Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7522-5HF00-0AB0 is a SIMATIC S7-1500 digital output module, DQ 8x230VAC/5A ST (relay), with 8 relay outputs wired one per group and rated 5 A at 24-230 V AC/DC. It supports safety-related shutdown of load groups up to SIL1 per EN IEC 62061 and Category 2/PL c per EN ISO 13849-1, and it needs a front connector ordered separately.
ST places this relay module in the Standard performance class with per-channel isolation and diagnostics, plus SIL1/Cat.2/PL c safety-related tripping from FS03 onward, which lets it act inside a safety shutdown path without a dedicated F-module. The relay contact accepts both AC and DC loads on the same channel (24-230 V AC or 24-120 V DC), unlike the Triac output module in the same rack family that is AC-only; pick this one when the load voltage type is mixed or when the 4,000,000-cycle relay life and 5 A switching capacity exceed what a solid-state output card offers. Where switching frequency above 2 Hz or silent operation matters more than raw current, the Triac-based DQ module is the better fit instead.
Switching mixed AC/DC loads such as contactor coils, solenoid valves, and indicator circuits up to 5 A per channel, including installations where the output group forms part of a SIL1/PL c safety function.
| Product type designation | DQ 8x230 V AC/5 A ST (relay) |
|---|---|
| HW functional status | From FS02 |
| Firmware version | V2.1.0 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: Prioritized startup | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V12 / V12 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: DQ | Yes |
| Operating mode: DQ with energy-saving function | No |
| Operating mode: PWM | No |
| Operating mode: Oversampling | No |
| Operating mode: MSO | Yes |
| Operating mode: Integrated operating cycle counter | Yes; FW V2.1.0 or higher |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Current consumption, max. | 80 mA |
|---|
| Part number | 6ES7522-5HF00-0AB0 |
|---|---|
| Type designation | DQ 8x230 V AC/5 A ST (relay) |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4025515079866 |
| ETIM class | EC001419 |
| eCl@ss | 27242204 |
| Rated value (AC) | 230 V; 24 V DC to 120 V DC / 24 V AC to 230 V AC |
|---|
| Power consumption from the backplane bus | 0.8 W |
|---|
| Power loss, typ. | 5 W |
|---|
| Type of digital output | Relays |
|---|---|
| Number of digital outputs | 8 |
| Current-sinking | Yes |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | No |
| Controlling a digital input | Yes; possible |
| Size of motor starters according to NEMA, max. | 5 |
| Switching capacity of the outputs: on lamp load, max. | 1 500 W; 10 000 operating cycles |
| Output current: for signal "1" rated value | 5 A |
| Output current: for signal "1" permissible range, min. | 5 mA; 10 V |
| Output current: for signal "1" permissible range, max. | 8 A; thermal continuous current |
| Output current: for signal "0" residual current, max. | 0 A |
| Parallel switching of two outputs: for logic links | Yes |
| Parallel switching of two outputs: for uprating | No |
| Parallel switching of two outputs: for redundant control of a load | Yes |
| Switching frequency: with resistive load, max. | 2 Hz |
| Switching frequency: with inductive load, max. | 0.5 Hz |
| Switching frequency: on lamp load, max. | 2 Hz |
| Total current of the outputs: Current per channel, max. | 8 A; see additional description in the manual |
| Total current of the outputs: Current per group, max. | 8 A; see additional description in the manual |
| Total current of the outputs: Current per module, max. | 64 A; see additional description in the manual |
| Relay outputs: Number of relay outputs | 8 |
| Relay outputs: Rated supply voltage of relay coil L+ (DC) | 24 V |
| Relay outputs: Current consumption of relays (coil current of all relays), typ. | 80 mA |
| Relay outputs: external protection for relay outputs | With miniature circuit breaker with characteristic B for: cos φ 1.0: 600 A cos φ 0.5 ... 0.7: 900 A with 8 A Diazed fuse: 1 000 A |
| Relay outputs: Contact connection (internal) | No |
| Relay outputs: Number of operating cycles, max. | 4 000 000; see additional description in the manual |
| Relay outputs: Relay approved acc. to UL 508 Switching capacity of contacts | Yes; 250 V AC/5 A g.p.; 120 V AC TV-4 tungsten; A300, R300 |
| Relay outputs: with inductive load, max. | see additional description in the manual |
| Relay outputs: with resistive load, max. | see additional description in the manual |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 600 m |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | No |
| Diagnoses: Short-circuit | No |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | No |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation channels: between the channels | Yes; Switching of different phases permitted |
|---|---|
| Potential separation channels: between the channels, in groups of | 1 |
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: Between the channels and load voltage L+ | Yes |
| between different circuits | 250 V AC between the channels and the supply voltage L+, 250 V AC between the channels and the backplane bus; 250 V AC between the channels (500 V AC when connecting different phases; basic insulation) |
|---|
| Isolation tested with | between the channels: 3 100 V DC; between the channels and the backplane bus: 3 100 V DC; between the channels and the supply voltage L+: 3 100 V DC; between the L+ and the backplane bus: 707 V DC (type test) |
|---|
| Suitable for safety functions | No |
|---|
| signed firmware update | No |
|---|---|
| data integrity | No |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; From FS03 |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; From FS03 |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 350 g |
|---|
| Net weight | 0.399 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.899 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of DQ 8x230 V AC/5 A ST (relay) is 5 A.
The rated operational voltage of DQ 8x230 V AC/5 A ST (relay) is 230 V AC.
The tariff (HS) code on file for DQ 8x230 V AC/5 A ST (relay) is 85389091.
The EAN (GTIN) of DQ 8x230 V AC/5 A ST (relay) is 4025515079866.
DQ 8x230 V AC/5 A ST (relay) ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.