- Home
- All Products
- Siemens 6ES7515-2FN03-0AB0 SIMATIC S7-1500F CPU 1515F-2 PN 1.5MB/4.5MB Programmable Logic Controller Siemens 6ES7515-2FN03-0AB0 SIMATIC S7-1500F CPU 1515F-2 PN 1.5MB/4.5MB Programmable Logic Controller
Siemens 6ES7515-2FN03-0AB0 SIMATIC S7-1500F CPU 1515F-2 PN 1.5MB/4.5MB Programmable Logic Controller
Get Quote
- Description
The Siemens 6ES7515-2FN03-0AB0 is a SIMATIC S7-1500F fail-safe CPU (CPU 1515F-2 PN) with 1.5 MB of work memory for program and 4.5 MB for data, plus two PROFINET interfaces — the first with IRT and a 2-port switch, the second running RT. It processes bit operations in 6 ns typical and connects up to 256 IO devices, of which 64 can run IRT.
Technical Specifications
| SKU | 6ES7515-2FN03-0AB0 |
| Brand | Siemens |
| Series | SIMATIC S7-1500F |
| Product Type Designation | CPU 1515F-2 PN |
| HW Functional Status | FS04 |
| Firmware Version | V4.1 |
| Work Memory, program | 1.5 Mbyte |
| Work Memory, data | 4.5 Mbyte |
| Load Memory, plug-in SIMATIC Memory Card, max. | 32 Gbyte |
| Bit Operation Processing Time, typ. | 6 ns |
| Word Operation Processing Time, typ. | 7 ns |
| Supply Voltage | 24 V DC (19.2 ... 28.8 V) |
| Current Consumption, rated | 0.65 A |
| Power Loss, typ. | 3.6 W |
| PROFINET Interfaces | 2; 1st IRT with 2-port switch, 2nd RT |
| Integrated IO Controllers | 2 |
| Protocols | PROFINET IO Controller, PROFINET IO Device, IPv4, Web server, Media redundancy |
| Isochronous Mode | Yes; 375 µs distributed / 1 ms central minimum cycle |
| Max. Connectable IO Devices | 256; of which 64 with IRT |
| SIMATIC Memory Card | Required, 1 slot |
| Net Weight | 0.511 kg |
Selection Notes
The second PROFINET interface (RT, not IRT) lets this CPU separate device traffic from plant-network traffic — the first interface's IRT and 2-port switch handle time-critical distributed I/O, while the second interface connects to SCADA, engineering, or IT-side systems without competing for isochronous bandwidth. At 1.5 MB program / 4.5 MB data memory and 256 connectable IO devices (64 with IRT), it covers larger PROFINET stations than a single-interface S7-1500F CPU. The integrated fail-safe capability keeps safety logic on the same CPU as standard control, avoiding a separate safety controller.
Applications
Larger PROFINET-based machines or process lines that need both a time-critical IRT segment for drives and I/O and a separate RT-only interface for plant network or SCADA connectivity, with fail-safe functions integrated on the same CPU. Suited to multi-cell lines where isochronous motion and general networking must not share the same PROFINET segment.