Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7431-1KF10-0AB0 SIMATIC S7-400 SM 431 module provides 8 isolated analog inputs at 14-bit resolution, reading voltage, current, resistance, thermocouples (types B, E, J, K, L, N, R, S, T, U) and RTDs (Pt100/200/500/1000/10000, Ni100/1000) on the same channels. Parameterizable temperature compensation supports an external Pt100 sensor or a compensation socket.
This module measures voltage, current, resistance, thermocouples (types B, E, J, K, L, N, R, S, T, U) and RTDs (Pt100/200/500/1000/10000, Ni100/1000) on the same 8 channels – pick it when a panel needs mixed temperature and process signals without dedicating separate modules to each sensor type. Parameterizable temperature compensation supports an external Pt100 reference, a compensation socket, or a dynamic reference value for thermocouple cold-junction correction. Resolution is 14 bit standard, extending to 16 bit with filtering enabled, and basic conversion time is 20.1/23.5 ms per channel. Keep cable runs to 50 m (rather than the standard 200 m) when using thermocouples or the ±80 mV range, since low-level signals are more susceptible to noise pickup over longer runs.
| Load voltage L+: Rated value (DC) | 24 V; Only required for supplying 2-wire transmitters |
|---|---|
| Load voltage L+: Reverse polarity protection | Yes |
| from load voltage L+ (without load), max. | 200 mA; for 8 connected, fully controlled 2-wire transmitters |
|---|---|
| from backplane bus 5 V DC, max. | 600 mA |
| Power loss, typ. | 3.5 W |
|---|
| Part number | 6ES7431-1KF10-0AB0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4025515128984 |
| Number of analog inputs | 8 |
|---|---|
| For voltage/current measurement | 8 |
| For resistance measurement | 4 |
| permissible input voltage for voltage input (destruction limit), max. | 18 V; 18 V continuous, 75 V for 1 ms (mark to space ratio 1:20) |
| permissible input current for current input (destruction limit), max. | 40 mA; Permanent |
| Constant measurement current for resistance-type transmitter, typ. | 1.67 mA |
| Input ranges: Voltage | Yes |
| Input ranges: Current | Yes |
| Input ranges: Thermocouple | Yes |
| Input ranges: Resistance thermometer | Yes |
| Input ranges: Resistance | Yes |
| Input ranges (rated values), voltages: 1 V to 5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (1 V to 5 V) | 1 MΩ |
| Input ranges (rated values), voltages: -1 V to +1 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-1 V to +1 V) | 1 MΩ |
| Input ranges (rated values), voltages: -10 V to +10 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-10 V to +10 V) | 1 MΩ |
| Input ranges (rated values), voltages: -2.5 V to +2.5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-2.5 V to +2.5 V) | 1 MΩ |
| Input ranges (rated values), voltages: -250 mV to +250 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-250 mV to +250 mV) | 1 MΩ |
| Input ranges (rated values), voltages: -5 V to +5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-5 V to +5 V) | 1 MΩ |
| Input ranges (rated values), voltages: -500 mV to +500 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-500 mV to +500 mV) | 1 MΩ |
| Input ranges (rated values), voltages: -80 mV to +80 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-80 mV to +80 mV) | 1 MΩ |
| Input ranges (rated values), currents: 0 to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (0 to 20 mA) | 50 Ω |
| Input ranges (rated values), currents: 4 mA to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (4 mA to 20 mA) | 50 Ω |
| Input ranges (rated values), thermocouples: Type B | Yes |
| Input ranges (rated values), thermocouples: Input resistance (Type B) | 1 MΩ |
| Input ranges (rated values), thermocouples: Type E | Yes |
| Input ranges (rated values), thermocouples: Type J | Yes |
| Input ranges (rated values), thermocouples: Type K | Yes |
| Input ranges (rated values), thermocouples: Type L | Yes |
| Input ranges (rated values), thermocouples: Type N | Yes |
| Input ranges (rated values), thermocouples: Type R | Yes |
| Input ranges (rated values), thermocouples: Type S | Yes |
| Input ranges (rated values), thermocouples: Type T | Yes |
| Input ranges (rated values), thermocouples: Type U | Yes |
| Input ranges (rated values), resistance thermometer: Ni 100 | Yes |
| Input ranges (rated values), resistance thermometer: Input resistance (Ni 100) | 1 MΩ |
| Input ranges (rated values), resistance thermometer: Ni 1000 | Yes |
| Input ranges (rated values), resistance thermometer: Pt 100 | Yes |
| Input ranges (rated values), resistance thermometer: Pt 1000 | Yes |
| Input ranges (rated values), resistance thermometer: Pt 10000 | Yes |
| Input ranges (rated values), resistance thermometer: Pt 200 | Yes |
| Input ranges (rated values), resistance thermometer: Pt 500 | Yes |
| Input ranges (rated values), resistors: 0 to 48 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 48 ohms) | 1 MΩ |
| Input ranges (rated values), resistors: 0 to 150 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 150 ohms) | 1 MΩ |
| Input ranges (rated values), resistors: 0 to 300 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 300 ohms) | 1 MΩ |
| Input ranges (rated values), resistors: 0 to 600 ohms | Yes |
| Input ranges (rated values), resistors: Input resistance (0 to 600 ohms) | 1 MΩ |
| Input ranges (rated values), resistors: 0 to 6000 ohms | Yes; Usable up to 5000 Ohm |
| Thermocouple (TC) Temperature compensation: Parameterizable | Yes |
| Thermocouple (TC) Temperature compensation: internal temperature compensation | No |
| Thermocouple (TC) Temperature compensation: external temperature compensation with Pt100 | Yes |
| Thermocouple (TC) Temperature compensation: dynamic reference temperature value | Yes |
| Characteristic linearization: Parameterizable | Yes |
| Characteristic linearization: for thermocouples | Type B, E, J, K, L, N, R, S, T, U |
| Characteristic linearization: for resistance thermometer | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 |
| Cable length: shielded, max. | 200 m; 50 m with thermocouples and input ranges ≤ 80 mV |
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 14 bit; with activated filtering: 16 bit |
|---|---|
| Integration and conversion time/resolution per channel: Integration time, parameterizable | Yes |
| Integration and conversion time/resolution per channel: Basic conversion time (ms) | 20.1 / 23.5 ms |
| Integration and conversion time/resolution per channel: Interference voltage suppression for interference frequency f1 in Hz | 50 / 60 Hz |
| Connection of signal encoders: for voltage measurement | Yes; possible |
|---|---|
| Connection of signal encoders: for current measurement as 2-wire transducer | Yes |
| Connection of signal encoders: for current measurement as 4-wire transducer | Yes |
| Connection of signal encoders: for resistance measurement with two-wire connection | Yes; Line resistances are also measured |
| Temperature error (relative to input range), (+/-) | 0.004 %/K |
|---|---|
| Operational error limit in overall temperature range: Voltage, relative to input range, (+/-) | 0.38 %; ±0.38 % at ±80 mV; ±0.35 % at ±250 mV, ±500 mV, ±1 V, ±2,5 V, ±5 V, 1 to 5 V, ±10 V |
| Operational error limit in overall temperature range: Current, relative to input range, (+/-) | 0.35 %; ±20 mA, 0 to 20 mA, 4 to 20 mA |
| Operational error limit in overall temperature range: Resistance, relative to input range, (+/-) | 0.5 % |
| Operational error limit in overall temperature range: Thermocouple, relative to input range, (+/-) | TC Type B (±14.8 K), TC Type R (±9.4 K), TC Type S (±10.6 K), TC Type T (±2.2 K), TC Type E (±4.0 K), TC Type J (±5.2 K), TC Type K (±7.6 K), TC Type U (±3.5 K), TC Type L (±5.1 K), TC Type N (±5.5 K) |
| Basic error limit (operational limit at 25 °C): Voltage, relative to input range, (+/-) | 0.15 %; ±0.15 % (±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, 1 to 5 V, ±10 V); ±0.17% (±80 mV) |
| Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) | 0.15 %; ±20 mA, 0 to 20 mA, 4 to 20 mA |
| Basic error limit (operational limit at 25 °C): Resistance, relative to input range, (+/-) | 0.15 %; ±0.15 % at 0 to 48 ohms (4-conductor measurement), 0 to 150 ohms (4-conductor measurement), 0 to 300 ohms (4-conductor measurement), 0 to 600 ohms (4-conductor measurement), 0 to 5000 ohms (4-conductor measurement, in range of 6000 ohms); ±0.3 % at 0 to 300 ohms (3-conductor measurement), 0 to 600 ohms (3-conductor measurement), 0 to 5000 ohms (3- conductor measurement, in range of 6000 ohms) |
| Basic error limit (operational limit at 25 °C): Resistance thermometer, relative to input range, (+/-) | 0.3 % |
| Basic error limit (operational limit at 25 °C): Thermocouple, relative to input range, (+/-) | TC Type B (±8.2 K), TC Type R (±5.2 K), TC Type S (±5.9 K), TC Type T (±1.2 K), TC Type E (±1.8 K), TC Type J (±2.3 K), TC Type K (±3.4 K), TC Type U (±1.8 K), TC Type L (±2.3 K), TC Type N (±2.9 K) |
| Diagnostics function | No |
|---|
| Potential separation analog inputs: Potential separation analog inputs | Yes; internal/external |
|---|---|
| Potential separation analog inputs: between the channels | No |
| Potential separation analog inputs: between the channels and backplane bus | Yes |
| Isolation tested with V DC between L+/M and local ground | 2 120 V DC between bus and L+/M; 2 120 V DC between bus and analog section; 500 V DC between bus and local ground; 500 V DC between analog section and L+/M; 2 120 V DC between analog section and local ground; 2 120 |
|---|
| eClass | 16 27-24-22-01 |
|---|---|
| ETIM | 10 EC001420 |
| IDEA | 4 3562 |
| UNSPSC | 15 32-15-17-05 |
| Net weight | 0.788 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.288 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for 6ES7431-1KF10-0AB0 is 85389091.
The EAN (GTIN) of 6ES7431-1KF10-0AB0 is 4025515128984.
6ES7431-1KF10-0AB0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.