The Siemens 6ES7677-2DB42-0GB1 is a SIMATIC ET 200SP Open Controller, CPU1515SP PC2, running the newer S7-1500 Software Controller CPU 1505SP V3x on Windows 10 IoT Enterprise LTSC 2021. Firmware V31.1 raises the program work memory to 2 Mbyte and data memory to 7.5 Mbyte, with an 8 000-element CPU-blocks budget - both larger than the V2x baseline on the same Intel Atom E3940 hardware with 8 GB RAM and 128 GB CFast.
Choose the 6ES7677-2DB42-0GB1 over the V2x-based 6ES7677-2DB42-0GB0 when the program needs the larger 8 000-element block budget or the extra 16 ET 200AL modules the V3x firmware supports (82 modules per rack versus 64). LTSC 2021 also extends the Windows support window past the LTSC 2019 image used on the -0GB0/-0GK0/-0GL0/-0GM0 variants, which matters for long-running installations planning OS updates.
Fits new machine designs that want the longest available Windows LTSC support horizon together with the larger V3x memory and block limits, rather than matching an existing V2x fleet for uniformity.
| Product type designation | CPU 1515SP PC2 |
|---|---|
| Firmware version | V31.1 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs |
| Product function: SysLog | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V20 (FW V31.1) / V18 (FW V30.0) or higher |
| Installed software: Visualization | No |
| Installed software: Control | S7-1500 Software Controller CPU 1505SP |
| via dataset | Yes |
|---|
| Mode selector switch | 1 |
|---|
| Part number | 6ES7677-2DB42-0GB1 |
|---|---|
| Type designation | CPU 1515SP PC2 |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623414094 |
| ETIM class | EC001603 |
| eCl@ss | 27242607 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 5 ms |
| Current consumption (rated value) | 1.8 A; Full processor load, incl. ET 200SP modules and using USB |
|---|---|
| Current consumption (in no-load operation), typ. | 0.5 A |
| Current consumption, max. | 2.9 A |
| I2t | 0.426 A2·s; with starting current inrush |
| Active power input, max. | 43 W; incl. ET 200SP modules and using USB |
|---|---|
| Infeed power to the backplane bus | 8.75 W |
| Power loss, typ. | 16 W |
|---|
| Processor type | Intel Atom E3940, 1.6 GHz, 4 cores |
|---|
| Type of memory | DDR3L |
|---|---|
| Main memory | 8 GB RAM |
| CFast memory card | Yes; 128 GB flash memory |
| SIMATIC memory card required | No |
| Work memory: integrated (for program) | 2 Mbyte |
| Work memory: integrated (for data) | 7.5 Mbyte |
| Work memory: integrated (for CPU function library of CPU Runtime) | 20 Mbyte |
| Load memory: integrated (on PC mass storage) | 320 Mbyte |
| Backup: with UPS | Yes; all memory areas declared retentive |
| Backup: with non-volatile memory | Yes |
| Number of elements (total) | 8 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements |
|---|---|
| DB: Number, max. | 7 999; Number range: 1 to 65535 |
| DB: Size, max. | 5 Mbyte |
| FB: Number, max. | 7 998; Number range: 1 to 65535 |
| FB: Size, max. | 1 024 kbyte |
| FC: Number, max. | 7 999; Number range: 1 to 65535 |
| FC: Size, max. | 1 024 kbyte |
| OB: Size, max. | 1 024 kbyte |
| OB: Number of free cycle OBs | 100 |
| OB: Number of time alarm OBs | 20 |
| OB: Number of delay alarm OBs | 20 |
| OB: Number of cyclic interrupt OBs | 20 |
| OB: Number of process alarm OBs | 50 |
| OB: Number of DPV1 alarm OBs | 3 |
| OB: Number of isochronous mode OBs | 1 |
| OB: Number of technology synchronous alarm OBs | 2 |
| OB: Number of startup OBs | 100 |
| OB: Number of asynchronous error OBs | 4 |
| OB: Number of synchronous error OBs | 2 |
| OB: Number of diagnostic alarm OBs | 1 |
| Nesting depth: per priority class | 24 |
| S7 counter: Number Retentivity | 2 048 |
|---|---|
| S7 counter: adjustable | Yes |
| IEC counter: Number Retentivity | Any (only limited by the main memory) |
| IEC counter: can be set | Yes |
| S7 timer: Number Retentivity | 2 048 |
| S7 timer: adjustable | Yes |
| IEC timer: Number Retentivity | Any (only limited by the main memory) |
| IEC timer: can be set | Yes |
| Retentive data area (incl. timers, counters, flags), max. | 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes |
|---|---|
| Flag: Size, max. | 16 kbyte |
| Flag: Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks: Retentivity adjustable | Yes |
