Part number
6ES7512-1SM03-0AB0
Model no
CPU 1512SP F-1 PN
$1,765.25 Low stock Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye
SIMATIC S7-1500

Siemens 6ES7512-1SM03-0AB0 SIMATIC S7-1500 CPU 1512SP F-1 PN Fail-safe Programmable Logic Controller

SIMATIC CPU 1512SP F-1 PN, fail-safe ET 200SP CPU, 600KB program / 2MB data, PROFINET IRT 3-port switch, SIL 3/PL e.

Rated current
0.48 A
Rated operational voltage
24 V AC
Communication
PROFINET IO Controller/Device, IRT, integrated 3-port switch
EAN
4047623412748
Description

About the CPU 1512SP F-1 PN

The Siemens 6ES7512-1SM03-0AB0 is a SIMATIC CPU 1512SP F-1 PN, a fail-safe central processing unit for ET 200SP stations with 600 KB program memory, 2 MB data memory, and a PROFINET IRT interface with an integrated 3-port switch. It supports safety programs up to SIL 3 / PL e alongside standard control logic in one CPU.

Certifications & Standards

    Selection Notes

    The F-1 designation and included server module (6ES7193-6PA00-0AA0) support fail-safe programs up to SIL 3 / PL e running alongside standard logic in the same CPU cycle, avoiding a separate safety controller. The integrated 3-port PROFINET switch with IRT lets ET 200SP racks daisy-chain without external switches, and the 600 KB / 2 MB memory split is sized for machine-level safety-plus-standard applications rather than plant-wide control. A SIMATIC Memory Card is required and not included — order separately based on program size.

    Applications

    Used as the safety-rated head module of ET 200SP distributed I/O stations on machine tools, packaging lines, and material handling systems where a single CPU must run both standard PLC logic and SIL 3 safety functions over PROFINET.

    Specification

    Full specification

    302 values · Last verified 01 Nov 2026

    General information 9

    Product type designation CPU 1512SP F-1 PN
    HW functional status FS04
    Firmware version V4.0
    FW update possible Yes
    Product function: I&M data Yes; I&M0 to I&M3
    Product function: Module swapping during operation (hot swapping) Yes; Multi-hot swapping
    Product function: Isochronous mode Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs
    Product function: SysLog Yes
    Engineering with: STEP 7 TIA Portal configurable/integrated from version V20 (FW V4.0) / V18 (FW V3.0) or higher; configurable with older TIA Portal versions as 6ES7 512-1SK01-0AB0

    Configuration control 1

    via dataset Yes

    Control elements 1

    Mode selector switch 1
    Show all 302 specifications ↓ Show less ↑291 more values in Identification, Supply voltage, Input current, Power, Power loss, Storage, CPU processing times, CPU-blocks, Counters, timers and their retentivity, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Interfaces, 1. Interface, 2. Interface, Interface types, Protocols, S7 message functions, Test commissioning functions, Interrupts/diagnostics/status information, Supported technology objects, Standards, approvals, certificates, Security, Ambient conditions, Configuration, Dimensions, Weights, General Product Approval, Logistics.

    Identification 10

    Part number 6ES7512-1SM03-0AB0
    Type designation CPU 1512SP F-1 PN
    Brand Siemens
    Condition New, factory sealed
    Source Siemens and its authorised distributors
    Warranty Manufacturer warranty
    Lifecycle status Active, in production
    EAN 4047623412748
    ETIM class EC001603
    eCl@ss 27242607

    Supply voltage 5

    Rated value (DC) 24 V
    permissible range, lower limit (DC) 19.2 V
    permissible range, upper limit (DC) 28.8 V
    Reverse polarity protection Yes
    Mains buffering: Mains/voltage failure stored energy time 10 ms

    Input current 4

    Current consumption (rated value) 0.48 A
    Current consumption, max. 0.7 A
    Inrush current, max. 1.34 A; Rated value
    I2t 0.3 A2·s

    Power 1

    Infeed power to the backplane bus 8.05 W

    Power loss 1

    Power loss, typ. 3.5 W

    Storage 6

    Number of slots for SIMATIC memory card 1
    SIMATIC memory card required Yes
    Work memory: integrated (for program) 600 kbyte
    Work memory: integrated (for data) 2 Mbyte
    Load memory: Plug-in (SIMATIC Memory Card), max. 32 Gbyte
    Backup: maintenance-free Yes

    CPU processing times 4

    for bit operations, typ. 6 ns
    for word operations, typ. 7 ns
    for fixed point arithmetic, typ. 9 ns
    for floating point arithmetic, typ. 37 ns

    CPU-blocks 21

    Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
    DB: Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    DB: Size, max. 2 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB: Number range 0 ... 65 535
    FB: Size, max. 600 kbyte
    FC: Number range 0 ... 65 535
    FC: Size, max. 600 kbyte
    OB: Size, max. 600 kbyte
    OB: Number of free cycle OBs 100
    OB: Number of time alarm OBs 20
    OB: Number of delay alarm OBs 20
    OB: Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs
    OB: Number of process alarm OBs 50
    OB: Number of DPV1 alarm OBs 3
    OB: Number of isochronous mode OBs 1
    OB: Number of technology synchronous alarm OBs 2
    OB: Number of startup OBs 100
    OB: Number of asynchronous error OBs 4
    OB: Number of synchronous error OBs 2
    OB: Number of diagnostic alarm OBs 1
    Nesting depth: per priority class 24; Up to 8 possible for F-blocks

    Counters, timers and their retentivity 8

    S7 counter: Number Retentivity 2 048
    S7 counter: adjustable Yes
    IEC counter: Number Retentivity Any (only limited by the main memory)
    IEC counter: adjustable Yes
    S7 timer: Number Retentivity 2 048
    S7 timer: adjustable Yes
    IEC timer: Number Retentivity Any (only limited by the main memory)
    IEC timer: adjustable Yes

    Data areas and their retentivity 6

    Retentive data area (incl. timers, counters, flags), max. 256 kbyte; in total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 216 KB
    Flag: Size, max. 16 kbyte
    Flag: Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks: Retentivity adjustable Yes
    Data blocks: Retentivity preset No
    Local data: per priority class, max. 64 kbyte; max. 16 KB per block

    Address area 9

    Number of IO modules 2 048; max. number of modules / submodules
    I/O address area: Inputs 32 kbyte; All inputs are in the process image
    I/O address area: Outputs per integrated IO subsystem 32 kbyte; All outputs are in the process image
    I/O address area: Inputs (volume) 8 kbyte
    I/O address area: Outputs (volume) per CM/CP 8 kbyte
    I/O address area: Outputs (volume) 8 kbyte
    Subprocess images: Number of subprocess images, max. 32
    Address space per module: Address space per module, max. 288 byte; For input and output data respectively
    Address space per station: Address space per station, max. 2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules

    Hardware configuration 9

    Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of DP masters: via CM 1
    Number of IO Controllers: Integrated 1
    Number of IO Controllers: via CM 0
    Rack: Modules per rack, max. 82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
    Rack: Quantity of operable ET 200SP modules, max. 64
    Rack: Quantity of operable ET 200AL modules, max. 16
    Rack: Number of lines, max. 1
    PtP CM: Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots

    Time of day 10

    Clock: Type Hardware clock
    Clock: Backup time 6 wk; At 40 °C ambient temperature, typically
    Clock: Deviation per day, max. 10 s; Typ.: 2 s
    Operating hours counter: Number 16
    Clock synchronization: supported Yes
    Clock synchronization: to DP, master Yes; Via CM DP module
    Clock synchronization: on DP, device Yes; Via CM DP module
    Clock synchronization: in AS, master Yes
    Clock synchronization: in AS, device Yes
    Clock synchronization: on Ethernet via NTP Yes

    Interfaces 3

    Number of PROFINET interfaces 1
    Number of PROFIBUS interfaces 1; Via CM DP module
    Optical interface Yes; Via SIMATIC BusAdapter

    1. Interface 40

    Interface types: RJ 45 (Ethernet) Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
    Interface types: Number of ports 3; 1. integr. + 2. via BusAdapter
    Interface types: integrated switch Yes
    Interface types: BusAdapter (PROFINET) Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC
    Protocols: IP protocol Yes; IPv4
    Protocols: PROFINET IO Controller Yes
    Protocols: PROFINET IO Device Yes
    Protocols: SIMATIC communication Yes
    Protocols: Open IE communication Yes; Optionally also encrypted
    Protocols: Web server Yes
    Protocols: Media redundancy Yes
    PROFINET IO Controller Services: Isochronous mode Yes
    PROFINET IO Controller Services: Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
    PROFINET IO Controller Services: IRT Yes
    PROFINET IO Controller Services: Dynamic Frame Packing (DFP) Yes
    PROFINET IO Controller Services: PROFIenergy Yes; per user program
    PROFINET IO Controller Services: Prioritized startup Yes; Max. 32 PROFINET devices
    PROFINET IO Controller Services: Number of connectable IO Devices, max. 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    PROFINET IO Controller Services: Of which IO devices with IRT, max. 64
    PROFINET IO Controller Services: of which in line, max. 128
    PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
    PROFINET IO Controller Services: Number of IO Devices per tool, max. 8
    PROFINET IO Controller Services: Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    PROFINET IO Controller Services: PROFINET Security Class Update time for IRT 1
    PROFINET IO Controller Services: for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
    PROFINET IO Controller Services: for send cycle of 500 µs 500 µs to 8 ms
    PROFINET IO Controller Services: for send cycle of 1 ms 1 ms to 16 ms
    PROFINET IO Controller Services: for send cycle of 2 ms 2 ms to 32 ms
    PROFINET IO Controller Services: for send cycle of 4 ms 4 ms to 64 ms
    PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    PROFINET IO Device Services: Isochronous mode No
    PROFINET IO Device Services: IRT Yes
    PROFINET IO Device Services: Dynamic Frame Packing (DFP) No
    PROFINET IO Device Services: PROFIenergy Yes; per user program
    PROFINET IO Device Services: Prioritized startup Yes
    PROFINET IO Device Services: Shared device Yes
    PROFINET IO Device Services: Number of IO Controllers with shared device, max. 4
    PROFINET IO Device Services: activation/deactivation of I-devices Yes; per user program
    PROFINET IO Device Services: Asset management record Yes; per user program
    PROFINET IO Device Services: PROFINET Security Class SNMP Configuration and DCP Read Only

    2. Interface 10

    Interface types: RS 485 Yes; Via CM DP module
    Interface types: Number of ports 1
    Protocols: PROFIBUS DP master Yes
    Protocols: PROFIBUS DP device Yes
    Protocols: SIMATIC communication Yes
    PROFIBUS DP master: Number of connections, max. 48; Of which 4 each reserved for ES and HMI
    PROFIBUS DP master: max. number of DP devices Services 125; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    PROFIBUS DP master: Equidistance No
    PROFIBUS DP master: Isochronous mode No
    PROFIBUS DP master: activation/deactivation of DP devices Yes

    Interface types 5

    RJ 45 (Ethernet): 100 Mbps Yes
    RJ 45 (Ethernet): Autonegotiation Yes
    RJ 45 (Ethernet): Autocrossing Yes
    RJ 45 (Ethernet): Industrial Ethernet status LED Yes
    RS 485: Transmission rate, max. 12 Mbit/s

    Protocols 47

    PROFIsafe Yes; V2.4 / V2.6
    Number of connections: Number of connections, max. 128; via integrated interfaces of the CPU and connected CPs / CMs
    Number of connections: Number of connections reserved for ES/HMI/web 10
    Number of connections: Number of connections via integrated interfaces 88
    Number of connections: Number of connections per CP/CM 32
    Number of connections: Number of S7 routing paths 16
    Redundancy mode: PROFINET system redundancy (S2) No
    Redundancy mode: PROFINET system redundancy (R1) No
    Redundancy mode: H-Sync forwarding Media redundancy Yes
    Redundancy mode: Media redundancy Yes; only via BusAdapter
    Redundancy mode: MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
    Redundancy mode: MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
    Redundancy mode: MRPD Yes; Requirement: IRT
    Redundancy mode: Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
    Redundancy mode: Number of stations in the ring, max. 50
    SIMATIC communication: PG/OP communication Yes; encryption with TLS V1.3 pre-selected
    SIMATIC communication: S7 routing Yes
    SIMATIC communication: Data record routing Yes
    SIMATIC communication: S7 communication, as server Yes
    SIMATIC communication: S7 communication, as client Yes
    SIMATIC communication: User data per job, max. See online help (S7 communication, user data size)
    Open IE communication: TCP/IP Yes
    Open IE communication: Data length, max. 64 kbyte
    Open IE communication: several passive connections per port, supported Yes
    Open IE communication: ISO-on-TCP (RFC1006) Yes
    Open IE communication: UDP Yes
    Open IE communication: UDP multicast Yes; max. 78 multicast circuits
    Open IE communication: DHCP Yes
    Open IE communication: DNS Yes
    Open IE communication: SNMP Yes
    Open IE communication: DCP Yes
    Open IE communication: LLDP Yes
    Open IE communication: Encryption Yes; Optional
    Web server: HTTP Yes; Standard and user pages
    Web server: HTTPS Yes; Standard and user pages
    web API: Number of sessions, max. 50
    web API: number of simultaneous HTTP calls, max. 4
    web API: HTTP request body, max. 131 072 byte
    OPC UA: Runtime license required Yes; "Small" license required
    OPC UA: OPC UA Client Yes; Data Access (registered Read/Write), Method Call
    OPC UA: Application authentication Yes
    OPC UA: Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    OPC UA: User authentication "anonymous" or by user name & password
    OPC UA: Number of connections, max. 4
    OPC UA: Number of nodes of the client interfaces, recommended max. 1 000
    Number of elements for one call of 300 OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.: Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20
    Further protocols: MODBUS Yes; MODBUS TCP

    S7 message functions 8

    Number of login stations for message functions, max. 32
    number of subscriptions, max. 250
    number of tags/attributes for subscriptions, max. 2 000
    Program alarms Yes
    Number of configurable program messages, max. 5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
    Number of loadable program messages in RUN, max. 5 000
    Number of simultaneously active program alarms: Number of program alarms 600
    Number of simultaneously active program alarms: Number of alarms for system diagnostics 100

    Test commissioning functions 17

    Joint commission (Team Engineering) Yes; Parallel online access possible for up to 5 engineering systems
    Status block Yes; Up to 8 simultaneously (in total across all ES clients)
    Single step Yes
    Number of breakpoints 8
    Profiling Yes
    Status/control: Status/control variable Yes; without fail-safe
    Status/control: Variables inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
    Number of variables, max.: of which status variables, max. 200; per job
    Number of variables, max.: of which control variables, max. 200; per job
    Forcing: Forcing Yes; without fail-safe
    Forcing: Forcing, variables peripheral inputs/outputs (without fail-safe)
    Forcing: Number of variables, max. 200
    Diagnostic buffer: present Yes
    Diagnostic buffer: Number of entries, max. 1 000
    Diagnostic buffer: of which powerfail-proof 500
    Traces: Number of configurable Traces 4
    Traces: Memory size per trace, max. 512 kbyte

    Interrupts/diagnostics/status information 5

    Diagnostics indication LED: RUN/STOP LED Yes
    Diagnostics indication LED: ERROR LED Yes
    Diagnostics indication LED: MAINT LED Yes
    Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) Yes
    Diagnostics indication LED: Connection display LINK TX/RX Yes

    Supported technology objects 14

    Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
    Number of available Motion Control resources for technology objects 1 120
    Required Motion Control resources: per speed-controlled axis 40
    Required Motion Control resources: per positioning axis 80
    Required Motion Control resources: per synchronous axis 160
    Required Motion Control resources: per external encoder 80
    Required Motion Control resources: per output cam 20
    Required Motion Control resources: per cam track 160
    Required Motion Control resources: per probe 40
    Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) 11
    Controller: PID_Compact Yes; Universal PID controller with integrated optimization
    Controller: PID_3Step Yes; PID controller with integrated optimization for valves
    Controller: PID-Temp Yes; PID controller with integrated optimization for temperature
    Counting and measuring: High-speed counter Yes

    Standards, approvals, certificates 9

    Ecological footprint: environmental product declaration Global warming potential Yes
    Ecological footprint: global warming potential, (total) [CO2 eq] 83.2 kg
    Ecological footprint: global warming potential, (during production) [CO2 eq] 22.3 kg
    Ecological footprint: global warming potential, (during operation) [CO2 eq] 61.8 kg
    Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] -0.949 kg
    Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 PLe
    Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) SIL 3
    Highest safety class achievable in safety mode: Low demand mode: PFDavg in accordance with SIL3 < 2.00E-05
    Highest safety class achievable in safety mode: High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09

    Security 4

    PROFINET Security Class 1
    signed firmware update Yes
    Secure Boot Yes
    securely removing data Yes

    Ambient conditions 3

    Ambient temperature during operation: horizontal installation, min. -30 °C; No condensation
    Ambient temperature during operation: vertical installation, min. -30 °C; No condensation
    Altitude during operation relating to sea level: Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual

    Configuration 20

    Programming Programming language: LAD Yes; incl. failsafe
    Programming Programming language: FBD Yes; incl. failsafe
    Programming Programming language: STL Yes
    Programming Programming language: SCL Yes
    Programming Programming language: CFC No
    Programming Programming language: GRAPH Yes
    Know-how protection: User program protection/password protection Yes
    Know-how protection: Copy protection Yes
    Know-how protection: Block protection Yes
    Access protection: protection of confidential configuration data Yes
    Access protection: Protection level: Write protection Yes
    Access protection: Protection level: Read/write protection Yes
    Access protection: Protection level: Write protection for Failsafe Yes
    Access protection: Protection level: Complete protection Yes
    Access protection: User administration Yes; device-wide and centralized
    Access protection: Number of users 100
    Access protection: Number of groups 100
    Access protection: Number of roles 50
    Cycle time monitoring: lower limit adjustable minimum cycle time
    Cycle time monitoring: upper limit adjustable maximum cycle time

    Dimensions 3

    Width 100 mm
    Height 117 mm
    Depth 75 mm

    Weights 1

    Weight, approx. 265 g

    General Product Approval 2

    Miscellaneous Manufacturer Declara- Miscellaneous tion
    TUEV China RoHS Manufacturer Declara- tion

    Logistics 6

    Net weight 0.339 kg
    Country of origin DE
    Shipping weight 0.839 kg
    Ships from Türkiye
    Dispatch 18 Nov
    Stock Low stock

    Source: manufacturer data · Last verified: 01 Nov 2026

    Documents

    Documents for 6ES7512-1SM03-0AB0

    No documents are on file for this part yet.

    Ask us for the datasheet
    Certifications

    Certifications and standards

    • GDS support (certificate management)
    Quick answers

    Questions about the CPU 1512SP F-1 PN

    What is the rated current of CPU 1512SP F-1 PN?

    The rated current of CPU 1512SP F-1 PN is 0.48 A.

    Which supply voltage is CPU 1512SP F-1 PN rated for?

    The rated operational voltage of CPU 1512SP F-1 PN is 24 V AC.

    What is the HS code of CPU 1512SP F-1 PN for customs?

    The tariff (HS) code on file for CPU 1512SP F-1 PN is 85371091.

    What is the EAN of CPU 1512SP F-1 PN?

    The EAN (GTIN) of CPU 1512SP F-1 PN is 4047623412748.

    Where does CPU 1512SP F-1 PN ship from, and how fast?

    CPU 1512SP F-1 PN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

    Guides

    Guides for PLC & controllers

    All guides for PLC & controllers
    Reviews

    Customer reviews

    Series

    Siemens SIMATIC S7-1500

    Brand
    Siemens
    Series
    SIMATIC S7-1500
    $1,765.25 Low stock · 18 Nov
    Quote

    Get a Quote

    CPU 1512SP F-1 PN

    Genuine parts

    Genuine, factory-sealed parts

    Siemens · 6ES7512-1SM03-0AB0

    Every part on Stoklink is new, unused and made by the manufacturer named on the page.

    Condition
    New and unused, in the manufacturer's factory-sealed packaging.
    Sourced from
    Siemens and its authorised distributors.
    Warranty
    The manufacturer's warranty applies.
    If a part is not genuine
    We refund the full amount.

    Added to cart Could not add to cart

    View cart