3. Interface, Interface types, Protocols, S7 message functions, Test commissioning functions, Interrupts/diagnostics/status information, Supported technology objects, Standards, approvals, certificates, Ambient conditions, Operating systems, Configuration, Peripherals/Options, Version Classification, Logistics.

Identification 10

Part number 6ES7677-2DB42-0GB1
Type designation CPU 1515SP PC2
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4047623414094
ETIM class EC001603
eCl@ss 27242607

Supply voltage 5

Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering: Mains/voltage failure stored energy time 5 ms

Input current 4

Current consumption (rated value) 1.8 A; Full processor load, incl. ET 200SP modules and using USB
Current consumption (in no-load operation), typ. 0.5 A
Current consumption, max. 2.9 A
I2t 0.426 A2·s; with starting current inrush

Power 2

Active power input, max. 43 W; incl. ET 200SP modules and using USB
Infeed power to the backplane bus 8.75 W

Power loss 1

Power loss, typ. 16 W

Processor 1

Processor type Intel Atom E3940, 1.6 GHz, 4 cores

Storage 10

Type of memory DDR3L
Main memory 8 GB RAM
CFast memory card Yes; 128 GB flash memory
SIMATIC memory card required No
Work memory: integrated (for program) 2 Mbyte
Work memory: integrated (for data) 7.5 Mbyte
Work memory: integrated (for CPU function library of CPU Runtime) 20 Mbyte
Load memory: integrated (on PC mass storage) 320 Mbyte
Backup: with UPS Yes; all memory areas declared retentive
Backup: with non-volatile memory Yes

CPU-blocks 21

Number of elements (total) 8 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements
DB: Number, max. 7 999; Number range: 1 to 65535
DB: Size, max. 5 Mbyte
FB: Number, max. 7 998; Number range: 1 to 65535
FB: Size, max. 1 024 kbyte
FC: Number, max. 7 999; Number range: 1 to 65535
FC: Size, max. 1 024 kbyte
OB: Size, max. 1 024 kbyte
OB: Number of free cycle OBs 100
OB: Number of time alarm OBs 20
OB: Number of delay alarm OBs 20
OB: Number of cyclic interrupt OBs 20
OB: Number of process alarm OBs 50
OB: Number of DPV1 alarm OBs 3
OB: Number of isochronous mode OBs 1
OB: Number of technology synchronous alarm OBs 2
OB: Number of startup OBs 100
OB: Number of asynchronous error OBs 4
OB: Number of synchronous error OBs 2
OB: Number of diagnostic alarm OBs 1
Nesting depth: per priority class 24

Counters, timers and their retentivity 8

S7 counter: Number Retentivity 2 048
S7 counter: adjustable Yes
IEC counter: Number Retentivity Any (only limited by the main memory)
IEC counter: can be set Yes
S7 timer: Number Retentivity 2 048
S7 timer: adjustable Yes
IEC timer: Number Retentivity Any (only limited by the main memory)
IEC timer: can be set Yes

Data areas and their retentivity 6

Retentive data area (incl. timers, counters, flags), max. 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes
Flag: Size, max. 16 kbyte
Flag: Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks: Retentivity adjustable Yes
Data blocks: Retentivity preset No
Local data: per priority class, max. 64 kbyte; max. 16 KB per block

Address area 4

Number of IO modules 8 192
I/O address area: Inputs 32 kbyte; All inputs are in the process image
I/O address area: Outputs 32 kbyte; All outputs are in the process image
Subprocess images: Number of subprocess images, max. 32

Hardware configuration 9

Integrated power supply Yes
Number of distributed IO systems 20
Number of DP masters: Via CM 1
Number of IO Controllers: via PC interfaces 1
Rack: Modules per rack, max. 82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
Rack: Quantity of operable ET 200SP modules, max. 64
Rack: Quantity of operable ET 200AL modules, max. 16
Rack: Number of lines, max. 1
PtP CM: Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots

Time of day 8

Clock: Type Hardware clock
Clock: Hardware clock (real-time) Yes; Resolution: 1 s
Clock: Backup time 6 wk; At 40 °C ambient temperature, typically
Clock: Deviation per day, max. 10 s; Typ.: 2 s
Clock synchronization: supported Yes
Clock synchronization: to DP, master Yes; Via CM DP module
Clock synchronization: on Ethernet via NTP Yes
Clock synchronization: on Windows clock, device Yes

Interfaces 7

Number of industrial Ethernet interfaces 2
Number of PROFINET interfaces 1
Number of PROFIBUS interfaces 1; Via CM DP module
Number of RS 485 interfaces 1; Via CM DP module
Number of USB interfaces 4; 2x USB 2.0, 2x USB 3.0 on front side
Number of SD card slots 1
Video interfaces: Graphics interface 1x DisplayPort

1. Interface 51

Interface type PROFINET
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Number of connections 88
Interface types: RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45
Interface types: Transmission rate, max. 100 Mbit/s
Interface types: Industrial Ethernet status LED Yes
Interface types: Number of ports 2
Interface types: integrated switch Yes
Interface types: BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO device Yes
Protocols: SIMATIC communication Yes
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
Protocols: Media redundancy Yes
PROFINET IO Controller Services: Isochronous mode Yes
PROFINET IO Controller Services: Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
PROFINET IO Controller Services: shortest clock pulse 500 µs
PROFINET IO Controller Services: IRT Yes
PROFINET IO Controller Services: Dynamic Frame Packing (DFP) No
PROFINET IO Controller Services: PROFIenergy Yes
PROFINET IO Controller Services: Prioritized startup Yes; Max. 32 PROFINET devices
PROFINET IO Controller Services: Number of connectable IO Devices, max. 128
PROFINET IO Controller Services: Of which IO devices with IRT, max. 64
PROFINET IO Controller Services: of which in line, max. 64
PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. 8
PROFINET IO Controller Services: IO Devices changing during operation (partner ports), supported Yes
PROFINET IO Controller Services: Number of IO Devices per tool, max. 8
PROFINET IO Controller Services: Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
PROFINET IO Controller Services: PROFINET Security Class Update time for IRT 1
PROFINET IO Controller Services: for send cycle of 500 µs 500 µs to 8 ms
PROFINET IO Controller Services: for send cycle of 1 ms 1 ms to 16 ms
PROFINET IO Controller Services: for send cycle of 2 ms 2 ms to 32 ms
PROFINET IO Controller Services: for send cycle of 4 ms 4 ms to 64 ms
PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT Update time = set "odd" send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs
PROFINET IO Controller Services: for send cycle of 4 ms Address area 4 ms to 512 ms
PROFINET IO Controller Services: Inputs, max. 8 kbyte
PROFINET IO Controller Services: Outputs, max. 8 kbyte
PROFINET IO Device Services: Isochronous mode No
PROFINET IO Device Services: IRT Yes
PROFINET IO Device Services: Dynamic Frame Packing (DFP) No
PROFINET IO Device Services: PROFIenergy Yes; per user program
PROFINET IO Device Services: Prioritized startup Yes
PROFINET IO Device Services: Shared device Yes
PROFINET IO Device Services: Number of IO Controllers with shared device, max. 4
PROFINET IO Device Services: activation/deactivation of I-devices Yes; per user program
PROFINET IO Device Services: Asset management record Yes; per user program
PROFINET IO Device Services: PROFINET Security Class SNMP Configuration and DCP Read Only

2. Interface 8

Interface type Integrated Ethernet interface
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface types: RJ 45 (Ethernet) Yes; Integrated
Interface types: Transmission rate, max. 1 000 Mbit/s
Interface types: Industrial Ethernet status LED No
Interface types: Number of ports 1

3. Interface 11

Interface type PROFIBUS with CM DP
Number of connections 44
Interface types: RS 485 Yes
Protocols: PROFIBUS DP master Yes
Protocols: PROFIBUS DP device Yes
Protocols: SIMATIC communication Yes
PROFIBUS DP master: max. number of DP devices Services 125
PROFIBUS DP master: Equidistance No
PROFIBUS DP master: Isochronous mode Address area No
PROFIBUS DP master: Inputs, max. 8 kbyte
PROFIBUS DP master: Outputs, max. 8 kbyte

Interface types 1

RS 485: Transmission rate, max. 12 Mbit/s

Protocols 42

PROFIsafe No
Number of connections: Number of connections, max. 88
Number of connections: Number of connections reserved for ES/HMI/web 10
Number of connections: Number of S7 routing paths 16
Redundancy mode: PROFINET system redundancy (S2) No
Redundancy mode: PROFINET system redundancy (R1) Media redundancy No
Redundancy mode: Media redundancy Yes; only via BusAdapter
Redundancy mode: MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
Redundancy mode: MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
Redundancy mode: MRPD Yes; Requirement: IRT
Redundancy mode: Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
Redundancy mode: Number of stations in the ring, max. 50
SIMATIC communication: PG/OP communication Yes; encryption with TLS V1.3 pre-selected
SIMATIC communication: S7 routing Yes
SIMATIC communication: S7 communication, as server Yes
SIMATIC communication: S7 communication, as client Yes
SIMATIC communication: User data per job, max. 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes
Open IE communication: TCP/IP Yes
Open IE communication: Data length, max. 64 kbyte
Open IE communication: ISO-on-TCP (RFC1006) Yes
Open IE communication: UDP Yes
Open IE communication: UDP multicast Yes; Max. 5 multicast circuits
Open IE communication: DHCP Yes
Open IE communication: DNS Yes
Open IE communication: SNMP Yes
Open IE communication: DCP Yes
Open IE communication: LLDP Yes
Open IE communication: Encryption Yes; Optional
Web server: HTTP Yes; Standard and user pages
Web server: HTTPS Yes; Standard and user pages
web API: Number of sessions, max. 50
web API: number of simultaneous HTTP calls, max. 4
web API: HTTP request body, max. 131 072 byte
OPC UA: Runtime license required Yes; "Small" license required
OPC UA: OPC UA Client Yes; Data access (read, write), method call
OPC UA: Application authentication Yes
OPC UA: Security policies Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
OPC UA: User authentication Yes; "anonymous" or by user name & password
OPC UA: Number of connections, max. 10
OPC UA: Number of nodes of the client interfaces, recommended max. 2 000
Number of elements for one call of 300 OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.: Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20
Further protocols: MODBUS Yes; MODBUS TCP

S7 message functions 7

Number of login stations for message functions, max. 32
Program alarms Yes
Number of configurable program messages, max. 10 000
Number of simultaneously active program alarms 1 000
Number of program alarms 1 000
Number of alarms for system diagnostics 200
Number of alarms for motion technology objects 160

Test commissioning functions 17

Joint commission (Team Engineering) Yes; Parallel online access possible for up to 10 engineering systems
Status block Yes; up to 8 simultaneously
Single step Yes
Number of breakpoints 8
Profiling No
Status/control: Status/control variable Yes
Status/control: Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.: of which status variables, max. 200; per job
Number of variables, max.: of which control variables, max. 200; per job
Forcing: Forcing Yes
Forcing: Forcing, variables Peripheral inputs/outputs
Forcing: Number of variables, max. 200
Diagnostic buffer: present Yes
Diagnostic buffer: Number of entries, max. 1 000
Diagnostic buffer: of which powerfail-proof 300
Traces: Number of configurable Traces 4
Traces: Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information 3

Diagnostics indication LED: RUN/STOP LED Yes
Diagnostics indication LED: ERROR LED Yes
Diagnostics indication LED: MAINT LED Yes

Supported technology objects 14

Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER
Number of available Motion Control resources for technology objects 2 400
Required Motion Control resources: per speed-controlled axis 40
Required Motion Control resources: per positioning axis 80
Required Motion Control resources: per synchronous axis 160
Required Motion Control resources: per external encoder 80
Required Motion Control resources: per output cam 20
Required Motion Control resources: per cam track 160
Required Motion Control resources: per probe 40
Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) 30
Controller: PID_Compact Yes; Universal PID controller with integrated optimization
Controller: PID_3Step Yes; PID controller with integrated optimization for valves
Controller: PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring: High-speed counter Yes

Standards, approvals, certificates 5

CE mark Yes
CSA approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes

Ambient conditions 11

Ambient temperature during operation: min. -20 °C
Ambient temperature during operation: horizontal installation, min. -20 °C
Ambient temperature during operation: vertical installation, min. -20 °C
Ambient temperature during storage/transportation: min. -40 °C
Ambient temperature during storage/transportation: max. 70 °C
Vibrations: Operation, tested according to IEC 60068-2-6 Yes
Vibrations: Transport, tested acc. to IEC 60068-2-6 Yes
Shock testing: tested according to IEC 60068-2-6 Yes
Shock testing: tested according to IEC 60068-2-27 Yes
Shock testing: tested according to IEC 60068-2-29 Yes
Shock testing: Storage/transport, tested acc. to IEC 60068-2-27 Yes

Operating systems 1

pre-installed operating system Windows 10 IoT Enterprise 2021 LTSC

Configuration 18

Programming Programming language: LAD Yes
Programming Programming language: FBD Yes
Programming Programming language: STL Yes
Programming Programming language: SCL Yes
Programming Programming language: CFC No
Programming Programming language: GRAPH Yes
Know-how protection: User program protection/password protection Yes
Know-how protection: Copy protection Yes
Know-how protection: Block protection Yes
Access protection: protection of confidential configuration data Yes
Access protection: Protection level: Write protection Yes
Access protection: Protection level: Read/write protection Yes
Access protection: Protection level: Complete protection Yes
Access protection: User administration Yes; device-wide
Access protection: Number of users 100
Cycle time monitoring: lower limit adjustable minimum cycle time
Cycle time monitoring: upper limit adjustable maximum cycle time
Open Development interfaces: Size of ODK SO file, max. 5.8 Mbyte

Peripherals/Options 1

SD card Optionally for additional mass storage

Version Classification 4

eClass 16 27-24-26-07
ETIM 10 EC001603
IDEA 4 3565
UNSPSC 15 32-15-17-05

Logistics 6

Net weight 1.028 kg
Country of origin DE
Shipping weight 1.528 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7677-2DB42-0GB1

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • GDS support (certificate management)
  • CE mark
  • CSA approval
  • cULus
  • FM approval
  • RCM (formerly C-TICK)
Quick answers

Questions about the CPU 1515SP PC2

What is the rated current of CPU 1515SP PC2?

The rated current of CPU 1515SP PC2 is 1.8 A.

Which supply voltage is CPU 1515SP PC2 rated for?

The rated operational voltage of CPU 1515SP PC2 is 24 V AC.

What is the HS code of CPU 1515SP PC2 for customs?

The tariff (HS) code on file for CPU 1515SP PC2 is 85371091.

What is the EAN of CPU 1515SP PC2?

The EAN (GTIN) of CPU 1515SP PC2 is 4047623414094.

Where does CPU 1515SP PC2 ship from, and how fast?

CPU 1515SP PC2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC ET 200SP

Brand
Siemens
Series
SIMATIC ET 200SP
$3,990.50 On request
Get a Quote
Quote

Get a Quote

CPU 1515SP PC2

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7677-2DB42-0GB1

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart