How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
The Siemens 6ES7512-1DM03-0AB0 is a SIMATIC S7-1500 CPU 1512SP-1 PN for the ET 200SP distributed I/O system, with 400 KB of integrated work memory for program and 2 MB for data. Its PROFINET interface has an integrated 3-port switch with IRT support and 6 ns bit-instruction processing. The CPU requires a SIMATIC Memory Card and a BusAdapter for ports 1 and 2, both ordered separately.
400 KB of program memory and 2 MB of data memory position this CPU above the base S7-1500 entry points for machine control programs with multiple technology objects or larger recipe/data-logging structures. The integrated 3-port PROFINET switch with IRT support removes the need for an external switch when daisy-chaining ET 200SP stations that require isochronous drive synchronization; projects without IRT requirements can use a lower-cost CPU in the same rack format. Because the SIMATIC Memory Card and BusAdapter are ordered separately, confirm both are in the same cart before commissioning.
Machine and process controllers built on the ET 200SP distributed I/O platform, including applications needing PROFINET IRT for coordinated axis motion or tight cycle-time synchronization across multiple stations.
| Product type designation | CPU 1512SP-1 PN |
|---|---|
| HW functional status | FS06 |
| Firmware version | V4.2 |
| FW update possible | Yes |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| Product function: Isochronous mode | Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs |
| Product function: SysLog | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V21.1 (FW V4.2) / V18 (FW V3.0) or higher; configurable with older TIA Portal versions as 6ES7512-1DK01-0AB0 |
| via dataset | Yes |
|---|
| Mode selector switch | 1 |
|---|
| Part number | 6ES7512-1DM03-0AB0 |
|---|---|
| Type designation | CPU 1512SP-1 PN |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623412731 |
| ETIM class | EC001603 |
| eCl@ss | 27242607 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 10 ms |
| Current consumption (rated value) | 0.48 A |
|---|---|
| Current consumption, max. | 0.7 A |
| Inrush current, max. | 1.34 A; Rated value |
| I2t | 0.3 A2·s |
| Infeed power to the backplane bus | 8.05 W |
|---|
| Power loss, typ. | 3.4 W |
|---|
| Multi-core processor: number of processor cores | 2 |
|---|---|
| Multi-core processor: number of processor cores for user program | 1 |
| Number of slots for SIMATIC memory card | 1 |
|---|---|
| SIMATIC memory card required | Yes |
| Work memory: integrated (for program) | 400 kbyte |
| Work memory: integrated (for data) | 2 Mbyte |
| Load memory: Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
| Backup: maintenance-free | Yes |
| for bit operations, typ. | 6 ns |
|---|---|
| for word operations, typ. | 7 ns |
| for fixed point arithmetic, typ. | 9 ns |
| for floating point arithmetic, typ. | 37 ns |
| Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
|---|---|
| DB: Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 |
| DB: Size, max. | 1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
| FB: Number range | 0 ... 65 535 |
| FB: Size, max. | 400 kbyte |
| FC: Number range | 0 ... 65 535 |
| FC: Size, max. | 400 kbyte |
| OB: Size, max. | 400 kbyte |
| OB: Number of free cycle OBs | 256 |
| OB: Number of time alarm OBs | 20 |
| OB: Number of delay alarm OBs | 20 |
| OB: Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 250 µs |
| OB: Number of process alarm OBs | 50 |
| OB: Number of DPV1 alarm OBs | 3 |
| OB: Number of isochronous mode OBs | 1 |
| OB: Number of startup OBs | 256 |
| OB: Number of asynchronous error OBs | 4 |
| OB: Number of synchronous error OBs | 2 |
| OB: Number of diagnostic alarm OBs | 1 |
| Nesting depth: per priority class | 24 |
| S7 counter: Number Retentivity | 2 048 |
|---|---|
| S7 counter: adjustable | Yes |
| IEC counter: Number Retentivity | Any (only limited by the main memory) |
| IEC counter: adjustable | Yes |
| S7 timer: Number Retentivity | 2 048 |
| S7 timer: adjustable | Yes |
| IEC timer: Number Retentivity | Any (only limited by the main memory) |
| IEC timer: can be set | Yes |
| Retentive data area (incl. timers, counters, flags), max. | 216 kbyte; in total; for bit memories, timers, counters, DBs, and technology data (axes) |
|---|---|
| Flag: Size, max. | 16 kbyte |
| Flag: Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks: Retentivity adjustable | Yes |
| Data blocks: Retentivity preset | No |
| Local data: per priority class, max. | 64 kbyte; max. 16 KB per block |
| Number of IO modules | 2 048; max. number of modules / submodules |
|---|---|
| I/O address area: Inputs | 32 kbyte; All inputs are in the process image |
| I/O address area: Outputs per integrated IO subsystem | 32 kbyte; All outputs are in the process image |
| I/O address area: Inputs (volume) | 8 kbyte |
| I/O address area: Outputs (volume) per CM/CP | 8 kbyte |
| I/O address area: Outputs (volume) | 8 kbyte |
| Subprocess images: Number of subprocess images, max. | 32 |
| Address space per module: Address space per module, max. | 288 byte; For input and output data respectively |
| Address space per station: Address space per station, max. | 2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules |
| Number of distributed IO systems | 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
|---|---|
| Number of DP masters: Via CM | 1 |
| Number of IO Controllers: Integrated | 1 |
| Number of IO Controllers: via CM | 0 |
| Rack: Modules per rack, max. | 82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules |
| Rack: Quantity of operable ET 200SP modules, max. | 64 |
| Rack: Quantity of operable ET 200AL modules, max. | 16 |
| Rack: Number of lines, max. | 1 |
| PtP CM: Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
| Clock: Type | Hardware clock |
|---|---|
| Clock: Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Clock: Deviation per day, max. | 10 s; Typ.: 2 s |
| Operating hours counter: Number | 64 |
| Clock synchronization: supported | Yes |
| Clock synchronization: to DP, master | Yes; Via CM DP module |
| Clock synchronization: on DP, device | Yes; Via CM DP module |
| Clock synchronization: in AS, master | Yes |
| Clock synchronization: in AS, device | Yes |
| Clock synchronization: on Ethernet via NTP | Yes |
| Number of PROFINET interfaces | 1 |
|---|---|
| Number of PROFIBUS interfaces | 1; Via CM DP module |
| Optical interface | Yes; Via SIMATIC BusAdapter |
| Interface types: RJ 45 (Ethernet) | Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45 |
|---|---|
| Interface types: Number of ports | 3; 1. integr. + 2. via BusAdapter |
| Interface types: integrated switch | Yes |
| Interface types: BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC, BA 2x LC-LD, BA LC-LD / RJ45, BA LC-LD / M12 |
| Protocols: IP protocol | Yes; IPv4/IPv6 |
| Protocols: PROFINET IO Controller | Yes |
| Protocols: PROFINET IO device | Yes |
| Protocols: SIMATIC communication | Yes |
| Protocols: Open IE communication | Yes; Optionally also encrypted |
| Protocols: Web server | Yes |
| Protocols: Media redundancy | Yes |
| PROFINET IO Controller Services: Isochronous mode | Yes |
| PROFINET IO Controller Services: Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| PROFINET IO Controller Services: IRT | Yes; max. 4 CR per Device |
| PROFINET IO Controller Services: Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Controller Services: PROFIenergy | Yes; per user program |
| PROFINET IO Controller Services: Prioritized startup | Yes; Max. 32 PROFINET devices |
| PROFINET IO Controller Services: Number of connectable IO Devices, max. | 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| PROFINET IO Controller Services: Of which IO devices with IRT, max. | 64 |
| PROFINET IO Controller Services: of which in line, max. | 128 |
| PROFINET IO Controller Services: Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| PROFINET IO Controller Services: Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller Services: Updating times Update time for IRT | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET IO Controller Services: for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive |
| PROFINET IO Controller Services: for send cycle of 500 µs | 500 µs to 8 ms |
| PROFINET IO Controller Services: for send cycle of 1 ms | 1 ms to 16 ms |
| PROFINET IO Controller Services: for send cycle of 2 ms | 2 ms to 32 ms |
| PROFINET IO Controller Services: for send cycle of 4 ms | 4 ms to 64 ms |
| PROFINET IO Controller Services: With IRT and parameterization of "odd" send cycles Update time for RT | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) |
| PROFINET IO Device Services: Isochronous mode | No |
| PROFINET IO Device Services: IRT | Yes |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | No |
| PROFINET IO Device Services: PROFIenergy | Yes; per user program |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 4 |
| PROFINET IO Device Services: activation/deactivation of I-devices | Yes; per user program |
| PROFINET IO Device Services: Asset management record | Yes; per user program |
| Interface types: RS 485 | Yes; Via CM DP module |
|---|---|
| Interface types: Number of ports | 1 |
| Protocols: PROFIBUS DP master | Yes |
| Protocols: PROFIBUS DP device | Yes |
| Protocols: SIMATIC communication | Yes |
| PROFIBUS DP master: Number of connections, max. | 48; Of which 4 each reserved for ES and HMI |
| PROFIBUS DP master: max. number of DP devices Services | 125; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| PROFIBUS DP master: Equidistance | No |
| PROFIBUS DP master: Isochronous mode | No |
| PROFIBUS DP master: activation/deactivation of DP devices | Yes |
| RJ 45 (Ethernet): 100 Mbps | Yes |
|---|---|
| RJ 45 (Ethernet): Autonegotiation | Yes |
| RJ 45 (Ethernet): Autocrossing | Yes |
| RJ 45 (Ethernet): Industrial Ethernet status LED | Yes |
| RS 485: Transmission rate, max. | 12 Mbit/s |
| PROFIsafe | No |
|---|---|
| Number of connections: Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs |
| Number of connections: Number of connections reserved for ES/HMI/web | 10 |
| Number of connections: Number of connections via integrated interfaces | 88 |
| Number of connections: Number of connections per CP/CM | 32 |
| Number of connections: Number of S7 routing paths | 16 |
| Redundancy mode: H-Sync forwarding Media redundancy | Yes |
| Redundancy mode: Media redundancy | Yes; only via BusAdapter |
| Redundancy mode: MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
| Redundancy mode: MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| Redundancy mode: MRPD | Yes; Requirement: IRT |
| Redundancy mode: Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Redundancy mode: Number of stations in the ring, max. | 50 |
| SIMATIC communication: PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| SIMATIC communication: S7 routing | Yes |
| SIMATIC communication: Data record routing | Yes |
| SIMATIC communication: S7 communication, as server | Yes |
| SIMATIC communication: S7 communication, as client | Yes |
| SIMATIC communication: User data per job, max. | See online help (S7 communication, user data size) |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: Data length, max. | 64 kbyte |
| Open IE communication: several passive connections per port, supported | Yes |
| Open IE communication: ISO-on-TCP (RFC1006) | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: UDP multicast | Yes; max. 78 multicast circuits |
| Open IE communication: DHCP | Yes; DHCPv4/DHCPv6 |
| Open IE communication: DNS | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: DCP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: Encryption | Yes; Optional |
| Web server: HTTP | Yes; Standard and user pages |
| Web server: HTTPS | Yes; Standard and user pages |
| web API: Number of sessions, max. | 50 |
| web API: number of simultaneous HTTP calls, max. | 4 |
| web API: HTTP request body, max. | 131 072 byte |
| OPC UA: Runtime license required | Yes; "Small" license required |
| OPC UA: OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| OPC UA: Application authentication | Yes |
| OPC UA: Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| OPC UA: User authentication | "anonymous" or by user name & password |
| OPC UA: Number of connections, max. | 4 |
| OPC UA: Number of nodes of the client interfaces, recommended max. | 1 000 |
| Number of elements for one call of 300 OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.: Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
| Further protocols: MODBUS | Yes; MODBUS TCP |
| Number of login stations for message functions, max. | 32 |
|---|---|
| number of subscriptions, max. | 250 |
| number of tags/attributes for subscriptions, max. | 2 000 |
| Program alarms | Yes |
| Number of configurable program messages, max. | 5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
| Number of loadable program messages in RUN, max. | 5 000 |
| Number of simultaneously active program alarms: Number of program alarms | 600 |
| Number of simultaneously active program alarms: Number of alarms for system diagnostics | 100 |
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
|---|---|
| Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
| Single step | Yes |
| Number of breakpoints | 8 |
| Profiling | Yes |
| Status/control: Status/control variable | Yes |
| Status/control: Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max.: of which status variables, max. | 200; per job |
| Number of variables, max.: of which control variables, max. | 200; per job |
| Forcing: Forcing | Yes |
| Forcing: Forcing, variables | Peripheral inputs/outputs |
| Forcing: Number of variables, max. | 200 |
| Diagnostic buffer: present | Yes |
| Diagnostic buffer: Number of entries, max. | 1 000 |
| Diagnostic buffer: of which powerfail-proof | 500 |
| Traces: Number of configurable Traces | 4 |
| Traces: Memory size per trace, max. | 512 kbyte |
| Diagnostics indication LED: RUN/STOP LED | Yes |
|---|---|
| Diagnostics indication LED: ERROR LED | Yes |
| Diagnostics indication LED: MAINT LED | Yes |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes |
| Diagnostics indication LED: Connection display LINK TX/RX | Yes |
| Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
|---|---|
| Number of available Motion Control resources for technology objects | 1 120 |
| Required Motion Control resources: per speed-controlled axis | 40 |
| Required Motion Control resources: per positioning axis | 80 |
| Required Motion Control resources: per synchronous axis | 160 |
| Required Motion Control resources: per external encoder | 80 |
| Required Motion Control resources: per output cam | 20 |
| Required Motion Control resources: per cam track | 160 |
| Required Motion Control resources: per probe | 40 |
| Positioning axis: Number of positioning axes at motion control cycle of 4 ms (typical value) | 11 |
| Controller: PID_Compact | Yes; Universal PID controller with integrated optimization |
| Controller: PID_3Step | Yes; PID controller with integrated optimization for valves |
| Controller: PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring: High-speed counter | Yes |
| Siemens Eco Profile (SEP) | Siemens EcoTech |
|---|---|
| Recycler Guide available | Yes |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 83.2 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 22.3 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 61.8 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.949 kg |
| signed firmware update | Yes |
|---|---|
| Secure Boot | Yes |
| securely removing data | Yes |
| signaling of security events: via PROFINET | No |
| signaling of security events: via Syslog | Yes |
| signaling of security events: functions as Auditable Event Relay | Yes |
| limiting data record transmission | Yes |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; No condensation |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; No condensation |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Programming Programming language: LAD | Yes |
|---|---|
| Programming Programming language: FBD | Yes |
| Programming Programming language: STL | Yes |
| Programming Programming language: SCL | Yes |
| Programming Programming language: CFC | Yes |
| Programming Programming language: GRAPH | Yes |
| Know-how protection: User program protection/password protection | Yes |
| Know-how protection: Copy protection | Yes |
| Know-how protection: Block protection | Yes |
| Access protection: protection of confidential configuration data | Yes |
| Access protection: Protection level: Write protection | Yes |
| Access protection: Protection level: Read/write protection | Yes |
| Access protection: Protection level: Write protection for Failsafe | No |
| Access protection: Protection level: Complete protection | Yes |
| Access protection: User administration | Yes; device-wide and centralized |
| Access protection: Number of users | 100 |
| Access protection: Number of groups | 100 |
| Access protection: Number of roles | 50 |
| Cycle time monitoring: lower limit | adjustable minimum cycle time |
| Cycle time monitoring: upper limit | adjustable maximum cycle time |
| Width | 100 mm |
|---|---|
| Height | 117 mm |
| Depth | 75 mm |
| Weight, approx. | 265 g |
|---|
| TUEV Manufacturer Declara- China RoHS | tion |
|---|
| FM CCC-Ex Type Examination Cer- | tificate |
|---|
| Net weight | 0.339 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.839 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CPU 1512SP-1 PN is 0.48 A.
The rated operational voltage of CPU 1512SP-1 PN is 24 V AC.
The tariff (HS) code on file for CPU 1512SP-1 PN is 85371091.
The EAN (GTIN) of CPU 1512SP-1 PN is 4047623412731.
CPU 1512SP-1 PN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.