How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7541-1AD00-0AB0 is a SIMATIC S7-1500 CM PtP RS232 HF point-to-point communication module for RS232 serial connections up to 115.2 kbit/s through a 9-pin D-sub connector, supporting Freeport, 3964(R), USS, and Modbus RTU master or device operation. It draws 50 mA from the backplane bus and mounts directly on the S7-1500 rail.
The HF designation raises RS232 throughput to 115.2 kbit/s and adds Modbus RTU master or device operation with an 8 kbyte telegram buffer, well beyond a base RS232 PtP module's lower baud rate and smaller buffer. Modbus RTU master mode on this module addresses a single device only, 1 to 247 with extended addressing to 65535, so it suits a dedicated point-to-point Modbus link rather than a multidrop network; multidrop or long-distance wiring needs an RS422/RS485 interface module instead. The 15 m RS232 cable limit keeps this module tied to devices mounted close to the control cabinet.
Point-to-point RS232 links at 115.2 kbit/s to a single nearby device, such as a Modbus RTU-capable drive, barcode scanner, or operator terminal within 15 m of the S7-1500 station, using Freeport or 3964(R) framing where Modbus is not required.
| Product type designation | CM PtP RS 232 HF |
|---|---|
| Product function: I&M data | Yes; I&M 0 |
| Product function: Fast startup | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V12 / V12 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP2 with GSD file |
| Engineering with: PROFIBUS from GSD version/GSD revision | -/- |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Rail mounting | Yes; S7-1500 mounting rail |
|---|
| Current consumption (rated value) | 50 mA; From the backplane bus |
|---|
| Part number | 6ES7541-1AD00-0AB0 |
|---|---|
| Type designation | CM PtP RS 232 HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4025515079910 |
| Power consumption from the backplane bus | 0.75 W |
|---|
| Power loss, typ. | 0.6 W |
|---|
| Address space per module: Inputs | 8 byte |
|---|
| RS 232: Transmission rate, max. | 115.2 kbit/s |
|---|---|
| RS 232: Cable length, max. | 15 m |
| RS 232: RS 232 auxiliary signals | RTS, CTS, DTR, DSR, RI, DCD |
| Integrated protocols Freeport: Telegram length, max. | 4 kbyte |
|---|---|
| Integrated protocols Freeport: Bits per character | 7 or 8 |
| Integrated protocols Freeport: Number of stop bits | 1 or 2 bit |
| Integrated protocols Freeport: Parity 3964 (R) | None, even, odd, always 1, always 0, any |
| Integrated protocols Freeport: Parity Modbus RTU master | None, even, odd, always 1, always 0, any |
| Integrated protocols Freeport: Address area | 1 to 247, extended 1 to 65535 |
| Integrated protocols Freeport: max. number of devices Modbus RTU device | 1 |
| Telegram buffer: Buffer memory for telegrams | 8 kbyte |
| Telegram buffer: Number of telegrams which can be buffered | 255 |
| Diagnostics function | Yes |
|---|---|
| Alarms: Diagnostic alarm | Yes |
| Alarms: Hardware interrupt | No |
| Diagnoses: Wire break | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Receive RxD | Yes; Yellow LED |
| Diagnostics indication LED: Transmit TxD | Yes; Yellow LED |
| between backplane bus and interface | Yes |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200MP system manual |
| to SIMATIC S7-300 | Yes |
|---|---|
| to SIMATIC S7-400 | Yes |
| to SIMATIC S7-1500 | Yes |
| to standard PROFINET controller | Yes |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 127 mm |
| Weight, approx. | 0.22 kg |
|---|
| Net weight | 0.259 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.759 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for CM PtP RS 232 HF is 85176200.
The EAN (GTIN) of CM PtP RS 232 HF is 4025515079910.
CM PtP RS 232 HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.