Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens SIMATIC S7-1500 6ES7534-7QE00-0AB0 (AI 4xU/I/RTD/TC/AQ 2xU/I ST) is a universal analog module combining 4 analog inputs configurable for voltage, current, resistance/RTD, or thermocouple measurement with 2 analog outputs for voltage or current, at 16-bit resolution and 0.3% accuracy. It supports reparameterization and calibration in RUN (CiR) and mounts in a 35 mm S7-1500 backplane slot.
ST in the designation marks the standard-accuracy variant of this universal module - it accepts voltage, current, RTD/resistance, and thermocouple inputs on the same 4 channels, configured per channel rather than simultaneously in all modes, so one module replaces separate dedicated AI modules when a machine mixes sensor types across a small number of measurement points. Reparameterization and calibration are possible in RUN (CiR), which matters for machines that cannot be stopped to add or recalibrate a sensor channel. The 2 integrated analog outputs mean small closed-loop control, such as a valve positioner, does not need a separate AQ module alongside this one.
Used for mixed-sensor process measurement - temperature via RTD/TC, pressure or level via 4-20 mA, and position feedback via 0-10 V - combined with 2 analog control outputs on process skids, utilities, and machine sections where sensor types vary point to point.
| Product type designation | AI 4xU/I/RTD/TC /AQ 2xU/I ST |
|---|---|
| HW functional status | from FS01 |
| Firmware version | V1.0.0 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: Prioritized startup | No |
| Product function: Measuring range scalable | No |
| Product function: Scalable measured values | No |
| Product function: Adjustment of measuring range | No |
| Product function: Output range scalable | No |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V13 / V13.0.2 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: Oversampling | No |
| Operating mode: MSI | Yes |
| Operating mode: MSO | Yes |
| Reparameterization possible in RUN | Yes |
|---|---|
| Calibration possible in RUN | Yes |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Part number | 6ES7534-7QE00-0AB0 |
|---|---|
| Type designation | AI 4xU/I/RTD/TC /AQ 2xU/I ST |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623403326 |
| ETIM class | EC001420 |
| eCl@ss | 27242201 |
| Current consumption, max. | 200 mA |
|---|
| 24 V encoder supply: Short-circuit protection | Yes |
|---|---|
| 24 V encoder supply: Output current, max. | 20 mA; Max. 47 mA per channel for a duration < 10 s |
| Power consumption from the backplane bus | 0.7 W |
|---|
| Power loss, typ. | 3.3 W |
|---|
| Number of analog inputs | 4 |
|---|---|
| For current measurement | 4 |
| For voltage measurement | 4 |
| For resistance/resistance thermometer measurement | 2 |
| For thermocouple measurement | 4 |
| permissible input voltage for voltage input (destruction limit), max. | 28.8 V |
| permissible input current for current input (destruction limit), max. | 40 mA |
| Constant measurement current for resistance-type transmitter, | 150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, |
| typ. | Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA |
| Technical unit for temperature measurement adjustable | Yes; °C/°F/K |
| Analog input with oversampling | No |
| Standardization of measured values | No |
| Input ranges (rated values), voltages: 0 to +5 V | No |
| Input ranges (rated values), voltages: 0 to +10 V | No |
| Input ranges (rated values), voltages: 1 V to 5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (1 V to 5 V) | 100 kΩ |
| Input ranges (rated values), voltages: -1 V to +1 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-1 V to +1 V) | 10 MΩ |
| Input ranges (rated values), voltages: -10 V to +10 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-10 V to +10 V) | 100 kΩ |
| Input ranges (rated values), voltages: -2.5 V to +2.5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-2.5 V to +2.5 V) | 10 MΩ |
| Input ranges (rated values), voltages: -25 mV to +25 mV | No |
| Input ranges (rated values), voltages: -250 mV to +250 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-250 mV to +250 mV) | 10 MΩ |
| Input ranges (rated values), voltages: -5 V to +5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-5 V to +5 V) | 100 kΩ |
| Input ranges (rated values), voltages: -50 mV to +50 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-50 mV to +50 mV) | 10 MΩ |
| Input ranges (rated values), voltages: -500 mV to +500 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-500 mV to +500 mV) | 10 MΩ |
| Input ranges (rated values), voltages: -80 mV to +80 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-80 mV to +80 mV) | 10 MΩ |
| Input ranges (rated values), currents: 0 to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (0 to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Input ranges (rated values), currents: -20 mA to +20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (-20 mA to +20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Input ranges (rated values), currents: 4 mA to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (4 mA to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Input ranges (rated values), thermocouples: Type B | Yes |
| Input ranges (rated values), thermocouples: Input resistance (Type B) | 10 MΩ |
| Input ranges (rated values), thermocouples: Type C | No |
| Input ranges (rated values), thermocouples: Type E | Yes |
| Input ranges (rated values), thermocouples: Type J | Yes |