| Data blocks: Retentivity preset | No |
| Local data: per priority class, max. | 64 kbyte; max. 16 KB per block |
| Number of IO modules | 8 192 |
|---|---|
| I/O address area: Inputs | 32 kbyte; All inputs are in the process image |
| I/O address area: Outputs | 32 kbyte; All outputs are in the process image |
| Subprocess images: Number of subprocess images, max. | 32 |
| Integrated power supply | Yes |
|---|---|
| Number of distributed IO systems | 20 |
| Number of DP masters: Via CM | 1 |
| Number of IO Controllers: via PC interfaces | 1 |
| Rack: Modules per rack, max. | 82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules |
| Rack: Quantity of operable ET 200SP modules, max. | 64 |
| Rack: Quantity of operable ET 200AL modules, max. | 16 |
| Rack: Number of lines, max. | 1 |
| PtP CM: Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
| Clock: Type | Hardware clock |
|---|---|
| Clock: Hardware clock (real-time) | Yes; Resolution: 1 s |
| Clock: Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Clock: Deviation per day, max. | 10 s; Typ.: 2 s |
| Clock synchronization: supported | Yes |
| Clock synchronization: to DP, master | Yes; Via CM DP module |
| Clock synchronization: on Ethernet via NTP | Yes |
| Clock synchronization: on Windows clock, device | Yes |
| Number of industrial Ethernet interfaces | 2 |
|---|---|
| Number of PROFINET interfaces | 1 |
| Number of PROFIBUS interfaces | 1; Via CM DP module |
| Number of RS 485 interfaces | 1; Via CM DP module |
| Number of USB interfaces | 4; 2x USB 2.0, 2x USB 3.0 on front side |
| Number of SD card slots | 1 |
| Video interfaces: Graphics interface | 1x DisplayPort |
| Interface type | PROFINET |
|---|---|
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Number of connections | 88 |
| Interface types: RJ 45 (Ethernet) | Yes; Via BusAdapter BA 2x RJ45 |
| Interface types: Transmission rate, max. | 100 Mbit/s |
| Interface types: Industrial Ethernet status LED | Yes |
| Interface types: Number of ports | 2 |
| Interface types: integrated switch | Yes |
| Interface types: BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC |
| Protocols: IP protocol | Yes; IPv4 |
| Protocols: PROFINET IO Controller | Yes |
| Protocols: PROFINET IO device | Yes |
| Protocols: SIMATIC communication | Yes |
| Protocols: Open IE communication | Yes; Optionally also encrypted |
| Protocols: Web server | Yes |
| Protocols: Media redundancy | Yes |
| PROFINET IO Controller Services: Isochronous mode | Yes |
| PROFINET IO Controller Services: Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| PROFINET IO Controller Services: shortest clock pulse | 500 µs |
| PROFINET IO Controller Services: IRT | Yes |
| PROFINET IO Controller Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Controller Services: PROFIenergy | Yes |
| PROFINET IO Controller Services: Prioritized startup | Yes; Max. 32 PROFINET devices |
| PROFINET IO Controller Services: Number of connectable IO Devices, max. | 128 |
| PROFINET IO Controller Services: Of which IO devices with IRT, max. | 64 |
| PROFINET IO Controller Services: of which in line, max. | 64 |
| PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| PROFINET IO Controller Services: IO Devices changing during operation (partner ports), supported | Yes |
| PROFINET IO Controller Services: Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller Services: Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET IO Controller Services: PROFINET Security Class Update time for IRT | 1 |
| PROFINET IO Controller Services: for send cycle of 500 µs | 500 µs to 8 ms |
| PROFINET IO Controller Services: for send cycle of 1 ms | 1 ms to 16 ms |
| PROFINET IO Controller Services: for send cycle of 2 ms | 2 ms to 32 ms |
| PROFINET IO Controller Services: for send cycle of 4 ms | 4 ms to 64 ms |
| PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT | Update time = set "odd" send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs |
| PROFINET IO Controller Services: for send cycle of 4 ms Address area | 4 ms to 512 ms |
| PROFINET IO Controller Services: Inputs, max. | 8 kbyte |
| PROFINET IO Controller Services: Outputs, max. | 8 kbyte |
| PROFINET IO Device Services: Isochronous mode | No |
| PROFINET IO Device Services: IRT | Yes |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Device Services: PROFIenergy | Yes; per user program |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 4 |
| PROFINET IO Device Services: activation/deactivation of I-devices | Yes; per user program |
| PROFINET IO Device Services: Asset management record | Yes; per user program |
| PROFINET IO Device Services: PROFINET Security Class | SNMP Configuration and DCP Read Only |
| Interface type | Integrated Ethernet interface |
|---|---|
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Interface types: RJ 45 (Ethernet) | Yes; Integrated |
| Interface types: Transmission rate, max. | 1 000 Mbit/s |
| Interface types: Industrial Ethernet status LED | No |
| Interface types: Number of ports | 1 |
| Interface type | PROFIBUS with CM DP |
|---|---|
| Number of connections | 44 |
| Interface types: RS 485 | Yes |
| Protocols: PROFIBUS DP master | Yes |
| Protocols: PROFIBUS DP device | Yes |
| Protocols: SIMATIC communication | Yes |
| PROFIBUS DP master: max. number of DP devices Services | 125 |
| PROFIBUS DP master: Equidistance | No |
| PROFIBUS DP master: Isochronous mode Address area | No |
| PROFIBUS DP master: Inputs, max. | 8 kbyte |
| PROFIBUS DP master: Outputs, max. | 8 kbyte |
| RS 485: Transmission rate, max. | 12 Mbit/s |
|---|
| PROFIsafe | No |
|---|---|
| Number of connections: Number of connections, max. | 88 |
| Number of connections: Number of connections reserved for ES/HMI/web | 10 |
| Number of connections: Number of S7 routing paths | 16 |
| Redundancy mode: PROFINET system redundancy (S2) | No |
| Redundancy mode: PROFINET system redundancy (R1) Media redundancy | No |
| Redundancy mode: Media redundancy | Yes; only via BusAdapter |
| Redundancy mode: MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
| Redundancy mode: MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| Redundancy mode: MRPD | Yes; Requirement: IRT |
| Redundancy mode: Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Redundancy mode: Number of stations in the ring, max. | 50 |
| SIMATIC communication: PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| SIMATIC communication: S7 routing | Yes |
| SIMATIC communication: S7 communication, as server | Yes |
| SIMATIC communication: S7 communication, as client | Yes |
| SIMATIC communication: User data per job, max. | 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: Data length, max. | 64 kbyte |
| Open IE communication: ISO-on-TCP (RFC1006) | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: UDP multicast | Yes; Max. 5 multicast circuits |
| Open IE communication: DHCP | Yes |
| Open IE communication: DNS | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: DCP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: Encryption | Yes; Optional |
| Web server: HTTP | Yes; Standard and user pages |
| Web server: HTTPS | Yes; Standard and user pages |
| web API: Number of sessions, max. | 50 |
| web API: number of simultaneous HTTP calls, max. | 4 |
| web API: HTTP request body, max. | 131 072 byte |
| OPC UA: Runtime license required | Yes; "Small" license required |
| OPC UA: OPC UA Client | Yes; Data access (read, write), method call |
| OPC UA: Application authentication | Yes |
| OPC UA: Security policies | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| OPC UA: User authentication | Yes; "anonymous" or by user name & password |
| OPC UA: Number of connections, max. | 10 |
| OPC UA: Number of nodes of the client interfaces, recommended max. | 2 000 |
| Number of elements for one call of 300 OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.: Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
| Further protocols: MODBUS | Yes; MODBUS TCP |
| Number of login stations for message functions, max. | 32 |
|---|---|
| Program alarms | Yes |
| Number of configurable program messages, max. | 10 000 |
| Number of simultaneously active program alarms | 1 000 |
| Number of program alarms | 1 000 |
| Number of alarms for system diagnostics | 200 |
| Number of alarms for motion technology objects | 160 |
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 10 engineering systems |
|---|---|
| Status block | Yes; up to 8 simultaneously |
| Single step | Yes |
| Number of breakpoints | 8 |
| Profiling | No |
| Status/control: Status/control variable | Yes |
| Status/control: Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max.: of which status variables, max. | 200; per job |
| Number of variables, max.: of which control variables, max. | 200; per job |
| Forcing: Forcing | Yes |
| Forcing: Forcing, variables | Peripheral inputs/outputs |
| Forcing: Number of variables, max. | 200 |
| Diagnostic buffer: present | Yes |
| Diagnostic buffer: Number of entries, max. | 1 000 |
| Diagnostic buffer: of which powerfail-proof | 300 |
| Traces: Number of configurable Traces | 4 |
| Traces: Memory size per trace, max. | 512 kbyte |
| Diagnostics indication LED: RUN/STOP LED | Yes |
|---|---|
| Diagnostics indication LED: ERROR LED | Yes |
| Diagnostics indication LED: MAINT LED | Yes |
| Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER |
|---|---|
| Number of available Motion Control resources for technology objects | 2 400 |
| Required Motion Control resources: per speed-controlled axis | 40 |
| Required Motion Control resources: per positioning axis | 80 |
| Required Motion Control resources: per synchronous axis | 160 |
| Required Motion Control resources: per external encoder | 80 |
| Required Motion Control resources: per output cam | 20 |
| Required Motion Control resources: per cam track | 160 |
| Required Motion Control resources: per probe | 40 |
| Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) | 30 |
| Controller: PID_Compact | Yes; Universal PID controller with integrated optimization |
| Controller: PID_3Step | Yes; PID controller with integrated optimization for valves |
| Controller: PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring: High-speed counter | Yes |
| CE mark | Yes |
|---|---|
| CSA approval | Yes |
| cULus | Yes |
| FM approval | Yes |
| RCM (formerly C-TICK) | Yes |
| Ambient temperature during operation: min. | -20 °C |
|---|---|
| Ambient temperature during operation: horizontal installation, min. | -20 °C |
| Ambient temperature during operation: vertical installation, min. | -20 °C |
| Ambient temperature during storage/transportation: min. | -40 °C |
| Ambient temperature during storage/transportation: max. | 70 °C |
| Vibrations: Operation, tested according to IEC 60068-2-6 | Yes |
| Vibrations: Transport, tested acc. to IEC 60068-2-6 | Yes |
| Shock testing: tested according to IEC 60068-2-6 | Yes |
| Shock testing: tested according to IEC 60068-2-27 | Yes |
| Shock testing: tested according to IEC 60068-2-29 | Yes |
| Shock testing: Storage/transport, tested acc. to IEC 60068-2-27 | Yes |
| pre-installed operating system | Windows 10 IoT Enterprise 2021 LTSC |
|---|
| Programming Programming language: LAD | Yes |
|---|---|
| Programming Programming language: FBD | Yes |
| Programming Programming language: STL | Yes |
| Programming Programming language: SCL | Yes |
| Programming Programming language: CFC | No |
| Programming Programming language: GRAPH | Yes |
| Know-how protection: User program protection/password protection | Yes |
| Know-how protection: Copy protection | Yes |
| Know-how protection: Block protection | Yes |
| Access protection: protection of confidential configuration data | Yes |
| Access protection: Protection level: Write protection | Yes |
| Access protection: Protection level: Read/write protection | Yes |
| Access protection: Protection level: Complete protection | Yes |
| Access protection: User administration | Yes; device-wide |
| Access protection: Number of users | 100 |
| Cycle time monitoring: lower limit | adjustable minimum cycle time |
| Cycle time monitoring: upper limit | adjustable maximum cycle time |
| Open Development interfaces: Size of ODK SO file, max. | 5.8 Mbyte |
| SD card | Optionally for additional mass storage |
|---|
| eClass | 16 27-24-26-07 |
|---|---|
| ETIM | 10 EC001603 |
| IDEA | 4 3565 |
| UNSPSC | 15 32-15-17-05 |
| Net weight | 1.028 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.528 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CPU 1515SP PC2 is 1.8 A.
The rated operational voltage of CPU 1515SP PC2 is 24 V AC.
The tariff (HS) code on file for CPU 1515SP PC2 is 85371091.
The EAN (GTIN) of CPU 1515SP PC2 is 4047623414094.
CPU 1515SP PC2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.