Part number
6ES7518-4JP00-0AB0
Model no
CPU 1518HF-4PN
$12,651.84 On request Dispatch — · From TürkiyeGet a Quote
Manufacturer phase-out

Siemens has announced the end of 6ES7518-4JP00-0AB0

Once production ends, supply depends on remaining stock.

No replacement announced yet. Tell us the application and we will propose an alternative.

SIMATIC S7-1500

Siemens 6ES7518-4JP00-0AB0 SIMATIC S7-1500H CPU 1518HF-4 PN 9MB/60MB Redundant Programmable Logic Controller

SIMATIC S7-1500H CPU 1518HF-4 PN, redundant fail-safe CPU, 9MB program/60MB data memory, PROFINET, H-SYNC.

Rated current
1.55 A
Rated operational voltage
24 V AC
Communication
3x PROFINET (integrated switch), H-SYNC redundancy link, MRP media redundancy, Open IE
Display
6.1 cm screen diagonal
EAN
4047623410973
Description

About the CPU 1518HF-4PN

The Siemens 6ES7518-4JP00-0AB0 is a SIMATIC S7-1500H CPU 1518HF-4 PN, a redundant fail-safe central processing unit with 9 MB of program memory and 60 MB of data memory. It runs in pairs synchronized over H-SYNC on its 4th and 5th interfaces, alongside three PROFINET ports, and requires a SIMATIC Memory Card per CPU.

Selection Notes

The H in this CPU's family marks it for redundant operation: two CPU 1518HF-4 PN units run in a synchronized pair over the dedicated H-SYNC fiber-optic interfaces (4th/5th), so a single CPU fault does not stop the process, unlike a standard non-redundant S7-1500 CPU. The trailing F in the product designation adds fail-safe capability on top of that redundancy, so safety-rated shutdown logic can run on the same redundant pair instead of a separate F-CPU. Against this, the lower connectable-IO-device count (256, versus 512+ on non-H CPUs) and smaller rack (9 modules) reflect that H-system slots are reserved for the synchronization and communication modules the redundant pair needs; applications without a redundancy requirement fit better on a standard S7-1500F CPU.

Applications

Continuous processes where an unplanned CPU stop is unacceptable, such as process lines or utilities where the redundant pair takes over control without interrupting the running program.

Specification

Full specification

267 values · Last verified 01 Nov 2026

General information 8

Product type designation CPU 1518HF-4PN
HW functional status FS04
Firmware version V3.1
FW update possible Yes
Product function: I&M data Yes; I&M0 to I&M3
Product function: Isochronous mode No
Product function: SysLog Yes
Engineering with: STEP 7 TIA Portal configurable/integrated from version V19 (FW V3.1) / V17 (FW V2.9) or higher

Display 1

Screen diagonal [cm] 6.1 cm

Control elements 2

Number of keys 6
Mode selector switch 1
Show all 267 specifications ↓ Show less ↑256 more values in Identification, Supply voltage, Input current, Power, Power loss, Storage, CPU processing times, CPU-blocks, Counters, timers and their retentivity, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Interfaces, 1. Interface, 2. Interface, 3. Interface, 4. Interface, 5. Interface, Interface types, Protocols, S7 message functions, Test commissioning functions, Interrupts/diagnostics/status information, Supported technology objects, Standards, approvals, certificates, Security, Ambient conditions, Configuration, Dimensions, Weights, Logistics.

Identification 8

Part number 6ES7518-4JP00-0AB0
Type designation CPU 1518HF-4PN
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Phase-out announced by the manufacturer
EAN 4047623410973

Supply voltage 6

Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering: Mains/voltage failure stored energy time 5 ms
Mains buffering: Repeat rate, min. 1/s

Input current 4

Current consumption (rated value) 1.55 A
Current consumption, max. 1.95 A
Inrush current, max. 1.95 A; Rated value
I2t 0.4 A2·s

Power 2

Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 30 W

Power loss 1

Power loss, typ. 24 W

Storage 6

Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory: integrated (for program) 9 Mbyte
Work memory: integrated (for data) 60 Mbyte
Load memory: Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup: maintenance-free Yes

CPU processing times 4

for bit operations, typ. 4 ns
for word operations, typ. 6 ns
for fixed point arithmetic, typ. 6 ns
for floating point arithmetic, typ. 24 ns

CPU-blocks 19

Number of elements (total) 20 000; Blocks (OB, FB, FC, DB) and UDTs
DB: Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
DB: Size, max. 16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB: Number range 0 ... 65 535
FB: Size, max. 1 Mbyte
FC: Number range 0 ... 65 535
FC: Size, max. 1 Mbyte
OB: Size, max. 1 Mbyte
OB: Number of free cycle OBs 100
OB: Number of time alarm OBs 20
OB: Number of delay alarm OBs 20
OB: Number of cyclic interrupt OBs 20; with minimum OB 3x cycle of 1 ms
OB: Number of process alarm OBs 50
OB: Number of DPV1 alarm OBs 3
OB: Number of startup OBs 100
OB: Number of asynchronous error OBs 4
OB: Number of synchronous error OBs 2
OB: Number of diagnostic alarm OBs 1
Nesting depth: per priority class 24; Up to 8 possible for F-blocks

Counters, timers and their retentivity 8

S7 counter: Number Retentivity 2 048
S7 counter: adjustable Yes
IEC counter: Number Retentivity Any (only limited by the main memory)
IEC counter: adjustable Yes
S7 timer: Number Retentivity 2 048
S7 timer: adjustable Yes
IEC timer: Number Retentivity Any (only limited by the main memory)
IEC timer: adjustable Yes

Data areas and their retentivity 6

Retentive data area (incl. timers, counters, flags), max. 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
Flag: Size, max. 16 kbyte
Flag: Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks: Retentivity adjustable Yes
Data blocks: Retentivity preset No
Local data: per priority class, max. 64 kbyte; max. 16 KB per block

Address area 6

Number of IO modules 8 192; max. number of modules / submodules
I/O address area: Inputs 32 kbyte; All inputs are in the process image
I/O address area: Outputs per integrated IO subsystem 32 kbyte; All outputs are in the process image
I/O address area: Inputs (volume) 16 kbyte
I/O address area: Outputs (volume) 16 kbyte
Subprocess images: Number of subprocess images, max. 31

Hardware configuration 3

Number of distributed IO systems 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB- Links.
Number of IO Controllers: Integrated 1
Rack: Modules per rack, max. 9; CPU + 2 PS + 6 CP

Time of day 6

Clock: Type Hardware clock
Clock: Backup time 6 wk; At 40 °C ambient temperature, typically
Clock: Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter: Number 16
Clock synchronization: supported Yes
Clock synchronization: on Ethernet via NTP Yes

Interfaces 1

Number of PROFINET interfaces 3

1. Interface 19

Interface types: RJ 45 (Ethernet) Yes; X1
Interface types: Number of ports 2
Interface types: integrated switch Yes
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO Device No
Protocols: SIMATIC communication Yes; Only Server
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
Protocols: Media redundancy Yes
PROFINET IO Controller Services: Isochronous mode No
PROFINET IO Controller Services: IRT No
PROFINET IO Controller Services: Dynamic Frame Packing (DFP) Yes
PROFINET IO Controller Services: PROFIenergy Yes; per user program
PROFINET IO Controller Services: Prioritized startup No
PROFINET IO Controller Services: Number of connectable IO Devices, max. 256
PROFINET IO Controller Services: Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
PROFINET IO Controller Services: PROFINET Security Class Update time for RT 1
PROFINET IO Controller Services: for send cycle of 1 ms 1 ms to 512 ms

2. Interface 10

Interface types: RJ 45 (Ethernet) Yes; X2
Interface types: Number of ports 1
Interface types: integrated switch No
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller No
Protocols: PROFINET IO Device No
Protocols: SIMATIC communication Yes; Only Server
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
Protocols: Media redundancy No

3. Interface 9

Interface types: RJ 45 (Ethernet) Yes; X3
Interface types: Number of ports 1
Interface types: integrated switch No
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller No
Protocols: PROFINET IO device No
Protocols: SIMATIC communication Yes; Only Server
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes

4. Interface 2

Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5

5. Interface 2

Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5

Interface types 5

RJ 45 (Ethernet): 100 Mbps Yes
RJ 45 (Ethernet): 1000 Mbps Yes; Only possible at the X3 interface of the CPU 1518
RJ 45 (Ethernet): Autonegotiation Yes
RJ 45 (Ethernet): Autocrossing Yes
RJ 45 (Ethernet): Industrial Ethernet status LED Yes

Protocols 53

PROFIsafe Yes; V2.4 / V2.6
Number of connections: Number of connections, max. 384; via integrated interfaces of the CPU and connected CPs
Number of connections: Number of connections reserved for ES/HMI/web 10
Number of connections: Number of connections via integrated interfaces 320
Number of connections: Number of S7 routing paths 64
Redundancy mode: PROFINET system redundancy (S2) Yes
Redundancy mode: PROFINET system redundancy (R1) Media redundancy Yes
Redundancy mode: Media redundancy only via 1st interface (X1)
Redundancy mode: MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0
Redundancy mode: MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
Redundancy mode: MRPD No
Redundancy mode: Switchover time on line break, typ. 200 ms; PROFINET MRP
Redundancy mode: Number of stations in the ring, max. 50
SIMATIC communication: PG/OP communication Yes; encryption with TLS V1.3 pre-selected
SIMATIC communication: S7 routing Yes
SIMATIC communication: S7 communication, as server Yes
SIMATIC communication: S7 communication, as client No
Open IE communication: TCP/IP Yes
Open IE communication: Data length, max. 64 kbyte
Open IE communication: several passive connections per port, supported Yes
Open IE communication: ISO-on-TCP (RFC1006) Yes
Open IE communication: UDP Yes
Open IE communication: UDP multicast Yes; 128 multicast circuits (of which max. 5 via X1)
Open IE communication: DHCP No
Open IE communication: DNS Yes
Open IE communication: SNMP Yes
Open IE communication: DCP Yes
Open IE communication: LLDP Yes
Open IE communication: Encryption Yes; Optional
Web server: HTTP No
Web server: HTTPS Yes; only via Web API
Web server: web API Yes
Web server: Number of sessions, max. 200
Web server: number of simultaneous HTTP calls, max. 4
Web server: HTTP request body, max. 131 072 byte
OPC UA: Runtime license required Yes; "Large" license required per CPU
OPC UA: OPC UA Client No
OPC UA: OPC UA Server Yes; Data access (read, write, subscribe), method call, custom address space
OPC UA: Application authentication Yes
OPC UA: Security policies available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
OPC UA: User authentication "anonymous" or by user name & password
OPC UA: GDS support (certificate management) No
OPC UA: Number of sessions, max. 32
OPC UA: Number of subscriptions per session, max. 25
OPC UA: Sampling interval, min. 25 ms
OPC UA: Publishing interval, min. 25 ms
OPC UA: Number of server methods, max. 100
OPC UA: Number of inputs/outputs per server method, max. 20
OPC UA: Number of monitored items, recommended max. 12 000; for 1 s sampling interval and 1 s send interval
OPC UA: Number of server interfaces, max. 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
OPC UA: Number of nodes for user-defined server interfaces, max. 50 000
OPC UA: Alarms and Conditions No
Further protocols: MODBUS Yes; MODBUS TCP

S7 message functions 8

Number of login stations for message functions, max. 64
number of subscriptions, max. 750
number of tags/attributes for subscriptions, max. 50 000
Program alarms Yes
Number of configurable program messages, max. 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max. 10 000
Number of simultaneously active program alarms: Number of program alarms 4 000
Number of simultaneously active program alarms: Number of alarms for system diagnostics 1 000

Test commissioning functions 16

Joint commission (Team Engineering) No
Status block Yes; Up to 16 simultaneously
Single step No
Number of breakpoints 20; Breakpoints are only supported in RUN-Solo status
Status/control: Status/control variable Yes; without fail-safe
Status/control: Variables inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
Number of variables, max.: of which status variables, max. 200; per job
Number of variables, max.: of which control variables, max. 200; per job
Forcing: Forcing Yes; without fail-safe
Forcing: Forcing, variables peripheral inputs/outputs (without fail-safe)
Forcing: Number of variables, max. 200
Diagnostic buffer: present Yes
Diagnostic buffer: Number of entries, max. 3 200
Diagnostic buffer: of which powerfail-proof 1 000
Traces: Number of configurable Traces 8
Traces: Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information 4

Diagnostics indication LED: RUN/STOP LED Yes
Diagnostics indication LED: ERROR LED Yes
Diagnostics indication LED: MAINT LED Yes
Diagnostics indication LED: Connection display LINK TX/RX Yes

Supported technology objects 5

Motion Control No
Controller: PID_Compact Yes; Universal PID controller with integrated optimization
Controller: PID_3Step Yes; PID controller with integrated optimization for valves
Controller: PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring Yes

Standards, approvals, certificates 9

Ecological footprint: environmental product declaration Global warming potential Yes
Ecological footprint: global warming potential, (total) [CO2 eq] 570 kg
Ecological footprint: global warming potential, (during production) [CO2 eq] 96.9 kg
Ecological footprint: global warming potential, (during operation) [CO2 eq] 483 kg
Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] -9.97 kg
Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 PLe
Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) SIL 3
Highest safety class achievable in safety mode: Low demand mode: PFDavg in accordance with SIL3 < 2.00E-05
Highest safety class achievable in safety mode: High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09

Security 1

PROFINET Security Class 1

Ambient conditions 5

Ambient temperature during operation: horizontal installation, min. 0 °C
Ambient temperature during operation: vertical installation, min. 0 °C
Ambient temperature during storage/transportation: min. -40 °C
Ambient temperature during storage/transportation: max. 70 °C
Altitude during operation relating to sea level: Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual

Configuration 18

Programming Programming language: LAD Yes; incl. failsafe
Programming Programming language: FBD Yes; incl. failsafe
Programming Programming language: STL Yes
Programming Programming language: SCL Yes
Programming Programming language: CFC Yes; either CFC or failsafe functionality
Programming Programming language: GRAPH Yes
Know-how protection: User program protection/password protection Yes
Know-how protection: Copy protection No
Know-how protection: Block protection Yes
Access protection: protection of confidential configuration data Yes
Access protection: Password for display Yes
Access protection: Protection level: Write protection Yes
Access protection: Protection level: Read/write protection Yes
Access protection: Protection level: Write protection for Failsafe Yes
Access protection: Protection level: Complete protection Yes
Access protection: User administration Yes
Cycle time monitoring: lower limit adjustable minimum cycle time
Cycle time monitoring: upper limit adjustable maximum cycle time

Dimensions 3

Width 210 mm
Height 147 mm
Depth 129 mm

Weights 1

Weight, approx. 2 116 g

Logistics 6

Net weight 2.299 kg
Country of origin DE
Shipping weight 2.799 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7518-4JP00-0AB0

No documents are on file for this part yet.

Ask us for the datasheet
Quick answers

Questions about the CPU 1518HF-4PN

What is the rated current of CPU 1518HF-4PN?

The rated current of CPU 1518HF-4PN is 1.55 A.

Which supply voltage is CPU 1518HF-4PN rated for?

The rated operational voltage of CPU 1518HF-4PN is 24 V AC.

What is the HS code of CPU 1518HF-4PN for customs?

The tariff (HS) code on file for CPU 1518HF-4PN is 85371091.

What is the EAN of CPU 1518HF-4PN?

The EAN (GTIN) of CPU 1518HF-4PN is 4047623410973.

Where does CPU 1518HF-4PN ship from, and how fast?

CPU 1518HF-4PN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC S7-1500

Brand
Siemens
Series
SIMATIC S7-1500
$12,651.84 On request
Get a Quote
Quote

Get a Quote

CPU 1518HF-4PN

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7518-4JP00-0AB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart