Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7531-7NF00-0AB0 SIMATIC S7-1500 AI 8xU/I HF module reads 8 analog channels configurable for voltage or current, at up to 24-bit resolution with plus/minus 0.1% operational accuracy. It supports measuring-range adjustment and calibration in RUN, draws 55 mA at 19.2 V supply, and dissipates 1.9 W typical, with 16 byte input address space.
The AI 8xU/I HF combines voltage and current inputs on the same 8 channels and reaches up to 24-bit resolution in Fast mode when the project uses scaled REAL format, dropping to 16-bit INTEGER in S7 format — decide the data format before relying on the extra resolution. Its 60 V DC / 30 V AC common-mode voltage rating and 2 000 V DC isolation test between channels, backplane bus, and supply voltage L+ exceed a standard-accuracy analog module, which is the reason to specify the HF variant on installations with mixed ground potentials or tighter channel-to-channel isolation needs. Front connectors, screw-in or push-in, are not included and must be ordered separately.
Fits S7-1500 process I/O needing mixed voltage and current instrumentation on one module: 4-20 mA transmitters, plus/minus 10 V position feedback, and installations where channel isolation matters more than on a standard-accuracy analog module.
| Product type designation | AI 8xU/I HF |
|---|---|
| HW functional status | FS01 |
| Firmware version | V1.1.0 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: Prioritized startup | Yes |
| Product function: Measuring range scalable | No |
| Product function: Scalable measured values | Yes |
| Product function: Adjustment of measuring range | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V14 / - |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: Oversampling | No |
| Operating mode: MSI | Yes |
| Reparameterization possible in RUN | Yes |
|---|---|
| Calibration possible in RUN | Yes |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Part number | 6ES7531-7NF00-0AB0 |
|---|---|
| Type designation | AI 8xU/I HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623406549 |
| ETIM class | EC001420 |
| eCl@ss | 27242201 |
| Current consumption, max. | 50 mA; with 24 V DC supply |
|---|
| Power consumption from the backplane bus | 0.85 W |
|---|
| Power loss, typ. | 1.9 W |
|---|
| Number of analog inputs | 8 |
|---|---|
| For current measurement | 8 |
| For voltage measurement | 8 |
| permissible input voltage for voltage input (destruction limit), max. | 28.8 V |
| permissible input current for current input (destruction limit), max. | 40 mA |
| Input ranges (rated values), voltages: 0 to +5 V | No |
| Input ranges (rated values), voltages: 0 to +10 V | No |
| Input ranges (rated values), voltages: 1 V to 5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (1 V to 5 V) | 100 kΩ |
| Input ranges (rated values), voltages: -10 V to +10 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-10 V to +10 V) | 100 kΩ |
| Input ranges (rated values), voltages: -2.5 V to +2.5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-2.5 V to +2.5 V) | 100 kΩ |
| Input ranges (rated values), voltages: -25 mV to +25 mV | No |
| Input ranges (rated values), voltages: -250 mV to +250 mV | No |
| Input ranges (rated values), voltages: -5 V to +5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-5 V to +5 V) | 100 kΩ |
| Input ranges (rated values), voltages: -50 mV to +50 mV | No |
| Input ranges (rated values), voltages: -500 mV to +500 mV | No |
| Input ranges (rated values), voltages: -80 mV to +80 mV | No |
| Input ranges (rated values), currents: 0 to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (0 to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Input ranges (rated values), currents: -20 mA to +20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (-20 mA to +20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Input ranges (rated values), currents: 4 mA to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (4 mA to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Input ranges (rated values), thermocouples: Type B | No |
| Input ranges (rated values), thermocouples: Type C | No |
| Input ranges (rated values), thermocouples: Type E | No |
| Input ranges (rated values), thermocouples: Type J | No |
| Input ranges (rated values), thermocouples: Type K | No |
| Input ranges (rated values), thermocouples: Type L | No |
| Input ranges (rated values), thermocouples: Type N | No |
| Input ranges (rated values), thermocouples: Type R | No |
| Input ranges (rated values), thermocouples: Type S | No |
| Input ranges (rated values), thermocouples: Type T | No |
| Input ranges (rated values), thermocouples: Type TXK/TXK(L) to GOST | No |
| Input ranges (rated values), resistance thermometer: Cu 10 | No |
| Input ranges (rated values), resistance thermometer: Cu 10 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Cu 50 | No |
| Input ranges (rated values), resistance thermometer: Cu 50 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Cu 100 | No |
| Input ranges (rated values), resistance thermometer: Cu 100 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 10 | No |
| Input ranges (rated values), resistance thermometer: Ni 10 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 100 | No |
| Input ranges (rated values), resistance thermometer: Ni 100 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 1000 | No |
| Input ranges (rated values), resistance thermometer: Ni 1000 according to GOST | No |
| Input ranges (rated values), resistance thermometer: LG-Ni 1000 | No |
| Input ranges (rated values), resistance thermometer: Ni 120 | No |
| Input ranges (rated values), resistance thermometer: Ni 120 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 200 | No |
| Input ranges (rated values), resistance thermometer: Ni 200 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Ni 500 | No |
| Input ranges (rated values), resistance thermometer: Ni 500 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 10 | No |
| Input ranges (rated values), resistance thermometer: Pt 10 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 50 | No |
| Input ranges (rated values), resistance thermometer: Pt 50 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 100 | No |
| Input ranges (rated values), resistance thermometer: Pt 100 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 1000 | No |
| Input ranges (rated values), resistance thermometer: Pt 1000 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 200 | No |
| Input ranges (rated values), resistance thermometer: Pt 200 according to GOST | No |
| Input ranges (rated values), resistance thermometer: Pt 500 | No |
| Input ranges (rated values), resistance thermometer: Pt 500 according to GOST | No |
| Input ranges (rated values), resistors: 0 to 150 ohms | No |
| Input ranges (rated values), resistors: 0 to 300 ohms | No |
| Input ranges (rated values), resistors: 0 to 600 ohms | No |
| Input ranges (rated values), resistors: 0 to 3000 ohms | No |
| Input ranges (rated values), resistors: 0 to 6000 ohms | No |
| Input ranges (rated values), resistors: PTC | No |
| Cable length: shielded, max. | 800 m |
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 24 bit; When using the function "Scaling of the measured values" or "Measuring range adaptation" (32 bit REAL format); 16 bit when using the S7 format (16 bit INTEGER) |
|---|---|
| Integration and conversion time/resolution per channel: Integration time, parameterizable | Yes |
| Integration and conversion time/resolution per channel: Basic conversion time, including integration time (ms) | Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms |
| Integration and conversion time/resolution per channel: Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 / 10 Hz |
| Smoothing of measured values: parameterizable | Yes |
| Smoothing of measured values: Step: None | Yes |
| Smoothing of measured values: Step: low | Yes |
| Smoothing of measured values: Step: Medium | Yes |
| Smoothing of measured values: Step: High | Yes |
| Connection of signal encoders: for voltage measurement | Yes |
|---|---|
| Connection of signal encoders: for current measurement as 2-wire transducer | Yes; with external transmitter supply |
| Connection of signal encoders: for current measurement as 4-wire transducer | Yes |
| Connection of signal encoders: for resistance measurement with two-wire connection | No |
| Linearity error (relative to input range), (+/-) | 0.02 % |
|---|---|
| Temperature error (relative to input range), (+/-) | 0.005 %/K |
| Crosstalk between the inputs, max. | -80 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % |
| Operational error limit in overall temperature range: Voltage, relative to input range, (+/-) | 0.1 % |
| Operational error limit in overall temperature range: Current, relative to input range, (+/-) | 0.1 % |
| Basic error limit (operational limit at 25 °C): Voltage, relative to input range, (+/-) | 0.05 % |
| Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) | 0.05 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency: Series mode interference (peak value of interference < rated value of input range), min. | 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode |
| Diagnostics function | Yes |
|---|---|
| Alarms: Diagnostic alarm | Yes |
| Alarms: Limit value alarm | Yes; two upper and two lower limit values in each case |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | Yes; only for 1 ... 5 V and 4 ... 20 mA |
| Diagnoses: Overflow/Underflow | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation channels: between the channels | Yes |
|---|---|
| Potential separation channels: between the channels, in groups of | 1 |
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: between the channels and the power supply of the electronics | Yes |
| between different circuits | 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels |
|---|
| Isolation tested with | 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus |
|---|
| signed firmware update | No |
|---|---|
| data integrity | No |
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 280 g |
|---|
| ETIM | 10 EC001420 |
|---|---|
| IDEA | 4 3562 |
| UNSPSC | 15 32-15-17-05 |
| Net weight | 0.402 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.902 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of AI 8xU/I HF is 24 V AC.
The tariff (HS) code on file for AI 8xU/I HF is 85389091.
The EAN (GTIN) of AI 8xU/I HF is 4047623406549.
AI 8xU/I HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.