SIMATIC S7-1500

Siemens 6ES7534-7QE00-0AB0 SIMATIC S7-1500 AI 4xU/I/RTD/TC AQ 2xU/I ST PLC I/O Module

Siemens SIMATIC S7-1500 AI 4xU/I/RTD/TC/AQ 2xU/I ST, universal analog module, CiR in RUN.

Rated operational voltage
24 V DC
EAN
4047623403326
Description

About the AI 4xU/I/RTD/TC /AQ 2xU/I ST

The Siemens SIMATIC S7-1500 6ES7534-7QE00-0AB0 (AI 4xU/I/RTD/TC/AQ 2xU/I ST) is a universal analog module combining 4 analog inputs configurable for voltage, current, resistance/RTD, or thermocouple measurement with 2 analog outputs for voltage or current, at 16-bit resolution and 0.3% accuracy. It supports reparameterization and calibration in RUN (CiR) and mounts in a 35 mm S7-1500 backplane slot.

Selection Notes

ST in the designation marks the standard-accuracy variant of this universal module - it accepts voltage, current, RTD/resistance, and thermocouple inputs on the same 4 channels, configured per channel rather than simultaneously in all modes, so one module replaces separate dedicated AI modules when a machine mixes sensor types across a small number of measurement points. Reparameterization and calibration are possible in RUN (CiR), which matters for machines that cannot be stopped to add or recalibrate a sensor channel. The 2 integrated analog outputs mean small closed-loop control, such as a valve positioner, does not need a separate AQ module alongside this one.

Applications

Used for mixed-sensor process measurement - temperature via RTD/TC, pressure or level via 4-20 mA, and position feedback via 0-10 V - combined with 2 analog control outputs on process skids, utilities, and machine sections where sensor types vary point to point.

Specification

Full specification

256 values · Last verified 01 Nov 2026

General information 18

Product type designation AI 4xU/I/RTD/TC /AQ 2xU/I ST
HW functional status from FS01
Firmware version V1.0.0
FW update possible Yes
Product function: I&M data Yes; I&M0 to I&M3
Product function: Isochronous mode No
Product function: Prioritized startup No
Product function: Measuring range scalable No
Product function: Scalable measured values No
Product function: Adjustment of measuring range No
Product function: Output range scalable No
Engineering with: STEP 7 TIA Portal configurable/integrated from version V13 / V13.0.2
Engineering with: STEP 7 configurable/integrated from version V5.5 SP3 / -
Engineering with: PROFIBUS from GSD version/GSD revision V1.0 / V5.1
Engineering with: PROFINET from GSD version/GSD revision V2.3 / -
Operating mode: Oversampling No
Operating mode: MSI Yes
Operating mode: MSO Yes

CiR - Configuration in RUN 2

Reparameterization possible in RUN Yes
Calibration possible in RUN Yes

Supply voltage 4

Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Show all 256 specifications ↓ Show less ↑232 more values in Identification, Input current, Encoder supply, Power, Power loss, Analog inputs, Analog outputs, Analog value generation for the inputs, Analog value generation for the outputs, Encoder, Errors/accuracies, (+/-), Interrupts/diagnostics/status information, Potential separation, Permissible potential difference, Isolation, Standards, approvals, certificates, Security, Ambient conditions, Dimensions, Version Classification, General Product Approval, For use in hazard-Maritime application ous locations, Logistics.

Identification 10

Part number 6ES7534-7QE00-0AB0
Type designation AI 4xU/I/RTD/TC /AQ 2xU/I ST
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4047623403326
ETIM class EC001420
eCl@ss 27242201

Input current 1

Current consumption, max. 200 mA

Encoder supply 2

24 V encoder supply: Short-circuit protection Yes
24 V encoder supply: Output current, max. 20 mA; Max. 47 mA per channel for a duration < 10 s

Power 1

Power consumption from the backplane bus 0.7 W

Power loss 1

Power loss, typ. 3.3 W

Analog inputs 100

Number of analog inputs 4
For current measurement 4
For voltage measurement 4
For resistance/resistance thermometer measurement 2
For thermocouple measurement 4
permissible input voltage for voltage input (destruction limit), max. 28.8 V
permissible input current for current input (destruction limit), max. 40 mA
Constant measurement current for resistance-type transmitter, 150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm,
typ. Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA
Technical unit for temperature measurement adjustable Yes; °C/°F/K
Analog input with oversampling No
Standardization of measured values No
Input ranges (rated values), voltages: 0 to +5 V No
Input ranges (rated values), voltages: 0 to +10 V No
Input ranges (rated values), voltages: 1 V to 5 V Yes
Input ranges (rated values), voltages: Input resistance (1 V to 5 V) 100 kΩ
Input ranges (rated values), voltages: -1 V to +1 V Yes
Input ranges (rated values), voltages: Input resistance (-1 V to +1 V) 10 MΩ
Input ranges (rated values), voltages: -10 V to +10 V Yes
Input ranges (rated values), voltages: Input resistance (-10 V to +10 V) 100 kΩ
Input ranges (rated values), voltages: -2.5 V to +2.5 V Yes
Input ranges (rated values), voltages: Input resistance (-2.5 V to +2.5 V) 10 MΩ
Input ranges (rated values), voltages: -25 mV to +25 mV No
Input ranges (rated values), voltages: -250 mV to +250 mV Yes
Input ranges (rated values), voltages: Input resistance (-250 mV to +250 mV) 10 MΩ
Input ranges (rated values), voltages: -5 V to +5 V Yes
Input ranges (rated values), voltages: Input resistance (-5 V to +5 V) 100 kΩ
Input ranges (rated values), voltages: -50 mV to +50 mV Yes
Input ranges (rated values), voltages: Input resistance (-50 mV to +50 mV) 10 MΩ
Input ranges (rated values), voltages: -500 mV to +500 mV Yes
Input ranges (rated values), voltages: Input resistance (-500 mV to +500 mV) 10 MΩ
Input ranges (rated values), voltages: -80 mV to +80 mV Yes
Input ranges (rated values), voltages: Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents: 0 to 20 mA Yes
Input ranges (rated values), currents: Input resistance (0 to 20 mA) 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), currents: -20 mA to +20 mA Yes
Input ranges (rated values), currents: Input resistance (-20 mA to +20 mA) 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), currents: 4 mA to 20 mA Yes
Input ranges (rated values), currents: Input resistance (4 mA to 20 mA) 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), thermocouples: Type B Yes
Input ranges (rated values), thermocouples: Input resistance (Type B) 10 MΩ
Input ranges (rated values), thermocouples: Type C No
Input ranges (rated values), thermocouples: Type E Yes
Input ranges (rated values), thermocouples: Type J Yes
Input ranges (rated values), thermocouples: Type K Yes
Input ranges (rated values), thermocouples: Type L No
Input ranges (rated values), thermocouples: Type N Yes
Input ranges (rated values), thermocouples: Type R Yes
Input ranges (rated values), thermocouples: Type S Yes
Input ranges (rated values), thermocouples: Type T Yes
Input ranges (rated values), thermocouples: Type U No
Input ranges (rated values), thermocouples: Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometer: Cu 10 No
Input ranges (rated values), resistance thermometer: Cu 10 according to GOST No
Input ranges (rated values), resistance thermometer: Cu 50 No
Input ranges (rated values), resistance thermometer: Cu 50 according to GOST No
Input ranges (rated values), resistance thermometer: Cu 100 No
Input ranges (rated values), resistance thermometer: Cu 100 according to GOST No
Input ranges (rated values), resistance thermometer: Ni 10 No
Input ranges (rated values), resistance thermometer: Ni 10 according to GOST No
Input ranges (rated values), resistance thermometer: Ni 100 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Input resistance (Ni 100) 10 MΩ
Input ranges (rated values), resistance thermometer: Ni 100 according to GOST No
Input ranges (rated values), resistance thermometer: Ni 1000 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Ni 1000 according to GOST No
Input ranges (rated values), resistance thermometer: LG-Ni 1000 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Ni 120 No
Input ranges (rated values), resistance thermometer: Ni 120 according to GOST No
Input ranges (rated values), resistance thermometer: Ni 200 No
Input ranges (rated values), resistance thermometer: Ni 200 according to GOST No
Input ranges (rated values), resistance thermometer: Ni 500 No
Input ranges (rated values), resistance thermometer: Ni 500 according to GOST No
Input ranges (rated values), resistance thermometer: Pt 10 No
Input ranges (rated values), resistance thermometer: Pt 10 according to GOST No
Input ranges (rated values), resistance thermometer: Pt 50 No
Input ranges (rated values), resistance thermometer: Pt 50 according to GOST No
Input ranges (rated values), resistance thermometer: Pt 100 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Pt 100 according to GOST No
Input ranges (rated values), resistance thermometer: Pt 1000 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Pt 1000 according to GOST No
Input ranges (rated values), resistance thermometer: Pt 200 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Pt 200 according to GOST No
Input ranges (rated values), resistance thermometer: Pt 500 Yes; Standard/climate
Input ranges (rated values), resistance thermometer: Pt 500 according to GOST No
Input ranges (rated values), resistors: 0 to 150 ohms Yes
Input ranges (rated values), resistors: Input resistance (0 to 150 ohms) 10 MΩ
Input ranges (rated values), resistors: 0 to 300 ohms Yes
Input ranges (rated values), resistors: Input resistance (0 to 300 ohms) 10 MΩ
Input ranges (rated values), resistors: 0 to 600 ohms Yes
Input ranges (rated values), resistors: Input resistance (0 to 600 ohms) 10 MΩ
Input ranges (rated values), resistors: 0 to 3000 ohms No
Input ranges (rated values), resistors: 0 to 6000 ohms Yes
Input ranges (rated values), resistors: PTC Yes
Input ranges (rated values), resistors: Input resistance (PTC) 10 MΩ
Thermocouple (TC) Temperature compensation: Parameterizable Yes
Thermocouple (TC) Temperature compensation: internal temperature compensation Yes
Thermocouple (TC) Temperature compensation: external temperature compensation via RTD Yes
Thermocouple (TC) Temperature compensation: Compensation for 0 °C reference point temperature Yes; fixed value can be set
Thermocouple (TC) Temperature compensation: Reference channel of the module No
Cable length: shielded, max. 800 m; for U/I, 200 m for R/RTD, 50 m for TC

Analog outputs 18

Number of analog outputs 2
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 24 mA
Current output, no-load voltage, max. 22 V
Cycle time (all channels), min. 3.2 ms; ±0.5 ms, regardless of the number of activated channels
Output ranges, voltage: 0 to 10 V Yes
Output ranges, voltage: 1 V to 5 V Yes
Output ranges, voltage: -5 V to +5 V No
Output ranges, voltage: -10 V to +10 V Yes
Output ranges, current: 0 to 20 mA Yes
Output ranges, current: -20 mA to +20 mA Yes
Output ranges, current: 4 mA to 20 mA Yes
Connection of actuators: for voltage output two-wire connection Yes
Connection of actuators: for voltage output four-wire connection Yes
Connection of actuators: for current output two-wire connection Yes
Load impedance (in rated range of output): with voltage outputs, min. 1 kΩ; 0.5 kOhm at 1 to 5 V
Load impedance (in rated range of output): with current outputs, max. 750 Ω
Cable length: shielded, max. 800 m; for current, 200 m for voltage

Analog value generation for the inputs 14

Measurement principle integrating
Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. 16 bit
Integration and conversion time/resolution per channel: Integration time, parameterizable Yes
Integration and conversion time/resolution per channel: Basic conversion time, including integration time (ms) 9 / 23 / 27 / 107 ms
Integration and conversion time/resolution per channel: additional conversion time for wire-break monitoring 9 ms
measurement Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms
Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10
Time for offset calibration (per module) Basic conversion time of the slowest channel
Smoothing of measured values: Number of smoothing levels 4
Smoothing of measured values: parameterizable Yes
Smoothing of measured values: Step: None Yes
Smoothing of measured values: Step: low Yes
Smoothing of measured values: Step: Medium Yes
Smoothing of measured values: Step: High Yes

Analog value generation for the outputs 5

Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. 16 bit
Integration and conversion time/resolution per channel: Conversion time (per channel) 0.5 ms
Settling time: for resistive load 1.5 ms
Settling time: for capacitive load 2.5 ms
Settling time: for inductive load 2.5 ms

Encoder 5

Connection of signal encoders: for voltage measurement Yes
Connection of signal encoders: for current measurement as 2-wire transducer Yes
Connection of signal encoders: Burden of 2-wire transmitter, max. 820 Ω
Connection of signal encoders: for current measurement as 4-wire transducer Yes
Connection of signal encoders: for resistance measurement with two-wire connection Yes; Only for PTC

Errors/accuracies 5

Linearity error (relative to input range), (+/-) 0.02 %
Temperature error (relative to input range), (+/-) 0.005 %/K; With TC type T 0.02 ± % / K
Crosstalk between the inputs, max. -80 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.02 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz), 0.02 %

(+/-) 16

Linearity error (relative to output range), (+/-) 0.15 %
Temperature error (relative to output range), (+/-) 0.002 %/K
Crosstalk between the outputs, max. -100 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) 0.05 %
Temperature error of internal compensation ±6 °C
note regarding accuracy at temperatures below 0 °C, the figures for operating error and temperature error are doubled
Operational error limit in overall temperature range: Voltage, relative to input range, (+/-) 0.3 %
Operational error limit in overall temperature range: Current, relative to input range, (+/-) 0.3 %
Operational error limit in overall temperature range: Resistance, relative to input range, (+/-) 0.3 %
Operational error limit in overall temperature range: Thermocouple, relative to input range, (+/-) 0.3 %; Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K
Basic error limit (operational limit at 25 °C): Voltage, relative to input range, (+/-) 0.1 %
Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) 0.1 %
Basic error limit (operational limit at 25 °C): Resistance, relative to input range, (+/-) 0.1 %
Basic error limit (operational limit at 25 °C): Resistance thermometer, relative to input range, (+/-) 0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K
Basic error limit (operational limit at 25 °C): Thermocouple, relative to input range, (+/-) 0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency: Series mode interference (peak value of interference < rated value of input range), min. 40 dB

Interrupts/diagnostics/status information 15

Diagnostics function Yes
Substitute values connectable Yes
Alarms: Diagnostic alarm Yes
Alarms: Limit value alarm Yes; two upper and two lower limit values in each case
Diagnoses: Monitoring the supply voltage Yes
Diagnoses: Wire break Yes; only for input type 1 ... 5 V, 4 ... 20 mA, TC, R, RTD and output type current
Diagnoses: Short-circuit Yes; Only for output type "voltage"
Diagnoses: Overflow/Underflow Yes
Diagnostics indication LED: RUN LED Yes; green LED
Diagnostics indication LED: ERROR LED Yes; red LED
Diagnostics indication LED: MAINT LED No
Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) Yes; green LED
Diagnostics indication LED: Channel status display Yes; green LED
Diagnostics indication LED: for channel diagnostics Yes; red LED
Diagnostics indication LED: for module diagnostics Yes; red LED

Potential separation 6

Potential separation analog inputs: between the channels No
Potential separation analog inputs: between the channels, in groups of 4
Potential separation analog inputs: between the channels and backplane bus Yes
Potential separation analog outputs: between the channels No
Potential separation analog outputs: between the channels, in groups of 2
Potential separation analog outputs: between the channels and backplane bus Yes

Permissible potential difference 3

between the inputs (UCM) 20 V DC
Between the inputs and MANA (UCM) 10 V DC
between S- and MANA (UCM) 8 V DC

Isolation 1

Isolation tested with 707 V DC (type test)

Standards, approvals, certificates 7

Siemens Eco Profile (SEP) Siemens EcoTech
Suitable for safety-related tripping of standard modules No
Ecological footprint: environmental product declaration Global warming potential Yes
Ecological footprint: global warming potential, (total) [CO2 eq] 38.6 kg
Ecological footprint: global warming potential, (during production) [CO2 eq] 14.4 kg
Ecological footprint: global warming potential, (during operation) [CO2 eq] 24.6 kg
Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] -0.44 kg

Security 3

signed firmware update No
securely removing data No
data integrity No

Ambient conditions 4

Ambient temperature during operation: horizontal installation, min. -25 °C; from FS04
Ambient temperature during operation: vertical installation, min. -25 °C; from FS04
Altitude during operation relating to sea level: Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Absolute humidity: dew point, min. -60 °C; suitable for dry room applications

Dimensions 2

Width 25 mm
Height 147 mm

Version Classification 4

eClass 16 27-24-22-01
ETIM 10 EC001420
IDEA 4 3562
UNSPSC 15 32-15-17-05

General Product Approval 2

Miscellaneous Metrological Approval For use in hazard-
General Product Approval ous locations

For use in hazard-Maritime application ous locations 1

CCC-Ex NK / Nippon Kaiji Ky- okai

Logistics 6

Net weight 0.424 kg
Country of origin DE
Shipping weight 0.924 kg
Ships from Türkiye
Dispatch 18 Nov
Stock Low stock

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7534-7QE00-0AB0

No documents are on file for this part yet.

Ask us for the datasheet
Quick answers

Questions about the AI 4xU/I/RTD/TC /AQ 2xU/I ST

Which supply voltage is AI 4xU/I/RTD/TC /AQ 2xU/I ST rated for?

The rated operational voltage of AI 4xU/I/RTD/TC /AQ 2xU/I ST is 24 V DC.

What is the HS code of AI 4xU/I/RTD/TC /AQ 2xU/I ST for customs?

The tariff (HS) code on file for AI 4xU/I/RTD/TC /AQ 2xU/I ST is 85389091.

What is the EAN of AI 4xU/I/RTD/TC /AQ 2xU/I ST?

The EAN (GTIN) of AI 4xU/I/RTD/TC /AQ 2xU/I ST is 4047623403326.

Where does AI 4xU/I/RTD/TC /AQ 2xU/I ST ship from, and how fast?

AI 4xU/I/RTD/TC /AQ 2xU/I ST ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC S7-1500

Brand
Siemens
Series
SIMATIC S7-1500
$817.65 Low stock · 18 Nov
Quote

Get a Quote

AI 4xU/I/RTD/TC /AQ 2xU/I ST

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7534-7QE00-0AB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart