Part number
6ES7513-2PM03-0AB0
Model no
CPU 1513pro-2 PN
$2,265.62 On request Dispatch — · From TürkiyeGet a Quote
SIMATIC S7-1500

Siemens 6ES7513-2PM03-0AB0 SIMATIC S7-1500 CPU 1513pro-2 PN 600KB/2.5MB Programmable Logic Controller

Siemens CPU 1513pro-2 PN PLC for ET 200pro, 600KB/2.5MB memory, IP65/67, dual PROFINET IRT/RT

Rated current
0.22 A
Rated operational voltage
24 V DC
Communication
2x PROFINET (IRT with 3-port switch + RT), PROFINET IO Controller/Device, Open IE, Web server
EAN
4047623414216
Description

About the CPU 1513pro-2 PN

Siemens ships the 6ES7513-2PM03-0AB0 as the CPU 1513pro-2 PN, a standard central processing unit for the SIMATIC ET 200pro distributed I/O station. It carries 600 KB of work memory for the program and 2.5 MB for data, and its IP65/67 housing mounts directly in the field on a connection module rather than inside a control cabinet.

Selection Notes

This is the non-fail-safe CPU in the 1513pro range: it runs the standard user program only, so choose the F variant instead when the ET 200pro station has safety-rated I/O to supervise. 600 KB of program memory and 2.5 MB of data memory suit machines with a moderate block count; move up to the higher-memory pro CPU in the same family once the project outgrows that budget. The IP65/67 rating and connection-module mounting put the CPU on the machine itself, avoiding a separate control cabinet for the I/O station.

Specification

Full specification

300 values · Last verified 01 Nov 2026

General information 8

Product type designation CPU 1513pro-2 PN
HW functional status FS01
Firmware version V4.0
FW update possible Yes
Product function: I&M data Yes; I&M0 to I&M3
Product function: Isochronous mode Yes; Via X1, with minimum OB 6x cycle of 500 µs
Product function: SysLog Yes
Engineering with: STEP 7 TIA Portal configurable/integrated from version V20 (FW V4.0) / V19 (FW V3.1) or higher; configurable with older TIA Portal versions as 6ES7513-2PL00-0AB0

Configuration control 1

via dataset No

Control elements 1

Mode selector switch 1
Show all 300 specifications ↓ Show less ↑290 more values in Identification, Supply voltage, Input current, Power, Power loss, Storage, CPU processing times, CPU-blocks, Counters, timers and their retentivity, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Interfaces, 1. Interface, 2. Interface, Interface types, Protocols, S7 message functions, Test commissioning functions, Interrupts/diagnostics/status information, Supported technology objects, Security, Ambient conditions, Configuration, Dimensions, Version Classification, Logistics.

Identification 10

Part number 6ES7513-2PM03-0AB0
Type designation CPU 1513pro-2 PN
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4047623414216
ETIM class EC001603
eCl@ss 27242607

Supply voltage 5

Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering: Mains/voltage failure stored energy time 5 ms

Input current 4

Current consumption (rated value) 0.22 A
Current consumption, max. 0.35 A
Inrush current, max. 0.63 A; Rated value
I2t 0.3 A2·s

Power 1

Infeed power to the backplane bus 2.275 W

Power loss 1

Power loss, typ. 3.3 W

Storage 6

Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory: integrated (for program) 600 kbyte
Work memory: integrated (for data) 2.5 Mbyte
Load memory: Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup: maintenance-free Yes

CPU processing times 4

for bit operations, typ. 6 ns
for word operations, typ. 7 ns
for fixed point arithmetic, typ. 9 ns
for floating point arithmetic, typ. 37 ns

CPU-blocks 21

Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
DB: Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
DB: Size, max. 2.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB: Number range 0 ... 65 535
FB: Size, max. 600 kbyte
FC: Number range 0 ... 65 535
FC: Size, max. 600 kbyte
OB: Size, max. 600 kbyte
OB: Number of free cycle OBs 100
OB: Number of time alarm OBs 20
OB: Number of delay alarm OBs 20
OB: Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs
OB: Number of process alarm OBs 50
OB: Number of DPV1 alarm OBs 3
OB: Number of isochronous mode OBs 1
OB: Number of technology synchronous alarm OBs 2
OB: Number of startup OBs 100
OB: Number of asynchronous error OBs 4
OB: Number of synchronous error OBs 2
OB: Number of diagnostic alarm OBs 1
Nesting depth: per priority class 24

Counters, timers and their retentivity 8

S7 counter: Number Retentivity 2 048
S7 counter: adjustable Yes
IEC counter: Number Retentivity Any (only limited by the main memory)
IEC counter: adjustable Yes
S7 timer: Number Retentivity 2 048
S7 timer: adjustable Yes
IEC timer: Number Retentivity Any (only limited by the main memory)
IEC timer: adjustable Yes

Data areas and their retentivity 6

Retentive data area (incl. timers, counters, flags), max. 256 kbyte; in total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 216 KB
Flag: Size, max. 16 kbyte
Flag: Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks: Retentivity adjustable Yes
Data blocks: Retentivity preset No
Local data: per priority class, max. 64 kbyte; max. 16 KB per block

Address area 5

Number of IO modules 2 048; max. number of modules / submodules
I/O address area: Inputs 32 kbyte; All inputs are in the process image
I/O address area: Outputs per integrated IO subsystem 32 kbyte; All outputs are in the process image
I/O address area: Inputs (volume) 8 kbyte
I/O address area: Outputs (volume) 8 kbyte

Hardware configuration 5

Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of IO Controllers: Integrated 2
Number of IO Controllers: via CM 0
Rack: Modules per rack, max. 16; Expansion width max. 1.2 m
Rack: Number of lines, max. 1

Time of day 8

Clock: Type Hardware clock
Clock: Backup time 6 wk; At 40 °C ambient temperature, typically
Clock: Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter: Number 16
Clock synchronization: supported Yes
Clock synchronization: in AS, master Yes
Clock synchronization: in AS, device Yes
Clock synchronization: on Ethernet via NTP Yes

Interfaces 2

Number of PROFINET interfaces 2
Number of PROFIBUS interfaces 0

1. Interface 39

Interface types: RJ 45 (Ethernet) Yes; X1 P3
Interface types: Number of ports 3; 2x M12 + 1x RJ45
Interface types: integrated switch Yes
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO Device Yes
Protocols: SIMATIC communication Yes
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
Protocols: Media redundancy Yes
PROFINET IO Controller Services: Isochronous mode Yes
PROFINET IO Controller Services: Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
PROFINET IO Controller Services: IRT Yes
PROFINET IO Controller Services: Dynamic Frame Packing (DFP) Yes
PROFINET IO Controller Services: PROFIenergy Yes; per user program
PROFINET IO Controller Services: Prioritized startup Yes; Max. 32 PROFINET devices
PROFINET IO Controller Services: Number of connectable IO Devices, max. 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
PROFINET IO Controller Services: Of which IO devices with IRT, max. 64
PROFINET IO Controller Services: of which in line, max. 128
PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
PROFINET IO Controller Services: Number of IO Devices per tool, max. 8
PROFINET IO Controller Services: Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
PROFINET IO Controller Services: PROFINET Security Class Update time for IRT 1
PROFINET IO Controller Services: for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
PROFINET IO Controller Services: for send cycle of 500 µs 500 µs to 8 ms
PROFINET IO Controller Services: for send cycle of 1 ms 1 ms to 16 ms
PROFINET IO Controller Services: for send cycle of 2 ms 2 ms to 32 ms
PROFINET IO Controller Services: for send cycle of 4 ms 4 ms to 64 ms
PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
PROFINET IO Device Services: Isochronous mode No
PROFINET IO Device Services: IRT Yes
PROFINET IO Device Services: Dynamic Frame Packing (DFP) No
PROFINET IO Device Services: PROFIenergy Yes; per user program
PROFINET IO Device Services: Prioritized startup Yes
PROFINET IO Device Services: Shared device Yes
PROFINET IO Device Services: Number of IO Controllers with shared device, max. 4
PROFINET IO Device Services: activation/deactivation of I-devices Yes; per user program
PROFINET IO Device Services: Asset management record Yes; per user program
PROFINET IO Device Services: PROFINET Security Class SNMP Configuration and DCP Read Only

2. Interface 34

Interface types: RJ 45 (Ethernet) No
Interface types: Number of ports 1; 1x M12
Interface types: integrated switch No
Protocols: IP protocol Yes; IPv4
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO Device Yes
Protocols: SIMATIC communication Yes
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
Protocols: Media redundancy No
PROFINET IO Controller Services: Isochronous mode No
PROFINET IO Controller Services: Direct data exchange No
PROFINET IO Controller Services: IRT No
PROFINET IO Controller Services: Dynamic Frame Packing (DFP) No
PROFINET IO Controller Services: PROFIenergy Yes; per user program
PROFINET IO Controller Services: Prioritized startup No
PROFINET IO Controller Services: Number of connectable IO Devices, max. 32; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
PROFINET IO Controller Services: of which in line, max. 32
PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
PROFINET IO Controller Services: IO Devices changing during operation (partner ports), supported Yes
PROFINET IO Controller Services: Number of IO Devices per tool, max. 8
PROFINET IO Controller Services: Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
PROFINET IO Controller Services: PROFINET Security Class Update time for RT 1
PROFINET IO Controller Services: for send cycle of 1 ms 1 ms to 512 ms
PROFINET IO Device Services: Isochronous mode No
PROFINET IO Device Services: IRT No
PROFINET IO Device Services: Dynamic Frame Packing (DFP) No
PROFINET IO Device Services: PROFIenergy Yes; per user program
PROFINET IO Device Services: Prioritized startup No
PROFINET IO Device Services: Shared device Yes
PROFINET IO Device Services: Number of IO Controllers with shared device, max. 4
PROFINET IO Device Services: activation/deactivation of I-devices Yes; per user program
PROFINET IO Device Services: Asset management record Yes; per user program
PROFINET IO Device Services: PROFINET Security Class SNMP Configuration and DCP Read Only

Interface types 4

RJ 45 (Ethernet): 100 Mbps Yes
RJ 45 (Ethernet): Autonegotiation Yes
RJ 45 (Ethernet): Autocrossing Yes
RJ 45 (Ethernet): Industrial Ethernet status LED Yes

Protocols 45

PROFIsafe No
Number of connections: Number of connections, max. 128; Via integrated interfaces of the CPU
Number of connections: Number of connections reserved for ES/HMI/web 10
Number of connections: Number of connections via integrated interfaces 128
Number of connections: Number of S7 routing paths 16
Redundancy mode: PROFINET system redundancy (S2) No
Redundancy mode: PROFINET system redundancy (R1) No
Redundancy mode: H-Sync forwarding Media redundancy Yes
Redundancy mode: Media redundancy Yes; only via 1st interface (X1)
Redundancy mode: MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
Redundancy mode: MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
Redundancy mode: MRPD Yes; Requirement: IRT
Redundancy mode: Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
Redundancy mode: Number of stations in the ring, max. 50
SIMATIC communication: PG/OP communication Yes; encryption with TLS V1.3 pre-selected
SIMATIC communication: S7 routing Yes
SIMATIC communication: S7 communication, as server Yes
SIMATIC communication: S7 communication, as client Yes
SIMATIC communication: User data per job, max. See online help (S7 communication, user data size)
Open IE communication: TCP/IP Yes
Open IE communication: Data length, max. 64 kbyte
Open IE communication: several passive connections per port, supported Yes
Open IE communication: ISO-on-TCP (RFC1006) Yes
Open IE communication: UDP Yes
Open IE communication: UDP multicast Yes; max. 78 multicast circuits
Open IE communication: DHCP Yes
Open IE communication: DNS Yes
Open IE communication: SNMP Yes
Open IE communication: DCP Yes
Open IE communication: LLDP Yes
Open IE communication: Encryption Yes; Optional
Web server: HTTP Yes; Standard and user pages
Web server: HTTPS Yes; Standard and user pages
web API: Number of sessions, max. 50
web API: number of simultaneous HTTP calls, max. 4
web API: HTTP request body, max. 131 072 byte
OPC UA: Runtime license required Yes; "Small" license required
OPC UA: OPC UA Client Yes; Data access (read, write), method call
OPC UA: Application authentication Yes
OPC UA: Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
OPC UA: User authentication "anonymous" or by user name & password
OPC UA: Number of connections, max. 4
OPC UA: Number of nodes of the client interfaces, recommended max. 1 000
Number of elements for one call of 300 OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.: Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20
Further protocols: MODBUS Yes; MODBUS TCP

S7 message functions 8

Number of login stations for message functions, max. 32
number of subscriptions, max. 250
number of tags/attributes for subscriptions, max. 2 000
Program alarms Yes
Number of configurable program messages, max. 5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max. 5 000
Number of simultaneously active program alarms: Number of program alarms 600
Number of simultaneously active program alarms: Number of alarms for system diagnostics 100

Test commissioning functions 17

Joint commission (Team Engineering) Yes; Parallel online access possible for up to 5 engineering systems
Status block Yes; Up to 8 simultaneously (in total across all ES clients)
Single step Yes
Number of breakpoints 8
Profiling Yes
Status/control: Status/control variable Yes
Status/control: Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.: of which status variables, max. 200; per job
Number of variables, max.: of which control variables, max. 200; per job
Forcing: Forcing Yes
Forcing: Forcing, variables Peripheral inputs/outputs
Forcing: Number of variables, max. 200
Diagnostic buffer: present Yes
Diagnostic buffer: Number of entries, max. 1 000
Diagnostic buffer: of which powerfail-proof 500
Traces: Number of configurable Traces 4
Traces: Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information 5

Diagnostics indication LED: RUN/STOP LED Yes
Diagnostics indication LED: ERROR LED Yes
Diagnostics indication LED: MAINT LED Yes
Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) Yes; green "24 V DC" LED
Diagnostics indication LED: Connection display LINK TX/RX Yes

Supported technology objects 14

Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects 1 120
Required Motion Control resources: per speed-controlled axis 40
Required Motion Control resources: per positioning axis 80
Required Motion Control resources: per synchronous axis 160
Required Motion Control resources: per external encoder 80
Required Motion Control resources: per output cam 20
Required Motion Control resources: per cam track 160
Required Motion Control resources: per probe 40
Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) 11
Controller: PID_Compact Yes; Universal PID controller with integrated optimization
Controller: PID_3Step Yes; PID controller with integrated optimization for valves
Controller: PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring: High-speed counter Yes

Security 4

PROFINET Security Class 1
signed firmware update Yes
Secure Boot Yes
securely removing data Yes

Ambient conditions 5

Ambient temperature during operation: horizontal installation, min. -25 °C
Ambient temperature during operation: vertical installation, min. -25 °C
Ambient temperature during storage/transportation: min. -40 °C
Ambient temperature during storage/transportation: max. 70 °C
Altitude during operation relating to sea level: Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual

Configuration 19

Programming Programming language: LAD Yes
Programming Programming language: FBD Yes
Programming Programming language: STL Yes
Programming Programming language: SCL Yes
Programming Programming language: GRAPH Yes
Know-how protection: User program protection/password protection Yes
Know-how protection: Copy protection Yes
Know-how protection: Block protection Yes
Access protection: protection of confidential configuration data Yes
Access protection: Protection level: Write protection Yes
Access protection: Protection level: Read/write protection Yes
Access protection: Protection level: Write protection for Failsafe No
Access protection: Protection level: Complete protection Yes
Access protection: User administration Yes; device-wide and centralized
Access protection: Number of users 100
Access protection: Number of groups 100
Access protection: Number of roles 50
Cycle time monitoring: lower limit adjustable minimum cycle time
Cycle time monitoring: upper limit adjustable maximum cycle time

Dimensions 2

Width 135 mm
Height 130 mm

Version Classification 2

eClass 16 27-24-26-07
ETIM 10 EC001603

Logistics 6

Net weight 0.6 kg
Country of origin DE
Shipping weight 1.1 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7513-2PM03-0AB0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • GDS support (certificate management)
Quick answers

Questions about the CPU 1513pro-2 PN

What is the rated current of CPU 1513pro-2 PN?

The rated current of CPU 1513pro-2 PN is 0.22 A.

Which supply voltage is CPU 1513pro-2 PN rated for?

The rated operational voltage of CPU 1513pro-2 PN is 24 V DC.

What is the HS code of CPU 1513pro-2 PN for customs?

The tariff (HS) code on file for CPU 1513pro-2 PN is 85371091.

What is the EAN of CPU 1513pro-2 PN?

The EAN (GTIN) of CPU 1513pro-2 PN is 4047623414216.

Where does CPU 1513pro-2 PN ship from, and how fast?

CPU 1513pro-2 PN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC S7-1500

Brand
Siemens
Series
SIMATIC S7-1500
$2,265.62 On request
Get a Quote
Quote

Get a Quote

CPU 1513pro-2 PN

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7513-2PM03-0AB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart