Rated current
1.8 A
Rated operational voltage
24 V AC
Communication
PROFINET, PROFIBUS (via CM), RS 485 (via CM), 4x USB
Display
1x DisplayPort (no integrated screen)
EAN
4047623409830
Description

About the CPU 1515SP PC2

The Siemens 6ES7677-2DB42-0GB0 is a SIMATIC ET 200SP Open Controller, CPU1515SP PC2: an Intel Atom E3940 industrial PC with 8 GB RAM and a 128 GB CFast card, preloaded with Windows 10 IoT Enterprise LTSC 2019 and the S7-1500 Software Controller CPU 1505SP V2x. It runs the PLC program on the PC hardware itself, with PROFINET, PROFIBUS via CM, and 4 USB ports for engineering and field connections.

Certifications & Standards

  • CE
  • CSA
  • cULus
  • FM
  • RCM

Selection Notes

Choose the 6ES7677-2DB42-0GB0 when the machine needs a PC-class software PLC without onboard HMI runtime: its 6 000-element CPU-blocks budget and 1 Mbyte program / 5 Mbyte data work memory match the 6ES7677-2DB42-0GB1 firmware V21.9 baseline rather than the larger V3x memory of the -0GB1 variant. If the line also needs a local screen, the -0GK0/-0GL0/-0GM0 variants add WinCC Runtime Advanced with a PowerTags license instead of running visualization on a separate panel.

Applications

Suits machine builders replacing a rack-mounted S7-1500 CPU with a single PC-form-factor controller, such as retrofits where the cabinet already has 24 V DC and PROFINET wiring but no space for a full I/O rack.

Specification

Full specification

284 values · Last verified 01 Nov 2026

General information 6

Product type designation CPU 1515SP PC2
HW functional status from FS04
Firmware version V21.9
Engineering with: STEP 7 TIA Portal configurable/integrated from version V17
Installed software: Visualization No
Installed software: Control S7-1500 Software Controller CPU 1505SP

Configuration control 1

via dataset Yes

Control elements 1

Mode selector switch 1
Show all 284 specifications ↓ Show less ↑276 more values in Identification, Supply voltage, Input current, Power, Power loss, Processor, Storage, CPU-blocks, Counters, timers and their retentivity, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Interfaces, 1. Interface, 2. Interface, 3. Interface, Interface types, Protocols, S7 message functions, Test commissioning functions, Interrupts/diagnostics/status information, Supported technology objects, Standards, approvals, certificates, Ambient conditions, Operating systems, Configuration, Version Classification, Logistics.

Identification 10

Part number 6ES7677-2DB42-0GB0
Type designation CPU 1515SP PC2
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4047623409830
ETIM class EC001603
eCl@ss 27242607

Supply voltage 5

Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering: Mains/voltage failure stored energy time 5 ms

Input current 4

Current consumption (rated value) 1.8 A; Full processor load, incl. ET 200SP modules and using USB
Current consumption (in no-load operation), typ. 0.5 A
Current consumption, max. 2.9 A
I2t 0.426 A2·s; with starting current inrush

Power 2

Active power input, max. 43 W; incl. ET 200SP modules and using USB
Infeed power to the backplane bus 8.75 W

Power loss 1

Power loss, typ. 15 W; without ET 200SP modules and without using USB

Processor 1

Processor type Intel Atom E3940, 1.6 GHz, 4 cores

Storage 10

Type of memory DDR3L
Main memory 8 GB RAM
CFast memory card Yes; 128 GB flash memory
SIMATIC memory card required No
Work memory: integrated (for program) 1 Mbyte
Work memory: integrated (for data) 5 Mbyte
Work memory: integrated (for CPU function library of CPU Runtime) 20 Mbyte
Load memory: integrated (on PC mass storage) 320 Mbyte
Backup: with UPS Yes; all memory areas declared retentive
Backup: with non-volatile memory Yes

CPU-blocks 21

Number of elements (total) 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements
DB: Number, max. 5 999; Number range: 1 to 65535
DB: Size, max. 5 Mbyte
FB: Number, max. 5 998; Number range: 1 to 65535
FB: Size, max. 1 024 kbyte
FC: Number, max. 5 999; Number range: 1 to 65535
FC: Size, max. 1 024 kbyte
OB: Size, max. 1 024 kbyte
OB: Number of free cycle OBs 100
OB: Number of time alarm OBs 20
OB: Number of delay alarm OBs 20
OB: Number of cyclic interrupt OBs 20
OB: Number of process alarm OBs 50
OB: Number of DPV1 alarm OBs 3
OB: Number of isochronous mode OBs 1
OB: Number of technology synchronous alarm OBs 2
OB: Number of startup OBs 100
OB: Number of asynchronous error OBs 4
OB: Number of synchronous error OBs 2
OB: Number of diagnostic alarm OBs 1
Nesting depth: per priority class 24

Counters, timers and their retentivity 8

S7 counter: Number Retentivity 2 048
S7 counter: adjustable Yes
IEC counter: Number Retentivity Any (only limited by the main memory)
IEC counter: adjustable Yes
S7 timer: Number Retentivity 2 048
S7 timer: adjustable Yes
IEC timer: Number Retentivity Any (only limited by the main memory)
IEC timer: adjustable Yes

Data areas and their retentivity 6

Retentive data area (incl. timers, counters, flags), max. 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes
Flag: Size, max. 16 kbyte
Flag: Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks: Retentivity adjustable Yes
Data blocks: Retentivity preset No
Local data: per priority class, max. 64 kbyte; max. 16 KB per block

Address area 4

Number of IO modules 8 192
I/O address area: Inputs 32 kbyte; All inputs are in the process image
I/O address area: Outputs 32 kbyte; All outputs are in the process image
Subprocess images: Number of subprocess images, max. 32

Hardware configuration 9

Integrated power supply Yes
Number of distributed IO systems 20
Number of DP masters: Via CM 1
Number of IO Controllers: via PC interfaces 1
Rack: Modules per rack, max. 64; CPU 1515SP PC + 64 modules + server module
Rack: Quantity of operable ET 200SP modules, max. 64
Rack: Quantity of operable ET 200AL modules, max. 16
Rack: Number of lines, max. 1
PtP CM: Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots

Time of day 8

Clock: Type Hardware clock
Clock: Hardware clock (real-time) Yes; Resolution: 1 s
Clock: Backup time 6 wk; At 40 °C ambient temperature, typically
Clock: Deviation per day, max. 10 s; Typ.: 2 s
Clock synchronization: supported Yes
Clock synchronization: to DP, master Yes
Clock synchronization: on Ethernet via NTP Yes
Clock synchronization: on Windows clock, device Yes

Interfaces 7

Number of industrial Ethernet interfaces 2
Number of PROFINET interfaces 1
Number of PROFIBUS interfaces 1
Number of RS 485 interfaces 1; Via CM DP module
Number of USB interfaces 4; 2x USB 2.0, 2x USB 3.0 on front side
Number of SD card slots 1
Video interfaces: Graphics interface 1x DisplayPort

1. Interface 47

Interface type PROFINET
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Number of connections 88
Interface types: RJ 45 (Ethernet) Yes; Via BusAdapter BA 2x RJ45
Interface types: Transmission rate, max. 100 Mbit/s
Interface types: Industrial Ethernet status LED Yes
Interface types: Number of ports 2
Interface types: integrated switch Yes
Interface types: BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC,
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO Device Yes
Protocols: SIMATIC communication Yes
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
PROFINET IO Controller Services: Isochronous mode Yes
PROFINET IO Controller Services: shortest clock pulse 500 µs
PROFINET IO Controller Services: IRT Yes
PROFINET IO Controller Services: Dynamic Frame Packing (DFP) No
PROFINET IO Controller Services: PROFIenergy Yes
PROFINET IO Controller Services: Prioritized startup Yes; max. 32 PROFINET devices; if you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE)
PROFINET IO Controller Services: Number of connectable IO Devices, max. 128
PROFINET IO Controller Services: Of which IO devices with IRT, max. 64
PROFINET IO Controller Services: of which in line, max. 64
PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. 8
PROFINET IO Controller Services: IO Devices changing during operation (partner ports), supported Yes
PROFINET IO Controller Services: Number of IO Devices per tool, max. 8
PROFINET IO Controller Services: Updating times Update time for IRT The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
PROFINET IO Controller Services: for send cycle of 500 µs 500 µs to 8 ms
PROFINET IO Controller Services: for send cycle of 1 ms 1 ms to 16 ms
PROFINET IO Controller Services: for send cycle of 2 ms 2 ms to 32 ms
PROFINET IO Controller Services: for send cycle of 4 ms 4 ms to 64 ms
PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT Update time = set "odd" send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs
PROFINET IO Controller Services: for send cycle of 4 ms Address area 4 ms to 512 ms
PROFINET IO Controller Services: Inputs, max. 8 kbyte
PROFINET IO Controller Services: Outputs, max. 8 kbyte
PROFINET IO Device Services: Isochronous mode No
PROFINET IO Device Services: shortest clock pulse 500 µs
PROFINET IO Device Services: IRT Yes
PROFINET IO Device Services: Dynamic Frame Packing (DFP) No
PROFINET IO Device Services: PROFIenergy Yes
PROFINET IO Device Services: Prioritized startup Yes
PROFINET IO Device Services: Shared device Yes
PROFINET IO Device Services: Number of IO Controllers with shared device, max. 4
PROFINET IO Device Services: Asset management record Yes

