Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7522-1BL01-0AB0 is a SIMATIC S7-1500 digital output module, DQ 32x24VDC/0.5A HF, with 32 transistor outputs in groups of 8, each group fused to 4 A. It supports safety-oriented shutdown of load groups up to SIL 2 per IEC 62061 and PL d, Category 3, per ISO 13849-1. Short-circuit protection is electronically clocked with a typical 1 A response threshold.
This HF, high-feature, variant is the one to specify when downstream load groups need safety-related shutdown without a separate safety PLC or interposing relay: from HW functional status FS02 it supports safety-oriented tripping of standard modules up to SIL 2, PL d, Category 3. Each output group of 8 is fused to 4 A total, so grouping loads within that budget matters when sizing more than a couple of higher-current actuators per group. Choose a non-safety DQ module instead when the safety-related shutdown feature is not required.
Typical uses include driving 24 V DC solenoid valves, contactor coils, and indicator loads on S7-1500 machine controls where load groups must be shut down safely up to PL d / SIL 2, such as guard-interlocked actuator groups on packaging or material-handling equipment.
| Product type designation | DQ 32x24VDC/0.5A HF |
|---|---|
| HW functional status | From FS02 |
| Firmware version | V1.1.0 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | Yes |
| Product function: Prioritized startup | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V13 SP1 / - |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: DQ | Yes |
| Operating mode: DQ with energy-saving function | No |
| Operating mode: PWM | No |
| Operating mode: Cam control (switching at comparison values) | No |
| Operating mode: Oversampling | No |
| Operating mode: MSO | Yes |
| Operating mode: Integrated operating cycle counter | Yes |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes; through internal protection with 7 A per group |
| Current consumption, max. | 60 mA |
|---|
| Part number | 6ES7522-1BL01-0AB0 |
|---|---|
| Type designation | DQ 32x24VDC/0.5A HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623405924 |
| ETIM class | EC001419 |
| eCl@ss | 27242204 |
| Rated value (DC) | 24 V |
|---|
| Power consumption from the backplane bus | 1.1 W |
|---|
| Power loss, typ. | 3.5 W |
|---|
| Address space per module: Inputs | 0 byte; typical, maximum 28 bytes, see manual for details |
|---|---|
| Address space per module: Outputs | 4 byte |
| Type of digital output | Transistor |
|---|---|
| Number of digital outputs | 32 |
| Current-sinking | No |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| output type acc. to IEC 61131, type 0.5 | Yes |
| Short-circuit protection | Yes; Clocked electronically |
| Response threshold, typ. | 1 A |
| Limitation of inductive shutdown voltage to | L+ (-53 V) |
| Controlling a digital input | Yes |
| Digital output functions, parameterizable: Switching tripped by comparison values | No |
| Digital output functions, parameterizable: Digital output with oversampling | No |
| Switching capacity of the outputs: with resistive load, max. | 0.5 A |
| Switching capacity of the outputs: on lamp load, max. | 5 W |
| Load resistance range: lower limit | 48 Ω |
| Load resistance range: upper limit | 12 kΩ |
| Output voltage: for signal "1", min. | L+ (-0.8 V) |
| Output current: for signal "1" rated value | 0.5 A |
| Output current: for signal "1" permissible range, max. | 0.5 A |
| Output current: for signal "0" residual current, max. | 0.5 mA |
| Output delay with resistive load: "0" to "1", max. | 100 µs |
| Output delay with resistive load: "1" to "0", max. | 500 µs |
| Parallel switching of two outputs: for logic links | Yes |
| Parallel switching of two outputs: for uprating | No |
| Parallel switching of two outputs: for redundant control of a load | Yes |
| Switching frequency: with resistive load, max. | 100 Hz |
| Switching frequency: with inductive load, max. | 0.5 Hz; According to IEC 60947-5-1, DC-13 |
| Switching frequency: on lamp load, max. | 10 Hz |
| Total current of the outputs: Current per channel, max. | 0.5 A; see additional description in the manual |
| Total current of the outputs: Current per group, max. | 4 A; see additional description in the manual |
| Total current of the outputs: Current per module, max. | 16 A; see additional description in the manual |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 600 m |
| Execution and activation time (TCO), min. | 70 µs |
|---|---|
| Bus cycle time (TDP), min. | 250 µs |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Alarms: Maintenance interrupt | Yes; maintenance alarm for switching cycle counter |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | Yes |
| Diagnoses: Short-circuit | Yes |
| Diagnoses: Group error | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation channels: between the channels | No |
|---|---|
| Potential separation channels: between the channels, in groups of | 8 |
| Potential separation channels: between the channels and backplane bus | Yes |
| Isolation tested with | 707 V DC (type test) |
|---|
| Siemens Eco Profile (SEP) | Siemens EcoTech |
|---|---|
| Suitable for safety functions | No |
| Suitable for safety-related tripping of standard modules | Yes; From FS02 |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 43.8 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 9.5 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 34.5 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.231 kg |
| Highest safety class achievable for safety-related tripping of standard modules: Performance level according to ISO 13849-1 | PL d |
| signed firmware update | Yes; Firmware V3.0.0 or higher |
|---|---|
| securely removing data | No |
| data integrity | Yes; Firmware V3.0.0 or higher |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; From FS03 |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; From FS03 |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Absolute humidity: dew point, min. | -60 °C; suitable for dry room applications |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 280 g |
|---|
| eClass | 14 27-24-22-04 |
|---|---|
| ETIM | 10 EC001419 |
| IDEA | 4 3566 |
| UNSPSC | 15 32-15-17-05 |
| CCC-Ex NK / Nippon Kaiji Ky- | okai |
|---|
| Net weight | 0.32 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.82 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of DQ 32x24VDC/0.5A HF is 0.5 A.
The rated operational voltage of DQ 32x24VDC/0.5A HF is 24 V AC.
The tariff (HS) code on file for DQ 32x24VDC/0.5A HF is 85389091.
The EAN (GTIN) of DQ 32x24VDC/0.5A HF is 4047623405924.
DQ 32x24VDC/0.5A HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.