Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7422-1HH00-0AA0 SIMATIC S7-400 SM 422 module provides 16 isolated relay outputs rated 5 A, switching up to 230 V AC or 60 V DC per channel. Relays are rated for 100,000 electrical switching cycles at AC-15/DC-13 duty and 3,000,000 mechanical cycles, with channels isolated in groups of 2. Switching capacity falls to 0.2 A at 125 V DC.
Relay outputs make this module the choice when a load needs galvanic isolation across a wide voltage range – up to 230 V AC or 60 V DC on the same channel, unlike the solid-state DC-only or AC-only output modules. Rated for 100,000 switching operations at AC-15/DC-13 duty (3,000,000 mechanically), it fits loads that switch a few times per hour rather than continuously. Switching capacity drops with DC load voltage: 5 A at 30 V DC but only 0.2 A at 125 V DC, so check the actual DC load voltage before sizing the circuit. Channels are isolated in groups of 2, allowing different voltage classes across the 16 relays.
| Load voltage L+: Rated value (DC) | 60 V |
|---|---|
| Load voltage L+: permissible range, lower limit (DC) | 1 V |
| Load voltage L+: permissible range, upper limit (DC) | 60 V |
| Load voltage L1: Rated value (AC) | 230 V |
| Load voltage L1: permissible range, lower limit (AC) | 2 V |
| Load voltage L1: permissible range, upper limit (AC) | 264 V |
| from backplane bus 5 V DC, max. | 1 A |
|---|
| Power loss, typ. | 4.5 W |
|---|
| Part number | 6ES7422-1HH00-0AA0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4019169046107 |
| Number of digital outputs | 16; Relays |
|---|---|
| Short-circuit protection | No |
| Controlling a digital input | Yes; possible |
| Size of motor starters according to NEMA, max. | Size 5 according to NEMA |
| Switching capacity of the outputs: on lamp load, max. | 60 W |
| Output current: for signal "1" rated value | 5 A |
| Output current: for signal "1" minimum load current | 11 mA |
| Parallel switching of two outputs: for uprating | No; Not possible |
| Parallel switching of two outputs: for redundant control of a load | Yes; Possible (only outputs with the same load voltage) |
| Switching frequency: with resistive load, max. | 10 Hz |
| Switching frequency: With inductive load (to IEC 60947-5-1, DC13/AC15), max. | 1 Hz |
| Switching frequency: on lamp load, max. | 1 Hz |
| Switching frequency: mechanical, max. | 20 Hz |
| Total current of the outputs (per group) all mounting positions: up to 40 °C, max. | 10 A; 10 A with fan subassembly |
| Relay outputs: Number of operating cycles, max. Switching capacity of contacts | 100 000; 100 000 (AC-15 / DC-13); 3 000 000 mechanical |
| Relay outputs: with inductive load, max. | 5 A; 5 A (30 V DC), 5 A (230 V AC) |
| Relay outputs: with resistive load, max. | 5 A; 5 A (30 V DC), 5 A (230 V AC), 1.2 A (60 V DC), 0.2 A (125 V DC) |
| Relay outputs: Thermal continuous current, max. | 5 A |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 600 m |
| Diagnostics function | No |
|---|---|
| Diagnostics indication LED: Status indicator digital output (green) | Yes; per channel |
| Potential separation digital outputs: between the channels | Yes |
|---|---|
| Potential separation digital outputs: between the channels, in groups of | 2 |
| Potential separation digital outputs: between the channels and backplane bus | Yes |
| Isolation tested with | 1 500 V AC |
|---|
| Width | 25 mm |
|---|---|
| Height | 290 mm |
| Depth | 210 mm |
| Weight, approx. | 700 g |
|---|
| General Product Approval Miscellaneous | For use in hazard- |
|---|---|
| General Product Approval EMV | ous locations |
| Net weight | 0.879 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.379 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 6ES7422-1HH00-0AA0 is 5 A.
The rated operational voltage of 6ES7422-1HH00-0AA0 is 230 V AC.
The tariff (HS) code on file for 6ES7422-1HH00-0AA0 is 85389091.
The EAN (GTIN) of 6ES7422-1HH00-0AA0 is 4019169046107.
6ES7422-1HH00-0AA0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.