2. Interface 8

Interface type Integrated Ethernet interface
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface types: RJ 45 (Ethernet) Yes; Integrated
Interface types: Transmission rate, max. 1 000 Mbit/s
Interface types: Industrial Ethernet status LED No
Interface types: Number of ports 1

3. Interface 11

Interface type PROFIBUS with CM DP
Number of connections 44
Interface types: RS 485 Yes
Protocols: PROFIBUS DP master Yes
Protocols: PROFIBUS DP device Yes
Protocols: SIMATIC communication Yes
PROFIBUS DP master: max. number of DP devices Services 125
PROFIBUS DP master: Equidistance No
PROFIBUS DP master: Isochronous mode Address area No
PROFIBUS DP master: Inputs, max. 8 kbyte
PROFIBUS DP master: Outputs, max. 8 kbyte

Interface types 1

RS 485: Transmission rate, max. 12 Mbit/s

Protocols 32

PROFIsafe No
Number of connections: Number of connections, max. 88
Number of connections: Number of connections reserved for ES/HMI/web 10
Number of connections: Number of S7 routing paths 16
Redundancy mode: PROFINET system redundancy (S2) No
Redundancy mode: PROFINET system redundancy (R1) Media redundancy No
Redundancy mode: MRP Yes
Redundancy mode: MRP interconnection, supported Yes
Redundancy mode: MRPD Yes
Redundancy mode: Switchover time on line break, typ. 200 ms
Redundancy mode: Number of stations in the ring, max. 50
SIMATIC communication: PG/OP communication Yes
SIMATIC communication: S7 routing Yes
SIMATIC communication: S7 communication, as server Yes
SIMATIC communication: S7 communication, as client Yes
SIMATIC communication: User data per job, max. 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes
Open IE communication: TCP/IP Yes
Open IE communication: Data length, max. 64 kbyte
Open IE communication: ISO-on-TCP (RFC1006) Yes
Open IE communication: UDP Yes
Open IE communication: SNMP Yes
Open IE communication: DCP Yes
Open IE communication: LLDP Yes
Web server: HTTP Yes; Via Windows and PROFINET interface
Web server: HTTPS Yes; Via Windows and PROFINET interface
OPC UA: Runtime license required Yes; "Small" license required
OPC UA: OPC UA Client Yes; From SW CPU 1505SP V2.6
OPC UA: OPC UA Server Yes; Data access (read, write, subscribe), runtime license required
OPC UA: Application authentication Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
OPC UA: Security policies Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
OPC UA: User authentication Yes; "anonymous" or by user name & password
Further protocols: MODBUS Yes; MODBUS TCP

S7 message functions 7

Number of login stations for message functions, max. 32
Program alarms Yes
Number of configurable program messages, max. 10 000
Number of simultaneously active program alarms 1 000
Number of program alarms 1 000
Number of alarms for system diagnostics 200
Number of alarms for motion technology objects 160

Test commissioning functions 16

Joint commission (Team Engineering) Yes; Parallel online access possible for up to 8 engineering systems
Status block Yes; up to 8 simultaneously
Single step No
Number of breakpoints 8
Status/control: Status/control variable Yes
Status/control: Variables Inputs, outputs, memory bits, DB, times, counters
Number of variables, max.: of which status variables, max. 200
Number of variables, max.: of which control variables, max. 200
Forcing: Forcing Yes
Forcing: Forcing, variables Inputs, outputs
Forcing: Number of variables, max. 200
Diagnostic buffer: present Yes
Diagnostic buffer: Number of entries, max. 1 000
Diagnostic buffer: of which powerfail-proof 300
Traces: Number of configurable Traces 4
Traces: Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information 3

Diagnostics indication LED: RUN/STOP LED Yes
Diagnostics indication LED: ERROR LED Yes
Diagnostics indication LED: MAINT LED Yes

Supported technology objects 14

Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects 2 400
Required Motion Control resources: per speed-controlled axis 40; per axis
Required Motion Control resources: per positioning axis 80; per axis
Required Motion Control resources: per synchronous axis 160; per axis
Required Motion Control resources: per external encoder 80; per external encoder
Required Motion Control resources: per output cam 20; per cam
Required Motion Control resources: per cam track 160; per cam track
Required Motion Control resources: per probe 40; per probe
Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) 15
Controller: PID_Compact Yes; Universal PID controller with integrated optimization
Controller: PID_3Step Yes; PID controller with integrated optimization for valves
Controller: PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring: High-speed counter Yes

Standards, approvals, certificates 10

CE mark Yes
CSA approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
Ecological footprint: environmental product declaration Global warming potential Yes
Ecological footprint: global warming potential, (total) [CO2 eq] 432 kg
Ecological footprint: global warming potential, (during production) [CO2 eq] 73.8 kg
Ecological footprint: global warming potential, (during operation) [CO2 eq] 365 kg
Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] -6.71 kg

Ambient conditions 11

Ambient temperature during operation: min. -20 °C
Ambient temperature during operation: horizontal installation, min. -20 °C
Ambient temperature during operation: vertical installation, min. -20 °C
Ambient temperature during storage/transportation: min. -40 °C
Ambient temperature during storage/transportation: max. 70 °C
Vibrations: Operation, tested according to IEC 60068-2-6 Yes
Vibrations: Transport, tested acc. to IEC 60068-2-6 Yes
Shock testing: tested according to IEC 60068-2-6 Yes
Shock testing: tested according to IEC 60068-2-27 Yes
Shock testing: tested according to IEC 60068-2-29 Yes
Shock testing: Storage/transport, tested acc. to IEC 60068-2-27 Yes

Operating systems 1

pre-installed operating system Windows 10 IoT Enterprise 2019 LTSC, 64 bit, MUI

Configuration 9

Programming Programming language: LAD Yes
Programming Programming language: FBD Yes
Programming Programming language: STL Yes
Programming Programming language: SCL Yes
Programming Programming language: CFC No
Programming Programming language: GRAPH Yes
Know-how protection: User program protection/password protection Yes
Know-how protection: Copy protection Yes
Know-how protection: Block protection Yes

Version Classification 4

eClass 16 27-24-26-07
ETIM 10 EC001603
IDEA 4 3565
UNSPSC 15 32-15-17-05

Logistics 6

Net weight 1.031 kg
Country of origin DE
Shipping weight 1.531 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7677-2DB42-0GB0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE mark
  • CSA approval
  • cULus
  • FM approval
  • RCM (formerly C-TICK)
Quick answers

Questions about the CPU 1515SP PC2

What is the rated current of CPU 1515SP PC2?

The rated current of CPU 1515SP PC2 is 1.8 A.

Which supply voltage is CPU 1515SP PC2 rated for?

The rated operational voltage of CPU 1515SP PC2 is 24 V AC.

What is the HS code of CPU 1515SP PC2 for customs?

The tariff (HS) code on file for CPU 1515SP PC2 is 85371091.

What is the EAN of CPU 1515SP PC2?

The EAN (GTIN) of CPU 1515SP PC2 is 4047623409830.

Where does CPU 1515SP PC2 ship from, and how fast?

CPU 1515SP PC2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC ET 200SP

Brand
Siemens
Series
SIMATIC ET 200SP
$4,388.40 On request
Get a Quote
Quote

Get a Quote

CPU 1515SP PC2

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7677-2DB42-0GB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart