- Home
- All Products
- Siemens 6ES7534-7QE00-0AB0 SIMATIC S7-1500 AI 4xU/I/RTD/TC AQ 2xU/I ST PLC I/O Module Siemens 6ES7534-7QE00-0AB0 SIMATIC S7-1500 AI 4xU/I/RTD/TC AQ 2xU/I ST PLC I/O Module
Siemens 6ES7534-7QE00-0AB0 SIMATIC S7-1500 AI 4xU/I/RTD/TC AQ 2xU/I ST PLC I/O Module
Get Quote
- Description
The Siemens SIMATIC S7-1500 6ES7534-7QE00-0AB0 (AI 4xU/I/RTD/TC/AQ 2xU/I ST) is a universal analog module combining 4 analog inputs configurable for voltage, current, resistance/RTD, or thermocouple measurement with 2 analog outputs for voltage or current, at 16-bit resolution and 0.3% accuracy. It supports reparameterization and calibration in RUN (CiR) and mounts in a 35 mm S7-1500 backplane slot.
Technical Specifications
| SKU | 6ES7534-7QE00-0AB0 |
| Brand | Siemens |
| Series | SIMATIC S7-1500 |
| Product Type Designation | AI 4xU/I/RTD/TC/AQ 2xU/I ST |
| Supply Voltage | 24 V DC (permissible range 19.2 ... 28.8 V) |
| Analog Inputs | 4 channels: voltage, current, resistance/RTD, thermocouple |
| Analog Outputs | 2 channels: voltage or current |
| Input Ranges, Voltage | -10 V to +10 V and 7 further ranges down to -50 mV to +50 mV |
| Input Ranges, Current | 0 to 20 mA, 4 to 20 mA, -20 to +20 mA |
| Thermocouple Types Supported | B, E, J, K, N, R, S, T |
| RTD Types Supported | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000, LG-Ni1000 |
| Output Ranges, Voltage | 0 to 10 V, 1 to 5 V, -10 V to +10 V |
| Output Ranges, Current | 0 to 20 mA, 4 to 20 mA, -20 to +20 mA |
| Cycle Time (all channels), Min. | 3.2 ms |
| Cable Length, Shielded, Max. | 800 m (U/I), 200 m (R/RTD), 50 m (TC) |
| Power Consumption, Max. | 200 mA |
| Power Loss, typ. | 3.3 W |
| Net Weight | 0.424 kg |
Selection Notes
ST in the designation marks the standard-accuracy variant of this universal module - it accepts voltage, current, RTD/resistance, and thermocouple inputs on the same 4 channels, configured per channel rather than simultaneously in all modes, so one module replaces separate dedicated AI modules when a machine mixes sensor types across a small number of measurement points. Reparameterization and calibration are possible in RUN (CiR), which matters for machines that cannot be stopped to add or recalibrate a sensor channel. The 2 integrated analog outputs mean small closed-loop control, such as a valve positioner, does not need a separate AQ module alongside this one.
Applications
Used for mixed-sensor process measurement - temperature via RTD/TC, pressure or level via 4-20 mA, and position feedback via 0-10 V - combined with 2 analog control outputs on process skids, utilities, and machine sections where sensor types vary point to point.