| Input ranges (rated values), thermocouples: Type K | Yes |
| Input ranges (rated values), thermocouples: Type L | No |
| Input ranges (rated values), thermocouples: Type N | Yes |
| Input ranges (rated values), thermocouples: Type R | Yes |
| Input ranges (rated values), thermocouples: Type S | Yes |
| Input ranges (rated values), thermocouples: Type T | Yes |
| Input ranges (rated values), thermocouples: Type U | No |
| Input ranges (rated values), thermocouples: Type TXK/TXK(L) to GOST | No |
| Input ranges (rated values), resistance thermometer: Cu 10 | No |
| Input ranges (rated values), resistance thermometer: Cu 10 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Cu 50 | No |
| Input ranges (rated values), resistance thermometer: Cu 50 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Cu 100 | No |
| Input ranges (rated values), resistance thermometer: Cu 100 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 10 | No |
| Input ranges (rated values), resistance thermometer: Ni 10 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 100 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Input resistance (Ni 100) | 10 MΩ |
| Input ranges (rated values), resistance thermometer: Ni 100 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 1000 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Ni 1000 according to GOST | No |
| Input ranges (rated values), resistance thermometer: LG-Ni 1000 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Ni 120 | No |
| Input ranges (rated values), resistance thermometer: Ni 120 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 200 | No |
| Input ranges (rated values), resistance thermometer: Ni 200 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 500 | No |
| Input ranges (rated values), resistance thermometer: Ni 500 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 10 | No |
| Input ranges (rated values), resistance thermometer: Pt 10 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 50 | No |
| Input ranges (rated values), resistance thermometer: Pt 50 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 100 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Pt 100 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 1000 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Pt 1000 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 200 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Pt 200 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 500 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer: Pt 500 according to GOST | No |
| Input ranges (rated values), resistors: 0 to 150 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 150 ohms) | 10 MΩ |
| Input ranges (rated values), resistors: 0 to 300 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 300 ohms) | 10 MΩ |
| Input ranges (rated values), resistors: 0 to 600 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 600 ohms) | 10 MΩ |
| Input ranges (rated values), resistors: 0 to 3000 ohms | No |
| Input ranges (rated values), resistors: 0 to 6000 ohms | Yes |
| Input ranges (rated values), resistors: PTC | Yes |
| Input ranges (rated values), resistors: Input resistance (PTC) | 10 MΩ |
| Thermocouple (TC) Temperature compensation: Parameterizable | Yes |
| Thermocouple (TC) Temperature compensation: internal temperature compensation | Yes |
| Thermocouple (TC) Temperature compensation: external temperature compensation via RTD | Yes |
| Thermocouple (TC) Temperature compensation: Compensation for 0 °C reference point temperature | Yes; fixed value can be set |
| Thermocouple (TC) Temperature compensation: Reference channel of the module | No |
| Cable length: shielded, max. | 800 m; for U/I, 200 m for R/RTD, 50 m for TC |
| Number of analog outputs | 2 |
|---|---|
| Voltage output, short-circuit protection | Yes |
| Voltage output, short-circuit current, max. | 24 mA |
| Current output, no-load voltage, max. | 22 V |
| Cycle time (all channels), min. | 3.2 ms; ±0.5 ms, regardless of the number of activated channels |
| Output ranges, voltage: 0 to 10 V | Yes |
| Output ranges, voltage: 1 V to 5 V | Yes |
| Output ranges, voltage: -5 V to +5 V | No |
| Output ranges, voltage: -10 V to +10 V | Yes |
| Output ranges, current: 0 to 20 mA | Yes |
| Output ranges, current: -20 mA to +20 mA | Yes |
| Output ranges, current: 4 mA to 20 mA | Yes |
| Connection of actuators: for voltage output two-wire connection | Yes |
| Connection of actuators: for voltage output four-wire connection | Yes |
| Connection of actuators: for current output two-wire connection | Yes |
| Load impedance (in rated range of output): with voltage outputs, min. | 1 kΩ; 0.5 kOhm at 1 to 5 V |
| Load impedance (in rated range of output): with current outputs, max. | 750 Ω |
| Cable length: shielded, max. | 800 m; for current, 200 m for voltage |
| Measurement principle | integrating |
|---|---|
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit |
| Integration and conversion time/resolution per channel: Integration time, parameterizable | Yes |
| Integration and conversion time/resolution per channel: Basic conversion time, including integration time (ms) | 9 / 23 / 27 / 107 ms |
| Integration and conversion time/resolution per channel: additional conversion time for wire-break monitoring | 9 ms |
| measurement | Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms |
| Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 / 10 |
| Time for offset calibration (per module) | Basic conversion time of the slowest channel |
| Smoothing of measured values: Number of smoothing levels | 4 |
