The Siemens 6ES7416-3FS07-0AB0 is a SIMATIC S7-400 CPU 416F-3 PN/DP fail-safe central processing unit with 16 MB of work memory (8 MB code, 8 MB data) and three interfaces: MPI/DP at 12 Mbit/s, an Ethernet/PROFINET port, and a slot for a plug-in IF 964-DP module. It integrates 1 PROFINET IO controller and 1 DP master.
The F in CPU 416F-3 PN/DP marks the fail-safe program processing built into this CPU, running standard and safety-related logic on the same module instead of a separate safety CPU. It carries the same 16 MB work memory and PROFINET-plus-PROFIBUS DP interface pairing as the non-fail-safe 416-3 PN/DP, so where a machine has no safety-related I/O to process, the standard CPU 416-3 PN/DP is the lighter choice; where SIL- or PL-rated safety functions run alongside standard control, this F-CPU covers both on one module.
S7-400 control tasks that mix standard automation logic with fail-safe functions (E-stops, safety interlocks, guard monitoring) on a single CPU, over a combined PROFINET and PROFIBUS DP network.
| Product type designation | CPU 416F-3 PN/DP |
|---|---|
| HW functional status | 01 |
| Firmware version | V7.0 |
| Product function: Isochronous mode | Yes; Via PROFIBUS DP or PROFINET interface |
| Engineering with: Programming package | STEP 7 V5.5 or higher with HSP 262 |
| CiR synchronization time, basic load | 100 ms |
|---|---|
| CiR synchronization time, time per I/O byte | 10 µs |
| Rated value (DC) | Power supply via system power supply |
|---|
| Part number | 6ES7416-3FS07-0AB0 |
|---|---|
| Type designation | CPU 416F-3 PN/DP |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4047622230183 |
| ETIM class | EC000236 |
| eCl@ss | 27242207 |
| from backplane bus 5 V DC, typ. | 1.3 A |
|---|---|
| from backplane bus 5 V DC, max. | 1.6 A |
| from backplane bus 24 V DC, max. | 300 mA; 150 mA per DP interface |
| from interface 5 V DC, max. | 90 mA; At each DP interface |
| Power loss, typ. | 6.5 W |
|---|
| Type of memory | RAM |
|---|---|
| Work memory: integrated | 16 Mbyte |
| Work memory: integrated (for program) | 8 Mbyte |
| Work memory: integrated (for data) | 8 Mbyte |
| Work memory: expandable | No |
| Load memory: expandable FEPROM | Yes; with Memory Card (FLASH) |
| Load memory: expandable FEPROM, max. | 64 Mbyte |
| Load memory: integrated RAM, max. | 1 Mbyte |
| Load memory: expandable RAM | Yes; with Memory Card (RAM) |
| Load memory: expandable RAM, max. | 64 Mbyte |
| Backup: present | Yes |
| Backup: with battery | Yes; all data |
| Backup: without battery | No |
| Backup battery: Backup current, typ. | 180 µA; up to 40 °C |
|---|---|
| Backup battery: Backup current, max. | 850 µA |
| Backup battery: Backup time, max. | Dealt with in the module data manual with the secondary conditions and the factors of influence |
| Backup battery: Feeding of external backup voltage to CPU | 5 V DC to 15 V DC |
| for bit operations, typ. | 12.5 ns |
|---|---|
| for word operations, typ. | 12.5 ns |
| for fixed point arithmetic, typ. | 12.5 ns |
| for floating point arithmetic, typ. | 25 ns |
| DB: Number, max. | 10 000; Number range: 1 to 16000 |
|---|---|
| DB: Size, max. | 64 kbyte |
| FB: Number, max. | 5 000; Number range: 0 to 7999 |
| FB: Size, max. | 64 kbyte |
| FC: Number, max. | 5 000; Number range: 0 to 7999 |
| FC: Size, max. | 64 kbyte |
| OB: Number, max. | see instruction list |
| OB: Size, max. | 64 kbyte |
| OB: Number of free cycle OBs | 1; OB 1 |
| OB: Number of time alarm OBs | 8; OB 10-17 |
| OB: Number of delay alarm OBs | 4; OB 20-23 |
| OB: Number of cyclic interrupt OBs | 9; OB 30-38 (shortest cycle that can be set = 500 µs) |
| OB: Number of process alarm OBs | 8; OB 40-47 |
| OB: Number of DPV1 alarm OBs | 3; OB 55-57 |
| OB: Number of isochronous mode OBs | 4; OB 61-64 |
| OB: Number of multicomputing OBs | 1; OB 60 |
| OB: Number of background OBs | 1; OB 90 |
| OB: Number of startup OBs | 2; OB 100, 102 |
| OB: Number of asynchronous error OBs | 9; OB 80-88 |
| OB: Number of synchronous error OBs | 2; OB 121, 122 |
| Nesting depth: per priority class | 24 |
| Nesting depth: additional within an error OB | 2 |
| S7 counter: Number Retentivity | 2 048 |
|---|---|
| S7 counter: adjustable | Yes |
| S7 counter: preset Counting range | Z 0 to Z 7 |
| S7 counter: lower limit | 0 |
| S7 counter: upper limit | 999 |
| IEC counter: present | Yes |
| IEC counter: Type | SFB |
| IEC counter: Number | Unlimited (limited only by RAM capacity) |
| S7 timer: Number Retentivity | 2 048 |
| S7 timer: adjustable | Yes |
| S7 timer: preset Time range | No times retentive |
| S7 timer: lower limit | 10 ms |
| S7 timer: upper limit | 9 990 s |
| IEC timer: present | Yes |
| IEC timer: Type | SFB |
| IEC timer: Number | Unlimited (limited only by RAM capacity) |
| Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) |
|---|---|
| Flag: Size, max. | 16 kbyte; Size of bit memory address area |
| Flag: Retentivity available | Yes |
| Flag: Retentivity preset | MB 0 to MB 15 |
| Flag: Number of clock memories | 8; in 1 memory byte |
| Local data: adjustable, max. | 32 kbyte |
| Local data: preset | 16 kbyte |
| I/O address area: Inputs | 16 kbyte |
|---|---|
| I/O address area: Outputs | 16 kbyte |
| Process image: Inputs, adjustable | 16 kbyte |
| Process image: Outputs, adjustable | 16 kbyte |
| Process image: Inputs, default | 512 byte |
| Process image: Outputs, default | 512 byte |
| Process image: consistent data, max. | 244 byte |
| Process image: Access to consistent data in process image | Yes |
| Subprocess images: Number of subprocess images, max. | 15 |
| Digital channels: Inputs | 131 072 |
| Digital channels: of which central | 131 072 |
| Digital channels: Outputs | 131 072 |
| Analog channels: Inputs | 8 192 |
| Analog channels: of which central | 8 192 |
| Analog channels: Outputs | 8 192 |
| Number of expansion units, max. | 21 |
|---|---|
| connectable OPs | 95 |
| Multicomputing | Yes; 4 CPUs max. (with UR1 or UR2) |
| Interface modules: Number of connectable IMs (total), max. | 6 |
| Interface modules: Number of connectable IM 460s, max. | 6 |
| Interface modules: Number of connectable IM 463s, max. | 4; IM 463-2 |
| Number of DP masters: integrated | 1 |
| Number of DP masters: via CP | 10; CP 443-5 Extended |
| Number of DP masters: via IM 467 | 4 |
| Number of DP masters: Mixed mode IM + CP permitted | No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode |
| Number of DP masters: via interface module | 1; IF 964-DP |
| Number of DP masters: Number of pluggable S5 modules (via adapter capsule in central device), max. | 6 |
| Number of IO Controllers: Integrated | 1 |
| Number of IO Controllers: Via CP | 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode |
| Number of operable FMs and CPs (recommended): FM | Limited by number of slots or number of connections |
| Number of operable FMs and CPs (recommended): CP, PtP | CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections |
| Number of operable FMs and CPs (recommended): PROFIBUS and Ethernet CPs | 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller |
| Slots: required slots | 2 |
| Clock: Hardware clock (real-time) | Yes |
|---|---|
| Clock: retentive and synchronizable | Yes |
| Clock: Resolution | 1 ms |
| Clock: Deviation per day (buffered), max. | 1.7 s; Power off |
| Clock: Deviation per day (unbuffered), max. | 8.6 s; For power On |
| Operating hours counter: Number | 16 |
| Operating hours counter: Number/Number range | 0 to 15 |
| Operating hours counter: Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours |
| Operating hours counter: Granularity | 1 h |
| Operating hours counter: retentive | Yes |
| Clock synchronization: supported | Yes |
| Clock synchronization: to MPI, master | Yes |
| Clock synchronization: on MPI, device | Yes |
| Clock synchronization: to DP, master | Yes |
| Clock synchronization: on DP, device | Yes |
| Clock synchronization: in AS, master | Yes |
| Clock synchronization: in AS, device | Yes |
| Clock synchronization: on Ethernet via NTP | Yes; As client |
| Clock synchronization: to IF 964 DP | Yes |
| Time difference in system when synchronizing via: Ethernet, max. | 10 ms |
| Time difference in system when synchronizing via: MPI, max. | 200 ms |
| Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports), 1 x PROFIBUS DP (optionally pluggable) |
|---|---|
| Number of RS 485 interfaces | 1; Combined MPI / PROFIBUS DP |
| Number of other interfaces | 1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04- 0AB0) |
| Interface type | MPI/PROFIBUS DP |
|---|---|
| Isolated | Yes |
| Interface types: RS 485 | Yes |
| Interface types: Output current of the interface, max. | 150 mA |
| Protocols: MPI | Yes |
| Protocols: PROFIBUS DP master | Yes |
| Protocols: PROFIBUS DP device | Yes |
| MPI: Number of connections | 44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| MPI: Transmission rate, max. Services | 12 Mbit/s |
| MPI: PG/OP communication | Yes |
| MPI: Routing | Yes |
| MPI: Global data communication | Yes |
| MPI: S7 basic communication | Yes |
| MPI: S7 communication | Yes |
| MPI: S7 communication, as client | Yes |
| MPI: S7 communication, as server | Yes |
| PROFIBUS DP master: Number of connections, max. | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| PROFIBUS DP master: Transmission rate, max. | 12 Mbit/s |
| PROFIBUS DP master: max. number of DP devices Services | 32 |
| PROFIBUS DP master: PG/OP communication | Yes |
| PROFIBUS DP master: Routing | Yes; S7 routing |
| PROFIBUS DP master: Global data communication | No |
| PROFIBUS DP master: S7 basic communication | Yes |
| PROFIBUS DP master: S7 communication | Yes |
| PROFIBUS DP master: S7 communication, as client | Yes |
| PROFIBUS DP master: S7 communication, as server | Yes |
| PROFIBUS DP master: Equidistance | Yes |
| PROFIBUS DP master: Isochronous mode | Yes |
| PROFIBUS DP master: SYNC/FREEZE | Yes |
| PROFIBUS DP master: activation/deactivation of DP devices | Yes |
| PROFIBUS DP master: Direct data exchange (slave-to-slave communication) | Yes |
| PROFIBUS DP master: DPV1 Address area | Yes |
| PROFIBUS DP master: Inputs, max. | 2 kbyte |
| PROFIBUS DP master: Outputs, max. User data per DP device | 2 kbyte |
| PROFIBUS DP master: user data per DP device, max. | 244 byte |
| PROFIBUS DP master: Outputs, max. | 244 byte |
| PROFIBUS DP master: Slots, max. | 244 |
| PROFIBUS DP master: per slot, max. | 128 byte |
| PROFIBUS DP device: Number of connections | 32 |
| PROFIBUS DP device: Transmission rate, max. | 12 Mbit/s |
| PROFIBUS DP device: automatic baud rate search | No |
| PROFIBUS DP device: Address area, max. | 32; Virtual slots |
| PROFIBUS DP device: User data per address area, max. | 32 byte |
| PROFIBUS DP device: of which consistent, max. Services | 32 byte |
| PROFIBUS DP device: PG/OP communication | Yes; with interface active |
| PROFIBUS DP device: Routing | Yes; with interface active |
| PROFIBUS DP device: Global data communication | No |
| PROFIBUS DP device: S7 basic communication | No |
| PROFIBUS DP device: S7 communication | Yes |
| PROFIBUS DP device: S7 communication, as client | Yes |
| PROFIBUS DP device: S7 communication, as server | Yes |
| PROFIBUS DP device: Direct data exchange (slave-to-slave communication) | No |
| PROFIBUS DP device: DPV1 Transfer memory | No |
| PROFIBUS DP device: Inputs | 244 byte |
| PROFIBUS DP device: Outputs | 244 byte |
| Interface type | PROFINET |
|---|---|
| Isolated | Yes |
| automatic detection of transmission rate | Yes; Autosensing |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Change of IP address at runtime, supported | Yes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF" |
| Interface types: RJ 45 (Ethernet) | Yes |
| Interface types: Number of ports | 2 |
| Interface types: integrated switch | Yes |
| Protocols: PROFINET IO Controller | Yes |
| Protocols: PROFINET IO Device | Yes |
| Protocols: PROFINET CBA | Yes |
| Protocols: PROFIBUS DP master | No |
| Protocols: PROFIBUS DP device | No |
| Protocols: Open IE communication | Yes |
| Protocols: Web server | Yes |
| Protocols: Point-to-point connection | No |
| Protocols: Media redundancy | Yes |
| PROFINET IO Controller: Transmission rate, max. Services | 100 Mbit/s |
| PROFINET IO Controller: PG/OP communication | Yes |
| PROFINET IO Controller: S7 communication | Yes |
| PROFINET IO Controller: Isochronous mode | Yes; Only with IRT and the High Performance option |
| PROFINET IO Controller: Shared device | Yes |
| PROFINET IO Controller: Prioritized startup | Yes |
| PROFINET IO Controller: Number of IO devices with prioritized startup, max. | 32 |
| PROFINET IO Controller: Number of connectable IO Devices, max. | 256 |
| PROFINET IO Controller: Of which IO devices with IRT, max. | 64 |
| PROFINET IO Controller: of which in line, max. | 64 |
| PROFINET IO Controller: Number of IO Devices with IRT and the option "high flexibility" | 256 |
| PROFINET IO Controller: Number of connectable IO Devices for RT, max. | 256 |
| PROFINET IO Controller: Activation/deactivation of IO Devices | Yes |
| PROFINET IO Controller: Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| PROFINET IO Controller: IO Devices changing during operation (partner ports), supported | Yes |
| PROFINET IO Controller: Number of IO Devices per tool, max. | 8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported |
| PROFINET IO Controller: Device replacement without swap medium | Yes |
| PROFINET IO Controller: Send cycles | 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame |
| PROFINET IO Controller: Updating time Address area | 250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description |
| PROFINET IO Controller: Inputs, max. | 8 kbyte |
| PROFINET IO Controller: Outputs, max. | 8 kbyte |
| PROFINET IO Controller: User data consistency, max. | 1 024 byte |
| PROFINET IO Device Services: PG/OP communication | Yes |
| PROFINET IO Device Services: S7 communication | Yes |
| PROFINET IO Device Services: Isochronous mode | No |
| PROFINET IO Device Services: IRT | Yes |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. Transfer memory | 2 |
| PROFINET IO Device Services: Inputs, max. | 1 440 byte; Per IO Controller with shared device |
| PROFINET IO Device Services: Outputs, max. Submodules | 1 440 byte; Per IO Controller with shared device |
| PROFINET IO Device Services: Number, max. | 64 |
| PROFINET IO Device Services: User data per submodule, max. | 1 024 byte |
| PROFINET CBA: acyclic transmission | Yes |
| PROFINET CBA: cyclic transmission | Yes |
| Open IE communication: Number of connections, max. | 94 |
| Open IE communication: Local port numbers used at the system end | 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
| Open IE communication: Keep-alive function, supported | Yes |
| Interface type | Pluggable interface module (IF) |
|---|---|
| Plug-in interface modules | IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) |
| Isolated | Yes |
| automatic detection of transmission rate | No |
| Interface types: RS 485 | Yes |
| Interface types: Output current of the interface, max. | 150 mA |
| Protocols: MPI | No |
| Protocols: PROFIBUS DP master | Yes |
| Protocols: PROFIBUS DP device | Yes |
| PROFIBUS DP master: Number of connections, max. | 32 |
| PROFIBUS DP master: Transmission rate, max. | 12 Mbit/s |
| PROFIBUS DP master: max. number of DP devices Services | 125 |
| PROFIBUS DP master: PG/OP communication | Yes |
| PROFIBUS DP master: Routing | Yes; S7 routing |
| PROFIBUS DP master: Global data communication | No |
| PROFIBUS DP master: S7 basic communication | Yes |
| PROFIBUS DP master: S7 communication | Yes |
| PROFIBUS DP master: S7 communication, as client | Yes |
| PROFIBUS DP master: S7 communication, as server | Yes |
| PROFIBUS DP master: Equidistance | Yes |
| PROFIBUS DP master: Isochronous mode | Yes |
| PROFIBUS DP master: SYNC/FREEZE | Yes |
| PROFIBUS DP master: activation/deactivation of DP devices | Yes |
| PROFIBUS DP master: Direct data exchange (slave-to-slave communication) | Yes |
| PROFIBUS DP master: DPV0 | Yes |
| PROFIBUS DP master: DPV1 Address area | Yes |
| PROFIBUS DP master: Inputs, max. | 8 kbyte |
| PROFIBUS DP master: Outputs, max. User data per DP device | 8 kbyte |
| PROFIBUS DP master: user data per DP device, max. | 244 byte |
| PROFIBUS DP master: Outputs, max. | 244 byte |
| PROFIBUS DP master: Slots, max. | 244 |
| PROFIBUS DP master: per slot, max. | 128 byte |
| PROFIBUS DP device: Number of connections | 32 |
| PROFIBUS DP device: Transmission rate, max. | 12 Mbit/s |
| PROFIBUS DP device: automatic baud rate search | No |
| PROFIBUS DP device: Address area, max. | 32; Virtual slots |
| PROFIBUS DP device: User data per address area, max. | 32 byte |
| PROFIBUS DP device: of which consistent, max. Services | 32 byte |
| PROFIBUS DP device: PG/OP communication | Yes |
| PROFIBUS DP device: Routing | Yes; with interface active |
| PROFIBUS DP device: Global data communication | No |
| PROFIBUS DP device: S7 basic communication | No |
| PROFIBUS DP device: S7 communication | Yes |
| PROFIBUS DP device: S7 communication, as client | Yes |
| PROFIBUS DP device: S7 communication, as server | Yes |
| PROFIBUS DP device: Direct data exchange (slave-to-slave communication) | No |
| PROFIBUS DP device: DPV1 Transfer memory | No |
| PROFIBUS DP device: Inputs | 244 byte |
| PROFIBUS DP device: Outputs | 244 byte |
| Redundancy mode Media redundancy: Switchover time on line break, typ. | 200 ms |
|---|---|
| Redundancy mode Media redundancy: Number of stations in the ring, max. | 50 |
| SIMATIC communication: S7 routing | Yes |
| Open IE communication: TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
| Open IE communication: Number of connections, max. | 94 |
| Open IE communication: Data length, max. | 32 kbyte |
| Open IE communication: several passive connections per port, supported | Yes |
| Open IE communication: ISO-on-TCP (RFC1006) | Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs |
| Open IE communication: UDP | Yes; via integrated PROFINET interface and loadable FBs |
| Web server: supported | Yes |
| Web server: User-defined websites | Yes |
| Web server: Number of HTTP clients | 5 |
| Equidistance | Yes |
|---|---|
| Number of DP masters with isochronous mode | 2 |
| payload per isochronous device, max. | 244 byte |
| shortest clock pulse | 1 ms; 0.5 ms without use of SFC 126, 127 |
| max. cycle | 32 ms |
| PG/OP communication | Yes |
|---|---|
| Number of connectable OPs with message processing | 95; When using Alarm_S/SQ and Alarm_D/DQ |
| Number of connectable OPs without message processing | 95 |
| Data record routing | Yes |
| Global data communication: supported | Yes |
| Global data communication: Number of GD loops, max. | 16 |
| Global data communication: Number of GD packets, transmitter, max. | 16 |
| Global data communication: Number of GD packets, receiver, max. | 32 |
| Global data communication: Size of GD packets, max. | 54 byte |
| Global data communication: Size of GD packet (of which consistent), max. | 1 variable |
| S7 basic communication: supported | Yes |
| S7 basic communication: User data per job, max. | 76 byte |
| S7 basic communication: User data per job (of which consistent), max. | 1 variable |
| S7 communication: supported | Yes |
| S7 communication: as server | Yes |
| S7 communication: as client | Yes |
| S7 communication: User data per job, max. | 64 kbyte |
| S7 communication: User data per job (of which consistent), max. | 462 byte; 1 variable |
| S5 compatible communication: supported | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 |
| S5 compatible communication: User data per job, max. | 8 kbyte |
| S5 compatible communication: User data per job (of which consistent), max. | 240 byte |
| S5 compatible communication: Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 64/64 |
| Standard communication (FMS): supported | Yes; Via CP and loadable FB |
| PROFINET CBA (at set setpoint communication load): Setpoint for the CPU communication load | 20 % |
| PROFINET CBA (at set setpoint communication load): Number of remote interconnection partners | 32 |
| PROFINET CBA (at set setpoint communication load): number of master/device functions | 150 |
| PROFINET CBA (at set setpoint communication load): total of all master/device connections | 6 000 |
| PROFINET CBA (at set setpoint communication load): data length of all incoming master/device connections, max. | 65 000 byte |
| PROFINET CBA (at set setpoint communication load): Number of device-internal and PROFIBUS interconnections | 1 000 |
| PROFINET CBA (at set setpoint communication load): Transmission frequency: Transmission interval, min. | 1 ms; Depending on preset communication load, number of interconnections and data length used |
| PROFINET CBA (at set setpoint communication load): Number of incoming interconnections | 300 |
| PROFINET CBA (at set setpoint communication load): Number of outgoing interconnections | 300 |
| PROFINET CBA (at set setpoint communication load): Number of stations that can log on for HMI variables (PN OPC/iMap) | 2x PN OPC/1x iMap |
| PROFINET CBA (at set setpoint communication load): HMI variable updating | 500 ms |
| PROFINET CBA (at set setpoint communication load): Number of HMI variables | 1 500 |
| PROFINET CBA (at set setpoint communication load): supported | Yes; 32 PROFIBUS slaves max. connectable |
| Number of connections: overall | 96 |
| Number of connections: usable for PG communication | 95 |
| Number of connections: reserved for PG communication | 1 |
| Number of connections: adjustable for PG communication, max. | 0 |
| Number of connections: usable for OP communication | 95 |
| Number of connections: reserved for OP communication | 1 |
| Number of connections: adjustable for OP communication, max. | 0 |
| Number of connections: usable for S7 basic communication | 94 |
| Number of connections: reserved for S7 basic communication | 0 |
| Number of connections: adjustable for S7 basic communication, max. | 0 |
| Number of connections: usable for S7 communication | 94 |
| Number of connections: reserved for S7 communication | 0 |
| Number of connections: adjustable for S7 communication, max. | 0 |
| Number of connections: usable for routing | 47 |
| Number of connections: reserved for routing | 0 |
| Number of connections: adjustable for routing, max. | 0 |
| Number of login stations for message functions, max. | 95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) |
|---|---|
| Symbol-related messages | Yes |
| SCAN procedure | Yes |
| Program alarms | Yes |
| Process diagnostic messages | Yes |
| simultaneously active Alarm_S blocks, max. | 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks |
| Alarm 8-blocks | Yes |
| Number of instances for alarm 8 and S7 communication blocks, max. | 4 000 |
| preset, max. | 600 |
| Process control messages | Yes |
| Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 32 |
| Number of messages: overall, max. | 1 024 |
| Number of messages: in 100 ms grid, max. | 128 |
| Number of messages: in 500 ms grid, max. | 512 |
| Number of messages: in 1000 ms grid, max. | 1 024 |
| Number of additional values: with 100 ms grid, max. | 1 |
| Number of additional values: with 500, 1000 ms grid, max. | 10 |
| Status block | Yes; Up to 16 simultaneously |
|---|---|
| Single step | Yes |
| Number of breakpoints | 16 |
| Status/control: Status/control variable | Yes; Up to 16 variable tables |
| Status/control: Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Status/control: Number of variables, max. | 70; Status/control |
| Forcing: Forcing | Yes |
| Forcing: Forcing, variables | Inputs/outputs, bit memories, distributed I/Os |
| Forcing: Number of variables, max. | 512 |
| Diagnostic buffer: present | Yes |
| Diagnostic buffer: Number of entries, max. | 3 200 |
| Diagnostic buffer: can be set | Yes |
| Diagnostic buffer: preset | 120 |
| Service data: Can be read out | Yes |
| CE mark | Yes |
|---|---|
| CSA approval | Yes |
| UL approval | Yes |
| cULus | Yes |
| FM approval | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| EAC (formerly Gost-R) | Yes |
| Use in hazardous areas: ATEX marking | ATEX II 3G Ex nA IIC T4 Gc |
| Ambient temperature during operation: min. | 0 °C |
|---|---|
| Ambient temperature during operation: max. | 60 °C |
| Configuration software: STEP 7 | Yes |
|---|---|
| Programming: Command set | see instruction list |
| Programming: Nesting levels | 7 |
| Programming: Access to consistent data in process image | Yes |
| Programming: System functions (SFC) | see instruction list |
| Programming: System function blocks (SFB) Programming language | see instruction list |
| Programming: LAD | Yes |
| Programming: FBD | Yes |
| Programming: STL | Yes |
| Programming: SCL | Yes |
| Programming: CFC | Yes |
| Programming: GRAPH | Yes |
| Programming: HiGraph® Number of simultaneously active SFCs | Yes |
| Programming: DPSYC_FR | 2; SFC 11; per interface |
| Programming: D_ACT_DP | 8; SFC 12; per interface |
| Programming: RD_REC | 8; SFC 59; per interface |
| Programming: WR_REC | 8; SFC 58; per interface |
| Programming: WR_PARM | 8; SFC 55; per interface |
| Programming: PARM_MOD | 1; SFC 57; per interface |
| Programming: WR_DPARM | 2; SFC 56; per interface |
| Programming: DPNRM_DG | 8; SFC 13; per interface |
| Programming: RDSYSST | 8; SFC 51 |
| Programming: DP_TOPOL Number of simultaneously active SFBs | 1; SFC 103; per interface |
| Programming: RDREC | 8; SFB 52; per interface, but not more than 32 across all external interfaces |
| Programming: WRREC | 8; SFB 53; per interface, but not more than 32 across all external interfaces |
| Know-how protection: User program protection/password protection | Yes |
| Know-how protection: Block encryption | Yes; With S7 block Privacy |
| Width | 50 mm |
|---|---|
| Height | 290 mm |
| Depth | 219 mm |
| Weight, approx. | 900 g |
|---|
| Net weight | 1.069 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.569 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for CPU 416F-3 PN/DP is 85371091.
The EAN (GTIN) of CPU 416F-3 PN/DP is 4047622230183.
CPU 416F-3 PN/DP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.