Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens SIMATIC S7-1500 digital input module DI 16x24...125V UC HF (6ES7521-7EH00-0AB0) reads 16 channels at 24 V, 48 V, or 125 V AC or DC, grouped in 1, with a parameterizable input delay from 0.05 ms to 20 ms. It also supports 2 channels of up to 6 kHz counting, with front connectors ordered separately.
The UC (universal current) rating means the same module accepts 24 V, 48 V, or 125 V, AC or DC, on its inputs without reconfiguration, so one part number covers mixed-voltage field wiring. HF (high feature) status adds a 2-channel, 6 kHz counter function on channels 0 and 1 on top of standard discrete input duty, and the parameterizable input delay from 0.05 ms up to 20 ms trades noise immunity against response speed per channel group. Front connectors, screw-type or push-in, are ordered separately - factor that into the bill of materials.
Field-level digital sensing across relay contacts, limit switches, and proximity sensors wired at 24-125 V, with the 6 kHz counter channels handling low-speed flow meters or encoder pulse counting alongside standard discrete I/O.
| Product type designation | DI 16x24 ... 125 V UC HF |
|---|---|
| HW functional status | FS01 |
| Firmware version | V1.0.0 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: Prioritized startup | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V13 SP1 / - |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 |
| Engineering with: PROFINET from GSD version/GSD revision | V2.3 / - |
| Operating mode: DI | Yes |
| Operating mode: Counter | No |
| Operating mode: Oversampling | No |
| Operating mode: MSI | Yes |
| Power consumption from the backplane bus | 1.2 W |
|---|
| Power loss, typ. | 2.2 W; At 24 V DC; 6.0 W at 125 V AC |
|---|
| Part number | 6ES7521-7EH00-0AB0 |
|---|---|
| Type designation | DI 16x24 ... 125 V UC HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623406075 |
| ETIM class | EC001419 |
| eCl@ss | 27242204 |
| Number of digital inputs | 16 |
|---|---|
| Digital inputs, parameterizable | Yes |
| Sourcing/sinking input | Yes |
| Input characteristic curve in accordance with IEC 61131, type 3 | Yes; At 24 V DC |
| Input voltage: Rated value (DC) | 24 V; 48 V, 125 V |
| Input voltage: Rated value (AC) | 24 V; 48 V, 125 V (50 - 60 Hz) |
| Input voltage: for signal "0" | -5 ... +5 V |
| Input voltage: for signal "1" | +11 ... +146 V |
| Input current: for signal "1", typ. | 3 mA; At 24 V DC |
| Input delay (for rated value of input voltage) for standard inputs: parameterizable | Yes; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms parameterizable with DC, 20 ms fixed with AC |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 600 m |
| Connectable encoders: 2-wire sensor | Yes |
|---|---|
| Connectable encoders: permissible quiescent current (2-wire sensor), max. | 1.5 mA |
| Diagnostics function | Yes |
|---|---|
| Alarms: Diagnostic alarm | Yes |
| Alarms: Hardware interrupt | Yes |
| Diagnoses: Monitoring the supply voltage | No |
| Diagnoses: Wire break | Yes; To I < 550 µA |
| Diagnoses: short-circuit | No |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | No |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; red LED |
| Potential separation channels: between the channels | Yes |
|---|---|
| Potential separation channels: between the channels, in groups of | 1 |
| Potential separation channels: between the channels and backplane bus | Yes |
| between different circuits | 146 V DC/132 V AC |
|---|
| Isolation tested with | 2 000 V DC |
|---|
| Suitable for safety functions | No |
|---|
| signed firmware update | No |
|---|---|
| data integrity | No |
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| eClass | 16 27-24-22-04 |
|---|---|
| ETIM | 10 EC001419 |
| IDEA | 4 3566 |
| UNSPSC | 15 32-15-17-05 |
| Net weight | 0.322 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.822 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of DI 16x24 ... 125 V UC HF is 24–48–125 or DC V DC.
The tariff (HS) code on file for DI 16x24 ... 125 V UC HF is 85389091.
The EAN (GTIN) of DI 16x24 ... 125 V UC HF is 4047623406075.
DI 16x24 ... 125 V UC HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.