| Smoothing of measured values: parameterizable | Yes |
| Smoothing of measured values: Step: None | Yes |
| Smoothing of measured values: Step: low | Yes |
| Smoothing of measured values: Step: Medium | Yes |
| Smoothing of measured values: Step: High | Yes |
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit |
|---|---|
| Integration and conversion time/resolution per channel: Conversion time (per channel) | 0.5 ms |
| Settling time: for resistive load | 1.5 ms |
| Settling time: for capacitive load | 2.5 ms |
| Settling time: for inductive load | 2.5 ms |
| Connection of signal encoders: for voltage measurement | Yes |
|---|---|
| Connection of signal encoders: for current measurement as 2-wire transducer | Yes |
| Connection of signal encoders: Burden of 2-wire transmitter, max. | 820 Ω |
| Connection of signal encoders: for current measurement as 4-wire transducer | Yes |
| Connection of signal encoders: for resistance measurement with two-wire connection | Yes; Only for PTC |
| Linearity error (relative to input range), (+/-) | 0.02 % |
|---|---|
| Temperature error (relative to input range), (+/-) | 0.005 %/K; With TC type T 0.02 ± % / K |
| Crosstalk between the inputs, max. | -80 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % |
| Output ripple (relative to output range, bandwidth 0 to 50 kHz), | 0.02 % |
| Linearity error (relative to output range), (+/-) | 0.15 % |
|---|---|
| Temperature error (relative to output range), (+/-) | 0.002 %/K |
| Crosstalk between the outputs, max. | -100 dB |
| Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.05 % |
| Temperature error of internal compensation | ±6 °C |
| note regarding accuracy | at temperatures below 0 °C, the figures for operating error and temperature error are doubled |
| Operational error limit in overall temperature range: Voltage, relative to input range, (+/-) | 0.3 % |
| Operational error limit in overall temperature range: Current, relative to input range, (+/-) | 0.3 % |
| Operational error limit in overall temperature range: Resistance, relative to input range, (+/-) | 0.3 % |
| Operational error limit in overall temperature range: Thermocouple, relative to input range, (+/-) | 0.3 %; Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K |
| Basic error limit (operational limit at 25 °C): Voltage, relative to input range, (+/-) | 0.1 % |
| Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) | 0.1 % |
| Basic error limit (operational limit at 25 °C): Resistance, relative to input range, (+/-) | 0.1 % |
| Basic error limit (operational limit at 25 °C): Resistance thermometer, relative to input range, (+/-) | 0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K |
| Basic error limit (operational limit at 25 °C): Thermocouple, relative to input range, (+/-) | 0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency: Series mode interference (peak value of interference < rated value of input range), min. | 40 dB |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Alarms: Limit value alarm | Yes; two upper and two lower limit values in each case |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | Yes; only for input type 1 ... 5 V, 4 ... 20 mA, TC, R, RTD and output type current |
| Diagnoses: Short-circuit | Yes; Only for output type "voltage" |
| Diagnoses: Overflow/Underflow | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | No |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation analog inputs: between the channels | No |
|---|---|
| Potential separation analog inputs: between the channels, in groups of | 4 |
| Potential separation analog inputs: between the channels and backplane bus | Yes |
| Potential separation analog outputs: between the channels | No |
| Potential separation analog outputs: between the channels, in groups of | 2 |
| Potential separation analog outputs: between the channels and backplane bus | Yes |
| between the inputs (UCM) | 20 V DC |
|---|---|
| Between the inputs and MANA (UCM) | 10 V DC |
| between S- and MANA (UCM) | 8 V DC |
| Isolation tested with | 707 V DC (type test) |
|---|
| Siemens Eco Profile (SEP) | Siemens EcoTech |
|---|---|
| Suitable for safety-related tripping of standard modules | No |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 38.6 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 14.4 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 24.6 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.44 kg |
| signed firmware update | No |
|---|---|
| securely removing data | No |
| data integrity | No |
| Ambient temperature during operation: horizontal installation, min. | -25 °C; from FS04 |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -25 °C; from FS04 |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Absolute humidity: dew point, min. | -60 °C; suitable for dry room applications |
| Width | 25 mm |
|---|---|
| Height | 147 mm |
| eClass | 16 27-24-22-01 |
|---|---|
| ETIM | 10 EC001420 |
| IDEA | 4 3562 |
| UNSPSC | 15 32-15-17-05 |
| Miscellaneous Metrological Approval | For use in hazard- |
|---|---|
| General Product Approval | ous locations |
| CCC-Ex NK / Nippon Kaiji Ky- | okai |
|---|
| Net weight | 0.424 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.924 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of AI 4xU/I/RTD/TC /AQ 2xU/I ST is 24 V DC.
The tariff (HS) code on file for AI 4xU/I/RTD/TC /AQ 2xU/I ST is 85389091.
The EAN (GTIN) of AI 4xU/I/RTD/TC /AQ 2xU/I ST is 4047623403326.
AI 4xU/I/RTD/TC /AQ 2xU/I ST ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.