Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7532-5HF00-0AB0 is a SIMATIC S7-1500 analog output module, AQ 8xU/I HS, with 8 channels at 16-bit resolution and a 125 µs minimum cycle time. It supports safety-related shutdown of standard load groups up to SIL2 per IEC 62061 and Category 3 / PL d per ISO 13849-1, so one module can carry both standard and safety-relevant analog outputs.
The SIL 2 / Cat. 3, PL d rating covers safety-related shutdown of standard load groups from firmware FS04 onward — check the module's HW functional status before relying on this for a new safety function. 16-bit resolution and a 125 µs cycle time across all 8 channels suit closed-loop analog control loops that need fast, precise setpoints, not just monitoring. Front connectors, screw or push-in, are not included and must be ordered separately, unlike some other S7-1500 I/O modules.
Closed-loop analog output to proportional valves and drives on SIMATIC S7-1500, including applications that need a functional-safety-rated shutdown path for a standard load group.
| Product type designation | AQ 8xU/I HS |
|---|---|
| HW functional status | from FS01 |
| Firmware version | V2.1.0 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | Yes |
| Product function: Prioritized startup | No |
| Product function: Output range scalable | No |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V14 / - |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: Oversampling | Yes |
| Operating mode: MSO | Yes |
| Reparameterization possible in RUN | Yes |
|---|---|
| Calibration possible in RUN | Yes |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Part number | 6ES7532-5HF00-0AB0 |
|---|---|
| Type designation | AQ 8xU/I HS |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4025515080176 |
| ETIM class | EC001420 |
| eCl@ss | 27242201 |
| Current consumption, max. | 260 mA; with 24 V DC supply |
|---|
| Power consumption from the backplane bus | 1.15 W |
|---|
| Power loss, typ. | 7 W |
|---|
| Number of analog outputs | 8 |
|---|---|
| Voltage output, short-circuit protection | Yes |
| Voltage output, short-circuit current, max. | 45 mA |
| Current output, no-load voltage, max. | 20 V |
| Cycle time (all channels), min. | 125 µs; independent of number of activated channels |
| Output ranges, voltage: 0 to 10 V | Yes |
| Output ranges, voltage: 1 V to 5 V | Yes |
| Output ranges, voltage: -5 V to +5 V | No |
| Output ranges, voltage: -10 V to +10 V | Yes |
| Output ranges, current: 0 to 20 mA | Yes |
| Output ranges, current: -20 mA to +20 mA | Yes |
| Output ranges, current: 4 mA to 20 mA | Yes |
| Connection of actuators: for voltage output two-wire connection | Yes |
| Connection of actuators: for voltage output four-wire connection | Yes |
| Connection of actuators: for current output two-wire connection | Yes |
| Load impedance (in rated range of output): with voltage outputs, min. | 1 kΩ |
| Load impedance (in rated range of output): with current outputs, max. | 500 Ω |
| Cable length: shielded, max. | 200 m |
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit |
|---|---|
| Integration and conversion time/resolution per channel: Conversion time (per channel) | 50 µs; independent of number of activated channels |
| Settling time: for resistive load | 30 µs; see additional description in the manual |
| Settling time: for capacitive load | 100 µs; see additional description in the manual |
| Settling time: for inductive load | 100 µs; see additional description in the manual |
| Output ripple (relative to output range, bandwidth 0 to 50 kHz), | 0.02 % |
|---|
| Linearity error (relative to output range), (+/-) | 0.15 % |
|---|---|
| Temperature error (relative to output range), (+/-) | 0.002 %/K |
| Crosstalk between the outputs, max. | -100 dB |
| Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.05 % |
| Operational error limit in overall temperature range: Voltage, relative to output range, (+/-) | 0.3 % |
| Operational error limit in overall temperature range: Current, relative to output range, (+/-) | 0.3 % |
| Basic error limit (operational limit at 25 °C): Voltage, relative to output range, (+/-) | 0.2 % |
| Basic error limit (operational limit at 25 °C): Current, relative to output range, (+/-) | 0.2 % |
| Execution and activation time (TCO), min. | 100 µs |
|---|---|
| Bus cycle time (TDP), min. | 250 µs |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | Yes; Only for output type "current" |
| Diagnoses: Short-circuit | Yes; Only for output type "voltage" |
| Diagnoses: Overflow/Underflow | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation channels: between the channels | No |
|---|---|
| Potential separation channels: between the channels, in groups of | 8 |
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: Between the channels and load voltage L+ | Yes |
| between S- and MANA (UCM) | 8 V DC |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| signed firmware update | No |
|---|---|
| data integrity | No |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; From FS03 |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; From FS03 |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 325 g |
|---|
| Miscellaneous Metrological Approval | For use in hazard- |
|---|---|
| General Product Approval | ous locations |
| Net weight | 0.428 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.928 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of AQ 8xU/I HS is 24 V AC.
The tariff (HS) code on file for AQ 8xU/I HS is 85389091.
The EAN (GTIN) of AQ 8xU/I HS is 4025515080176.
AQ 8xU/I HS ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.