How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7518-4FP00-0AB0 is a SIMATIC S7-1500F CPU 1518F-4 PN/DP, a fail-safe central processing unit with 9 MB of program memory and 60 MB of data memory. It offers four interfaces: PROFINET IRT with a 2-port switch, PROFINET RT, PROFINET basic services, and PROFIBUS, giving it both PROFINET and PROFIBUS connectivity in one CPU. A SIMATIC Memory Card is required to operate it.
The F suffix marks this CPU as fail-safe, rated for use in SIL/PL safety programs alongside standard control logic, so it replaces a separate safety PLC in mixed standard/safety applications. The integrated PROFIBUS DP master on the fourth interface is the differentiator versus a PN-only F-CPU in the same family: it lets the controller keep existing PROFIBUS field devices in service while running PROFINET IRT for new IO, useful in retrofit projects. Against the higher-memory 1518-4 PN/DP variants without the F suffix, this one trades some throughput headroom for certified fail-safe program execution; plants with no safety-rated IO on this controller do not need the F variant.
Mixed standard and safety control on machines or lines still running legacy PROFIBUS devices alongside newer PROFINET IO, where safety shutdown logic runs on the same CPU as the process control program.
| Product type designation | CPU 1518F-4PN/DP |
|---|---|
| HW functional status | FS11 |
| Firmware version | V3.1 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central) |
| Product function: SysLog | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V19 (FW V3.1); V13 (FW V1.5) or higher |
| via dataset | Yes |
|---|
| Screen diagonal [cm] | 6.1 cm |
|---|
| Part number | 6ES7518-4FP00-0AB0 |
|---|---|
| Type designation | CPU 1518F-4PN/DP |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4047623402480 |
| Number of keys | 6 |
|---|---|
| Mode selector switch | 1 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 5 ms |
| Mains buffering: Repeat rate, min. | 1/s |
| Current consumption (rated value) | 1.55 A |
|---|---|
| Current consumption, max. | 1.9 A |
| Inrush current, max. | 1.9 A; Rated value |
| I2t | 0.4 A2·s |
| Infeed power to the backplane bus | 12 W |
|---|---|
| Power consumption from the backplane bus (balanced) | 30 W |
| Power loss, typ. | 24 W |
|---|
| Number of slots for SIMATIC memory card | 1 |
|---|---|
| SIMATIC memory card required | Yes |
| Work memory: integrated (for program) | 9 Mbyte |
| Work memory: integrated (for data) | 60 Mbyte |
| Load memory: Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
| Backup: maintenance-free | Yes |
| for bit operations, typ. | 1 ns |
|---|---|
| for word operations, typ. | 2 ns |
| for fixed point arithmetic, typ. | 2 ns |
| for floating point arithmetic, typ. | 6 ns |
| Number of elements (total) | 20 000; Blocks (OB, FB, FC, DB) and UDTs |
|---|---|
| DB: Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 |
| DB: Size, max. | 16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
| FB: Number range | 0 ... 65 535 |
| FB: Size, max. | 1 Mbyte |
| FC: Number range | 0 ... 65 535 |
| FC: Size, max. | 1 Mbyte |
| OB: Size, max. | 1 Mbyte |
| OB: Number of free cycle OBs | 100 |
| OB: Number of time alarm OBs | 20 |
| OB: Number of delay alarm OBs | 20 |
| OB: Number of cyclic interrupt OBs | 20; with minimum OB 3x cycle of 100 µs |
| OB: Number of process alarm OBs | 50 |
| OB: Number of DPV1 alarm OBs | 3 |
| OB: Number of isochronous mode OBs | 3 |
| OB: Number of technology synchronous alarm OBs | 2 |
| OB: Number of startup OBs | 100 |
| OB: Number of asynchronous error OBs | 4 |
| OB: Number of synchronous error OBs | 2 |
| OB: Number of diagnostic alarm OBs | 1 |
| Nesting depth: per priority class | 24; Up to 8 possible for F-blocks |
| S7 counter: Number Retentivity | 2 048 |
|---|---|
| S7 counter: adjustable | Yes |
| IEC counter: Number Retentivity | Any (only limited by the main memory) |
| IEC counter: adjustable | Yes |
| S7 timer: Number Retentivity | 2 048 |
| S7 timer: adjustable | Yes |
| IEC timer: Number Retentivity | Any (only limited by the main memory) |
| IEC timer: adjustable | Yes |
| Retentive data area (incl. timers, counters, flags), max. | 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB |
|---|---|
| Extended retentive data area (incl. timers, counters, flags), max. | 20 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
| Flag: Size, max. | 16 kbyte |
| Flag: Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks: Retentivity adjustable | Yes |
| Data blocks: Retentivity preset | No |
| Local data: per priority class, max. | 64 kbyte; max. 16 KB per block |
| Number of IO modules | 16 384; max. number of modules / submodules |
|---|---|
| I/O address area: Inputs | 32 kbyte; All inputs are in the process image |
| I/O address area: Outputs per integrated IO subsystem | 32 kbyte; All outputs are in the process image |
| I/O address area: Inputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 |
| I/O address area: Outputs (volume) per CM/CP | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 |
| I/O address area: Outputs (volume) | 8 kbyte |
| Subprocess images: Number of subprocess images, max. | 32 |
| Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
|---|---|
| Number of DP masters: integrated | 1 |
| Number of DP masters: Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
| Number of IO Controllers: Integrated | 2 |
| Number of IO Controllers: via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
| Rack: Modules per rack, max. | 32; CPU + 31 modules |
| Rack: Number of lines, max. | 1 |
| PtP CM: Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
| Clock: Type | Hardware clock |
|---|---|
| Clock: Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Clock: Deviation per day, max. | 10 s; Typ.: 2 s |
| Operating hours counter: Number | 16 |
| Clock synchronization: supported | Yes |
| Clock synchronization: to DP, master | Yes |
| Clock synchronization: on DP, device | Yes |
| Clock synchronization: in AS, master | Yes |
| Clock synchronization: in AS, device | Yes |
| Clock synchronization: on Ethernet via NTP | Yes |
| Number of PROFINET interfaces | 3 |
|---|---|
| Number of PROFIBUS interfaces | 1 |
| 1. Interface Interface types: RJ 45 (Ethernet) | Yes; X1 |
| 1. Interface Interface types: Number of ports | 2 |
| 1. Interface Interface types: integrated switch | Yes |
| Protocols: IP protocol | Yes; IPv4 |
| Protocols: PROFINET IO Controller | Yes |
| Protocols: PROFINET IO Device | Yes |
| Protocols: SIMATIC communication | Yes |
| Protocols: Open IE communication | Yes; Optionally also encrypted |
| Protocols: Web server | Yes |
| Protocols: Media redundancy | Yes |
| PROFINET IO Controller Services: Isochronous mode | Yes |
| PROFINET IO Controller Services: Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| PROFINET IO Controller Services: IRT | Yes |
| PROFINET IO Controller Services: Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Controller Services: PROFIenergy | Yes; per user program |
| PROFINET IO Controller Services: Prioritized startup | Yes; Max. 32 PROFINET devices |
| PROFINET IO Controller Services: Number of connectable IO Devices, max. | 512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| PROFINET IO Controller Services: Of which IO devices with IRT, max. | 64 |
| PROFINET IO Controller Services: of which in line, max. | 512 |
| PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| PROFINET IO Controller Services: Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller Services: Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET IO Controller Services: PROFINET Security Class Update time for IRT | 1 |
| PROFINET IO Controller Services: for send cycle of 125 µs | 125 µs |
| PROFINET IO Controller Services: for send cycle of 187.5 µs | 187.5 µs |
| PROFINET IO Controller Services: for send cycle of 250 µs | 250 µs to 4 ms |
| PROFINET IO Controller Services: for send cycle of 500 µs | 500 µs to 8 ms |
| PROFINET IO Controller Services: for send cycle of 1 ms | 1 ms to 16 ms |
| PROFINET IO Controller Services: for send cycle of 2 ms | 2 ms to 32 ms |
| PROFINET IO Controller Services: for send cycle of 4 ms | 4 ms to 64 ms |
| PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) |
| PROFINET IO Device Services: Isochronous mode | No |
| PROFINET IO Device Services: IRT | Yes; Minimum send cycle of 250 µs |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Device Services: PROFIenergy | Yes; per user program |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 4 |
| PROFINET IO Device Services: activation/deactivation of I-devices | Yes; per user program |
| PROFINET IO Device Services: Asset management record | Yes; per user program |
| PROFINET IO Device Services: PROFINET Security Class | SNMP Configuration and DCP Read Only |
| Interface types: RJ 45 (Ethernet) | Yes; X2 |
|---|---|
| Interface types: Number of ports | 1 |
| Interface types: integrated switch | No |
| Protocols: IP protocol | Yes; IPv4 |
| Protocols: PROFINET IO Controller | Yes |
| Protocols: PROFINET IO Device | Yes |
| Protocols: SIMATIC communication | Yes |
| Protocols: Open IE communication | Yes; Optionally also encrypted |
| Protocols: Web server | Yes |
| Protocols: Media redundancy | No |
| PROFINET IO Controller Services: Isochronous mode | No |
| PROFINET IO Controller Services: Direct data exchange | No |
| PROFINET IO Controller Services: IRT | No |
| PROFINET IO Controller Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Controller Services: PROFIenergy | Yes; per user program |
| PROFINET IO Controller Services: Prioritized startup | No |
| PROFINET IO Controller Services: Number of connectable IO Devices, max. | 128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| PROFINET IO Controller Services: of which in line, max. | 128 |
| PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| PROFINET IO Controller Services: IO Devices changing during operation (partner ports), supported | Yes |
| PROFINET IO Controller Services: Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller Services: Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET IO Controller Services: PROFINET Security Class Update time for RT | 1 |
| PROFINET IO Controller Services: for send cycle of 1 ms | 1 ms to 512 ms |
| PROFINET IO Device Services: Isochronous mode | No |
| PROFINET IO Device Services: IRT | No |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Device Services: PROFIenergy | Yes; per user program |
| PROFINET IO Device Services: Prioritized startup | No |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 4 |
| PROFINET IO Device Services: activation/deactivation of I-devices | Yes; per user program |
| PROFINET IO Device Services: Asset management record | Yes; per user program |
| PROFINET IO Device Services: PROFINET Security Class | SNMP Configuration and DCP Read Only |
| Interface types: RJ 45 (Ethernet) | Yes; X3 |
|---|---|
| Interface types: Number of ports | 1 |
| Interface types: integrated switch | No |
| Protocols: IP protocol | Yes; IPv4 |
| Protocols: PROFINET IO Controller | No |
| Protocols: PROFINET IO Device | No |
| Protocols: SIMATIC communication | Yes |
| Protocols: Open IE communication | Yes; Optionally also encrypted |
| Protocols: Web server | Yes |
| Interface types: RS 485 | Yes; X4 |
|---|---|
| Interface types: Number of ports | 1 |
| Protocols: PROFIBUS DP master | Yes |
| Protocols: PROFIBUS DP device | No |
| Protocols: SIMATIC communication | Yes |
| PROFIBUS DP master: Number of connections, max. | 48; for the integrated PROFIBUS DP interface |
| PROFIBUS DP master: max. number of DP devices Services | 125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| PROFIBUS DP master: Equidistance | Yes |
| PROFIBUS DP master: Isochronous mode | Yes |
| PROFIBUS DP master: activation/deactivation of DP devices | Yes |
| RJ 45 (Ethernet): 100 Mbps | Yes |
|---|---|
| RJ 45 (Ethernet): 1000 Mbps | Yes; Only possible at the X3 interface of the CPU 1518 |
| RJ 45 (Ethernet): Autonegotiation | Yes |
| RJ 45 (Ethernet): Autocrossing | Yes |
| RJ 45 (Ethernet): Industrial Ethernet status LED | Yes |
| RS 485: Transmission rate, max. | 12 Mbit/s |
| PROFIsafe | Yes; V2.4 / V2.6 |
|---|---|
| Number of connections: Number of connections, max. | 384; via integrated interfaces of the CPU and connected CPs / CMs |
| Number of connections: Number of connections reserved for ES/HMI/web | 10 |
| Number of connections: Number of connections via integrated interfaces | 320 |
| Number of connections: Number of S7 routing paths | 64; in total, only 16 S7-Routing connections are supported via PROFIBUS |
| Redundancy mode: PROFINET system redundancy (S2) | No |
| Redundancy mode: PROFINET system redundancy (R1) | No |
| Redundancy mode: H-Sync forwarding Media redundancy | Yes |
| Redundancy mode: Media redundancy | only via 1st interface (X1) |
| Redundancy mode: MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
| Redundancy mode: MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| Redundancy mode: MRPD | Yes; Requirement: IRT |
| Redundancy mode: Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Redundancy mode: Number of stations in the ring, max. | 50 |
| SIMATIC communication: PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| SIMATIC communication: S7 routing | Yes |
| SIMATIC communication: Data record routing | Yes |
| SIMATIC communication: S7 communication, as server | Yes |
| SIMATIC communication: S7 communication, as client | Yes |
| SIMATIC communication: User data per job, max. | See online help (S7 communication, user data size) |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: Data length, max. | 64 kbyte |
| Open IE communication: several passive connections per port, supported | Yes |
| Open IE communication: ISO-on-TCP (RFC1006) | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: UDP multicast | Yes; 128 multicast circuits (of which max. 5 via X1) |
| Open IE communication: DHCP | Yes |
| Open IE communication: DNS | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: DCP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: Encryption | Yes; Optional |
| Web server: HTTP | Yes; Standard and user pages |
| Web server: HTTPS | Yes; Standard and user pages |
| web API: Number of sessions, max. | 200 |
| web API: number of simultaneous HTTP calls, max. | 4 |
| web API: HTTP request body, max. | 131 072 byte |
| OPC UA: Runtime license required | Yes; "Large" license required |
| OPC UA: OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| OPC UA: Application authentication | Yes |
| OPC UA: Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| OPC UA: User authentication | "anonymous" or by user name & password |
| OPC UA: Number of connections, max. | 40 |
| OPC UA: Number of nodes of the client interfaces, recommended max. | 5 000 |
| Number of elements for one call of 300 OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.: Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
| Further protocols: MODBUS | Yes; MODBUS TCP |
| Equidistance | Yes |
|---|
| Number of login stations for message functions, max. | 64 |
|---|---|
| number of subscriptions, max. | 750 |
| number of tags/attributes for subscriptions, max. | 50 000 |
| Program alarms | Yes |
| Number of configurable program messages, max. | 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
| Number of loadable program messages in RUN, max. | 10 000 |
| Number of simultaneously active program alarms: Number of program alarms | 4 000 |
| Number of simultaneously active program alarms: Number of alarms for system diagnostics | 1 000 |
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 10 engineering systems |
|---|---|
| Status block | Yes; Up to 16 simultaneously (in total across all ES clients) |
| Single step | No |
| Number of breakpoints | 20 |
| Profiling | No |
| Status/control: Status/control variable | Yes; without fail-safe |
| Status/control: Variables | inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters |
| Number of variables, max.: of which status variables, max. | 200; per job |
| Number of variables, max.: of which control variables, max. | 200; per job |
| Forcing: Forcing | Yes; without fail-safe |
| Forcing: Forcing, variables | peripheral inputs/outputs (without fail-safe) |
| Forcing: Number of variables, max. | 200 |
| Diagnostic buffer: present | Yes |
| Diagnostic buffer: Number of entries, max. | 3 200 |
| Diagnostic buffer: of which powerfail-proof | 1 000 |
| Traces: Number of configurable Traces | 8 |
| Traces: Memory size per trace, max. | 512 kbyte |
| Diagnostics indication LED: RUN/STOP LED | Yes |
|---|---|
| Diagnostics indication LED: ERROR LED | Yes |
| Diagnostics indication LED: MAINT LED | Yes |
| Diagnostics indication LED: Connection display LINK TX/RX | Yes |
| Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
|---|---|
| Number of available Motion Control resources for technology objects | 15 360 |
| Required Motion Control resources: per speed-controlled axis | 40 |
| Required Motion Control resources: per positioning axis | 80 |
| Required Motion Control resources: per synchronous axis | 160 |
| Required Motion Control resources: per external encoder | 80 |
| Required Motion Control resources: per output cam | 20 |
| Required Motion Control resources: per cam track | 160 |
| Required Motion Control resources: per probe | 40 |
| Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) | 140 |
| Controller: PID_Compact | Yes; Universal PID controller with integrated optimization |
| Controller: PID_3Step | Yes; PID controller with integrated optimization for valves |
| Controller: PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring: High-speed counter | Yes |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
|---|---|
| Ecological footprint: global warming potential, (total) [CO2 eq] | 570 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 96.9 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 483 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -9.97 kg |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | PLe |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) | SIL 3 |
| Highest safety class achievable in safety mode: Low demand mode: PFDavg in accordance with SIL3 | < 2.00E-05 |
| Highest safety class achievable in safety mode: High demand/continuous mode: PFH in accordance with SIL3 | < 1.00E-09 |
| PROFINET Security Class | 1 |
|---|
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Ambient temperature during storage/transportation: min. | -40 °C |
| Ambient temperature during storage/transportation: max. | 70 °C |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Programming Programming language: LAD | Yes; incl. failsafe |
|---|---|
| Programming Programming language: FBD | Yes; incl. failsafe |
| Programming Programming language: STL | Yes |
| Programming Programming language: SCL | Yes |
| Programming Programming language: CFC | Yes; either CFC or failsafe functionality |
| Programming Programming language: GRAPH | Yes |
| Know-how protection: User program protection/password protection | Yes |
| Know-how protection: Copy protection | Yes |
| Know-how protection: Block protection | Yes |
| Access protection: protection of confidential configuration data | Yes |
| Access protection: Password for display | Yes |
| Access protection: Protection level: Write protection | Yes |
| Access protection: Protection level: Read/write protection | Yes |
| Access protection: Protection level: Write protection for Failsafe | Yes |
| Access protection: Protection level: Complete protection | Yes |
| Access protection: User administration | Yes; device-wide |
| Cycle time monitoring: lower limit | adjustable minimum cycle time |
| Cycle time monitoring: upper limit | adjustable maximum cycle time |
| Width | 175 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 2 079 g |
|---|
| Miscellaneous Manufacturer Declara- Miscellaneous | tion |
|---|---|
| TUEV China RoHS Manufacturer Declara- | tion |
| Net weight | 2.223 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 2.723 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CPU 1518F-4PN/DP is 1.55 A.
The rated operational voltage of CPU 1518F-4PN/DP is 24 V AC.
The tariff (HS) code on file for CPU 1518F-4PN/DP is 85371091.
The EAN (GTIN) of CPU 1518F-4PN/DP is 4047623402480.
CPU 1518F-4PN/DP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.