Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7431-0HH00-0AB0 SIMATIC S7-400 SM 431 module provides 16 non-isolated analog inputs at 13-bit resolution, covering voltage ranges up to plus/minus 10 V and current ranges up to plus/minus 20 mA and 4-20 mA. An onboard 24 V DC supply powers up to 16 two-wire transmitters directly, and basic conversion time is 55 or 65 ms per channel depending on the interference-suppression setting.
Sixteen non-isolated analog inputs share a common reference to the backplane, which fits applications where sensors share the same ground and channel count matters more than per-channel isolation. The onboard 24 V DC supply (up to 400 mA for all 16 channels) powers 2-wire, loop-current transmitters directly, so 4-20 mA sensors need no separate power source. Voltage ranges cover ±1 V, ±10 V and 1-5 V, and current ranges cover ±20 mA and 4-20 mA, all at 13-bit resolution with sign. Basic conversion time is 55 or 65 ms per channel depending on the 50/60 Hz interference-suppression setting selected.
| Load voltage L+: Rated value (DC) | 24 V; Only required for supplying 2-wire transmitters |
|---|---|
| Load voltage L+: Reverse polarity protection | Yes |
| from load voltage L+ (without load), max. | 400 mA; for 16 connected, fully controlled 2-wire transmitters |
|---|---|
| from backplane bus 5 V DC, max. | 100 mA |
| Power loss, typ. | 2 W |
|---|
| Part number | 6ES7431-0HH00-0AB0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4025515128960 |
| Number of analog inputs | 16 |
|---|---|
| For voltage/current measurement | 16 |
| permissible input voltage for voltage input (destruction limit), max. | 20 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20) |
| permissible input current for current input (destruction limit), max. | 40 mA |
| Constant measurement current for resistance-type transmitter, typ. | 1.67 mA |
| Input ranges: Voltage | Yes |
| Input ranges: Current | Yes |
| Input ranges: Thermocouple | No |
| Input ranges: Resistance thermometer | No |
| Input ranges: Resistance | No |
| Input ranges (rated values), voltages: 1 V to 5 V | Yes |
| Input ranges (rated values), voltages: Input resistance (1 V to 5 V) | 100 kΩ |
| Input ranges (rated values), voltages: -1 V to +1 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-1 V to +1 V) | 10 MΩ |
| Input ranges (rated values), voltages: -10 V to +10 V | Yes |
| Input ranges (rated values), voltages: Input resistance (-10 V to +10 V) | 100 kΩ |
| Input ranges (rated values), currents: -20 mA to +20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (-20 mA to +20 mA) | 50 Ω |
| Input ranges (rated values), currents: 4 mA to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (4 mA to 20 mA) | 50 Ω |
| Cable length: shielded, max. | 200 m |
| Analog value generation for the inputs Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 13 bit |
| Connection of signal encoders: for voltage measurement | Yes; possible |
|---|---|
| Connection of signal encoders: for current measurement as 4-wire transducer | Yes |
| Temperature error (relative to input range), (+/-) | 0.01 %/K |
|---|---|
| Operational error limit in overall temperature range: Voltage, relative to input range, (+/-) | 0.65 %; 1.0 % at 1 to 5 V; 0.65 % at ±1 V, ±10 V |
| Operational error limit in overall temperature range: Current, relative to input range, (+/-) | 0.65 % |
| Basic error limit (operational limit at 25 °C): Voltage, relative to input range, (+/-) | 0.25 %; 0.5% at 1 to 5 V; 0.25% at ±1 V, ±10 V |
| Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) | 0.25 %; at ±20 mA, 4 to 20 mA |
| Diagnostics function | No |
|---|
| Potential separation analog inputs: Potential separation analog inputs | No |
|---|---|
| Potential separation analog inputs: between the channels | No |
| Potential separation analog inputs: between the channels and backplane bus | No |
| Isolation tested with | 500 V AC/707 V DC, type test |
|---|
| Width | 25 mm |
|---|---|
| Height | 290 mm |
| Depth | 210 mm |
| Weight, approx. | 500 g |
|---|
| Net weight | 0.826 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.326 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for 6ES7431-0HH00-0AB0 is 85389091.
The EAN (GTIN) of 6ES7431-0HH00-0AB0 is 4025515128960.
6ES7431-0HH00-0AB0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.