Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7522-5HH00-0AB0 is a SIMATIC S7-1500 digital output module, DQ 16x230VAC/2A ST (relay), packing 16 relay outputs in groups of 2 channels rated 2 A each. It supports safety-related shutdown of load groups up to SIL1 per EN IEC 62061 and Category 2/PL c per EN ISO 13849-1, and it needs a front connector ordered separately.
ST places this relay module in the Standard performance class with channel diagnostics and SIL1/Cat.2/PL c safety-related tripping from FS02 onward, matching the smaller-channel-count DQ 8x230VAC/5A ST relay module in switching technology but doubling the channel count at a lower 2 A per-channel rating. That tradeoff makes this module the better fit when a machine needs many independent AC/DC relay outputs at moderate current, such as valve banks or indicator groups, while the 8-channel/5 A sibling suits fewer, higher-current loads like motor contactor coils. Both accept the same 24-230 V AC/24-120 V DC mixed voltage range per channel, so the choice comes down to channel count versus per-channel current.
Switching multiple mixed AC/DC loads such as valve banks, pilot lights, and small contactor coils up to 2 A per channel, including safety-related shutdown paths rated SIL1/PL c.
| Product type designation | DQ 16x 230 V AC/2 A ST (relay) |
|---|---|
| HW functional status | From FS02 |
| Firmware version | V1.1.0 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: Prioritized startup | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V13 SP1 / - |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: DQ | Yes |
| Operating mode: DQ with energy-saving function | No |
| Operating mode: PWM | No |
| Operating mode: Oversampling | No |
| Operating mode: MSO | Yes |
| Operating mode: Integrated operating cycle counter | Yes; FW V1.1.0 or higher |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Current consumption, max. | 185 mA |
|---|
| Part number | 6ES7522-5HH00-0AB0 |
|---|---|
| Type designation | DQ 16x 230 V AC/2 A ST (relay) |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623404187 |
| ETIM class | EC001419 |
| eCl@ss | 27242204 |
| Rated value (AC) | 230 V; 24 V DC to 120 V DC / 24 V AC to 230 V AC |
|---|
| Power consumption from the backplane bus | 0.8 W |
|---|
| Power loss, typ. | 5 W |
|---|
| Type of digital output | Relays |
|---|---|
| Number of digital outputs | 16 |
| Current-sinking | Yes |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | No |
| Controlling a digital input | Yes; possible |
| Size of motor starters according to NEMA, max. | 5 |
| Switching capacity of the outputs: on lamp load, max. | 50 W (230 V AC), 5 W (24 V DC) |
| Output current: for signal "1" rated value | 2 A |
| Output current: for signal "1" permissible range, min. | 10 mA; 10 V |
| Output current: for signal "1" permissible range, max. | 2 A; thermal continuous current |
| Output current: for signal "0" residual current, max. | 0 A |
| Parallel switching of two outputs: for logic links | Yes |
| Parallel switching of two outputs: for uprating | No |
| Parallel switching of two outputs: for redundant control of a load | Yes |
| Switching frequency: with resistive load, max. | 1 Hz |
| Switching frequency: with inductive load, max. | 0.5 Hz |
| Switching frequency: on lamp load, max. | 1 Hz |
| Total current of the outputs: Current per channel, max. | 2 A; see additional description in the manual |
| Total current of the outputs: Current per group, max. | 4 A; see additional description in the manual |
| Total current of the outputs: Current per module, max. | 32 A; see additional description in the manual |
| Relay outputs: Number of relay outputs | 16 |
| Relay outputs: Rated supply voltage of relay coil L+ (DC) | 24 V |
| Relay outputs: Current consumption of relays (coil current of all relays), typ. | 185 mA |
| Relay outputs: external protection for relay outputs | Miniature circuit breaker B10 / B16 |
| Relay outputs: Contact connection (internal) | No |
| Relay outputs: Number of operating cycles, max. | see additional description in the manual |
| Relay outputs: Relay approved acc. to UL 508 Switching capacity of contacts | No |
| Relay outputs: with inductive load, max. | 2 A; see additional description in the manual |
| Relay outputs: with resistive load, max. | 2 A; see additional description in the manual |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 600 m |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | No |
| Diagnoses: short-circuit | No |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | No |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation channels: between the channels | No |
|---|---|
| Potential separation channels: between the channels, in groups of | 2; Switching of different phases permitted |
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: Between the channels and load voltage L+ | Yes |
| between different circuits | 250 V AC between the channels and the supply voltage L+, 250 V AC between the channels and the backplane bus; 250 V AC between the channel groups (500 V AC when connecting different phases; basic insulation) |
|---|
| Isolation tested with | between the channel groups: 3 100 V DC; between the channels and the backplane bus: 3 100 V DC; between the channels and the supply voltage L+: 3 100 V DC; between the L+ and the backplane bus: 707 V DC (type test) |
|---|
| Suitable for safety functions | No |
|---|
| signed firmware update | No |
|---|---|
| data integrity | No |
| Ambient temperature during operation: horizontal installation, min. | -25 °C; From FS02 |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -25 °C; From FS02 |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 350 g |
|---|
| Net weight | 0.369 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.869 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of DQ 16x 230 V AC/2 A ST (relay) is 2 A.
The rated operational voltage of DQ 16x 230 V AC/2 A ST (relay) is 230 V AC.
The tariff (HS) code on file for DQ 16x 230 V AC/2 A ST (relay) is 85389091.
The EAN (GTIN) of DQ 16x 230 V AC/2 A ST (relay) is 4047623404187.
DQ 16x 230 V AC/2 A ST (relay) ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.