How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7505-0KA00-0AB0 is a SIMATIC S7-1500 system power supply that feeds 25 W into the backplane bus from a 24 V DC input (19.2 to 28.8 V), drawing 1.3 A rated current with 20 ms mains buffering. It includes reverse-polarity and short-circuit protection and dissipates 6.2 W at nominal load.
The 25 W infeed budget is sized for the backplane bus and connected module electronics, not for powering field loads directly, so the configured rack's total module current draw needs to stay inside that 25 W ceiling per TIA Portal's power calculation; step up to a higher-wattage supply in the family once that budget is exceeded. The wider -25 to 60 degC horizontal rating versus -25 to 40 degC vertical is a factor when choosing panel orientation for hot cabinets.
Feeding the S7-1500 backplane bus (CPU plus connected I/O modules) in a standard control cabinet, including installations up to 5,000 m altitude or 60 degC ambient in horizontal mounting.
| Product type designation | PS 25W 24VDC |
|---|---|
| HW functional status | from FS01 |
| Firmware version | from V1.0.0 |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V12 / V12 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 or higher |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V; Static 19.2 V, dynamic 18.5 V |
| permissible range, upper limit (DC) | 28.8 V; Static 28.8 V, dynamic 30.2 V |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 20 ms |
| Rated value at 24 V DC | 1.3 A |
|---|
| Part number | 6ES7505-0KA00-0AB0 |
|---|---|
| Type designation | PS 25W 24VDC |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4025515079897 |
| ETIM class | EC000599 |
| eCl@ss | 27242209 |
| Short-circuit protection | Yes |
|---|
| Infeed power to the backplane bus | 25 W |
|---|
| Power loss at nominal rating conditions | 6.2 W |
|---|
| Status indicator | Yes |
|---|
| primary/secondary | Yes |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Interference immunity against voltage surge: Interference immunity on supply lines acc. to IEC 61000- | Yes; ±1 kV (acc. to IEC 61000-4-5; 1995; surge symm.), ±2 kV (acc. to IEC |
|---|---|
| 4-5 | 61000-4-5; 1995; surge asymm.), no external protective circuit required |
| Equipment protection class | III, with protective conductor |
|---|
| Ambient temperature during operation: min. | -25 °C; up to FS03: 0 °C |
|---|---|
| Ambient temperature during operation: max. | 60 °C |
| Ambient temperature during operation: horizontal installation, min. | -25 °C; up to FS03: 0 °C |
| Ambient temperature during operation: vertical installation, min. | -25 °C; up to FS03: 0 °C |
| Ambient temperature during storage/transportation: min. | -40 °C |
| Ambient temperature during storage/transportation: max. | 70 °C |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Width | 35 mm |
|---|---|
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 350 g |
|---|
| BIS CRS Manufacturer Declara- China RoHS | tion |
|---|
| Net weight | 0.355 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.855 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of PS 25W 24VDC is 1.3 A.
The rated operational voltage of PS 25W 24VDC is 24 V AC.
The rated motor power of PS 25W 24VDC is 0.025 kW.
The tariff (HS) code on file for PS 25W 24VDC is 85044095.
The EAN (GTIN) of PS 25W 24VDC is 4025515079897.
PS 25W 24VDC ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.