Part number
6ES7552-1AA00-0AB0
Model no
TM Timer DIDQ 16x24V
$703.80 On request Dispatch — · From TürkiyeAsk us for an alternative
Discontinued by the manufacturer

Siemens has discontinued 6ES7552-1AA00-0AB0

We sell remaining stock while it lasts.

No replacement announced yet. Tell us the application and we will propose an alternative.

SIMATIC S7-1500

Siemens 6ES7552-1AA00-0AB0 SIMATIC S7-1500 TM Timer DIDQ 16x24V Time-Stamped I/O Module

SIMATIC S7-1500 TM Timer DIDQ 16x24V, up to 8 DI/16 DQ with time stamp, PWM, oversampling.

Rated current
0.5 A
Rated operational voltage
24 V AC
EAN
4047623403791
Description

About the TM Timer DIDQ 16x24V

The Siemens 6ES7552-1AA00-0AB0 is a SIMATIC S7-1500 TM Timer DIDQ 16x24V module providing up to 8 time-stamped digital inputs and 16 digital outputs, up to 16 of which carry a time stamp, at 24 V DC, with integrated counting, PWM, and oversampling functions. It runs on two separate 24 V DC load voltages and mounts directly on the S7-1500 rail.

Selection Notes

Up to 16 of the digital outputs and up to 8 of the digital inputs can carry a hardware time stamp, so event sequencing on fast machine cycles does not depend on the CPU scan cycle catching the edge. PWM output and oversampling on the DQ side let a single channel generate a pulse train or sample faster than the base cycle time, useful where a standard fixed-sample DI/DQ module would miss short pulses. Four integrated counters, up to 200 kHz with quadruple evaluation on 24 V incremental encoders, cover speed or position feedback from simple 2-wire proximity sensors without a dedicated high-speed counting module. Two separate 24 V load-voltage groups, 1L+ for inputs and 2L+ for the encoder and output side, let a fault on one circuit be cleared without dropping the other.

Applications

Event logging and fast sequencing where the timing of a digital signal edge matters, such as packaging machines correlating a sensor trip with an actuator response, or PWM-driven valve control combined with time-stamped feedback for diagnostics.

Specification

Full specification

128 values · Last verified 01 Nov 2026

General information 4

Product type designation TM Timer DIDQ 16x24V
Product function: I&M data Yes; I&M 0
Product function: Isochronous mode Yes
Engineering with: STEP 7 TIA Portal configurable/integrated from version V13 Update 3

Installation type/mounting 1

Rail mounting Yes; S7-1500 mounting rail

Supply voltage 8

Load voltage 1L+: Rated value (DC) 24 V
Load voltage 1L+: permissible range, lower limit (DC) 19.2 V
Load voltage 1L+: permissible range, upper limit (DC) 28.8 V
Load voltage 1L+: Reverse polarity protection Yes; against destruction
Load voltage 2L+: Rated value (DC) 24 V
Load voltage 2L+: permissible range, lower limit (DC) 19.2 V
Load voltage 2L+: permissible range, upper limit (DC) 28.8 V
Load voltage 2L+: Reverse polarity protection Yes; against destruction
Show all 128 specifications ↓ Show less ↑115 more values in Identification, Input current, Encoder supply, Power, Power loss, Address area, Digital inputs, Digital outputs, Encoder, Isochronous mode, Interrupts/diagnostics/status information, Integrated Functions, Potential separation, Isolation, Ambient conditions, Decentralized operation, Dimensions, Weights, Logistics.

Identification 8

Part number 6ES7552-1AA00-0AB0
Type designation TM Timer DIDQ 16x24V
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Discontinued by the manufacturer
EAN 4047623403791

Input current 2

from load voltage 1L+ (without load), max. 40 mA; without load
from load voltage 2L+ (without load), max. 30 mA; without load

Encoder supply 4

Number of outputs 8; max. depending on parameterization
24 V encoder supply: 24 V Yes; L+ (-0.8 V)
24 V encoder supply: Short-circuit protection Yes
24 V encoder supply: Output current, max. 1.2 A; Total current of all encoders / channels, max. 0.5 A per output

Power 1

Power consumption from the backplane bus 1.3 W

Power loss 1

Power loss, typ. 5 W

Address area 2

Address space per module: Inputs 44 byte
Address space per module: Outputs 74 byte

Digital inputs 20

Number of digital inputs 8; max. depending on parameterization
Digital inputs, parameterizable Yes
Input characteristic curve in accordance with IEC 61131, type 3 Yes
Digital input functions, parameterizable: Digital input with time stamp Yes
Digital input functions, parameterizable: Number, max. 8
Digital input functions, parameterizable: Counter Yes
Digital input functions, parameterizable: Counter for incremental encoder Yes
Digital input functions, parameterizable: Digital input with oversampling Yes
Digital input functions, parameterizable: HW enable for digital input Yes
Input voltage: Type of input voltage DC
Input voltage: Rated value (DC) 24 V
Input voltage: for signal "0" -5 ... +5 V
Input voltage: for signal "1" +11 to +30V
Input voltage: permissible voltage at input, min. -30 V; -5 V continuous, -30 V brief reverse polarity protection
Input voltage: permissible voltage at input, max. 30 V
Input current: for signal "1", typ. 2.5 mA
Input delay (for rated value of input voltage): Minimum pulse width for program reactions for standard inputs 3 µs; for parameterization "none"
Input delay (for rated value of input voltage): parameterizable Yes; none / 0.05 / 0.1 / 0.4 / 0.8 ms
Cable length: shielded, max. 1 000 m; Depending on sensor, cable quality and rate of change
Cable length: unshielded, max. 600 m; Depending on sensor, cable quality and rate of change

Digital outputs 32

Type of digital output Transistor
Number of digital outputs 16; max. depending on parameterization
in groups of 8
Current-sinking Yes; With High Speed output
Current-sourcing Yes
Digital outputs, parameterizable Yes
Short-circuit protection Yes; electronic/thermal
Response threshold, typ. 1.7 A with Standard output, 0.5 A with High Speed output
Limitation of inductive shutdown voltage to -0.8 V
Controlling a digital input Yes
Digital output functions, parameterizable: Digital output with time stamp Yes
Digital output functions, parameterizable: Number, max. 16
Digital output functions, parameterizable: PWM output Yes
Switching capacity of the outputs: with resistive load, max. 0.5 A; 0.1 A with High Speed output
Switching capacity of the outputs: on lamp load, max. 5 W; 1 W with High Speed output
Load resistance range: lower limit 48 Ω; 240 ohm with High Speed output
Load resistance range: upper limit 12 kΩ
Output voltage: Type of output voltage DC
Output voltage: for signal "0", max. 1 V; With High Speed output
Output voltage: for signal "1", min. 23.2 V; L+ (-0.8 V)
Output current: for signal "1" rated value 0.5 A; 0.1 A with High Speed output, observe derating
Output current: for signal "1" permissible range, max. 0.6 A; 0.12 A with High Speed output, observe derating
Output current: for signal "1" minimum load current 2 mA
Output current: for signal "0" residual current, max. 0.5 mA
Output delay with resistive load: "0" to "1", max. 1 µs; With High Speed output, 5 µs with Standard output
Output delay with resistive load: "1" to "0", max. 1 µs; With High Speed output, 6 µs with Standard output
Switching frequency: with resistive load, max. 10 kHz
Switching frequency: on lamp load, max. 10 Hz
Total current of the outputs: Current per group, max. 4 A
Total current of the outputs: Current per module, max. 8 A; Observe derating
Cable length: shielded, max. 1 000 m; depending on load and cable quality
Cable length: unshielded, max. 600 m; depending on load and cable quality

Encoder 11

Connectable encoders: Incremental encoder (asymmetrical) Yes
Connectable encoders: 24 V initiator Yes
Connectable encoders: 2-wire sensor Yes
Connectable encoders: permissible quiescent current (2-wire sensor), max. 1.5 mA
Encoder signals, incremental encoder (asymmetrical): Input voltage 24 V
Encoder signals, incremental encoder (asymmetrical): Input frequency, max. 50 kHz
Encoder signals, incremental encoder (asymmetrical): Counting frequency, max. 200 kHz; with quadruple evaluation
Encoder signals, incremental encoder (asymmetrical): Cable length, shielded, max. 600 m; Depending on input frequency, encoder and cable quality; max. 200 m at 50 kHz
Encoder signals, incremental encoder (asymmetrical): Incremental encoder with A/B tracks, 90° phase offset Yes
Encoder signals, incremental encoder (asymmetrical): pulse encoder Yes
Interface types: Input characteristic curve in accordance with IEC 61131, type 3 Yes

Isochronous mode 2

Bus cycle time (TDP), min. 250 µs
Jitter, max. 1 µs

Interrupts/diagnostics/status information 11

Diagnostics function Yes
Substitute values connectable Yes
Alarms: Diagnostic alarm Yes
Diagnoses: Monitoring the supply voltage Yes
Diagnoses: Short-circuit Yes
Diagnostics indication LED: RUN LED Yes; green LED
Diagnostics indication LED: ERROR LED Yes; red LED
Diagnostics indication LED: MAINT LED Yes; Yellow LED
Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) Yes; green LED
Diagnostics indication LED: Channel status display Yes; green LED
Diagnostics indication LED: for channel diagnostics Yes; red LED

Integrated Functions 5

Counter Yes
Number of counters 4
Counting frequency, max. 200 kHz; with quadruple evaluation
Counting functions: Continuous counting Yes
Position detection: Incremental acquisition Yes

Potential separation 1

Potential separation channels: between the channels and backplane bus Yes

Isolation 1

Isolation tested with 707 V DC (type test)

Ambient conditions 3

Ambient temperature during operation: horizontal installation, min. 0 °C
Ambient temperature during operation: vertical installation, min. 0 °C
Altitude during operation relating to sea level: Installation altitude above sea level, max. 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200MP system manual

Decentralized operation 1

to SIMATIC S7-1500 Yes

Dimensions 3

Width 35 mm
Height 147 mm
Depth 129 mm

Weights 1

Weight, approx. 320 g

Logistics 6

Net weight 0.436 kg
Country of origin DE
Shipping weight 0.936 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7552-1AA00-0AB0

No documents are on file for this part yet.

Ask us for the datasheet
Quick answers

Questions about the TM Timer DIDQ 16x24V

What is the rated current of TM Timer DIDQ 16x24V?

The rated current of TM Timer DIDQ 16x24V is 0.5 A.

Which supply voltage is TM Timer DIDQ 16x24V rated for?

The rated operational voltage of TM Timer DIDQ 16x24V is 24 V AC.

What is the HS code of TM Timer DIDQ 16x24V for customs?

The tariff (HS) code on file for TM Timer DIDQ 16x24V is 85389091.

What is the EAN of TM Timer DIDQ 16x24V?

The EAN (GTIN) of TM Timer DIDQ 16x24V is 4047623403791.

Where does TM Timer DIDQ 16x24V ship from, and how fast?

TM Timer DIDQ 16x24V ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC S7-1500

Brand
Siemens
Series
SIMATIC S7-1500
$703.80 On request
Ask us for an alternative
Quote

Get a Quote

TM Timer DIDQ 16x24V

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7552-1AA00-0AB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart