The Siemens 6ES7331-7RD00-0AB0 is a SIMATIC S7 SM 331 analog input module with 4 isolated current inputs at 0/4-20 mA, resolution up to 16 bit, and PTB-tested Ex(i) protection for signals from hazardous areas. It draws 250 mA from the 24 V DC load supply, dissipates 3 W, and reads diagnostics for overrange, wire-break, and short-circuit conditions on each channel.
The Ex(i) suffix and PTB test number mark this as the intrinsically-safe variant of the SM 331 family, so pick it when field transmitters sit inside an ATEX Zone 2/22 or FM Class I Division 2 area rather than in the safe zone — a standard SM 331 without Ex(i) cannot be wired into that loop. Four fully isolated 0/4-20 mA channels with 16-bit resolution and 0.1% basic error at 25°C give enough accuracy for process measurements like pressure or flow transmitters that need tight loop calibration.
Reads 0/4-20 mA process transmitters located in hazardous areas — such as pressure, level, or flow sensors in petrochemical, marine, or process plants — where the Ex(i) barrier lets the field wiring run into a Zone 2/22 or Class I Division 2 classified area.
| Load voltage L+: Rated value (DC) | 24 V |
|---|---|
| Load voltage L+: Reverse polarity protection | Yes |
| from load voltage L+ (without load), max. | 250 mA |
|---|---|
| from backplane bus 5 V DC, max. | 60 mA |
| Power supply to the transmitters: Rated value (DC) | 13 V; at 22 mA |
|---|
| Part number | 6ES7331-7RD00-0AB0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4025515061229 |
| Power loss, typ. | 3 W |
|---|
| Number of analog inputs | 4 |
|---|---|
| permissible input current for current input (destruction limit), max. | 40 mA |
| Input ranges: Voltage | No |
| Input ranges: Current | Yes |
| Input ranges: Thermocouple | No |
| Input ranges: Resistance thermometer | No |
| Input ranges: Resistance | No |
| Input ranges (rated values), currents: 0 to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (0 to 20 mA) | 50 Ω |
| Input ranges (rated values), currents: 4 mA to 20 mA | Yes |
| Input ranges (rated values), currents: Input resistance (4 mA to 20 mA) | 50 Ω |
| Cable length: shielded, max. | 200 m |
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit; 10 bit to 15 bit + sign |
|---|---|
| Integration and conversion time/resolution per channel: Integration time, parameterizable | Yes; 2.5 to 100 ms |
| Integration and conversion time/resolution per channel: Interference voltage suppression for interference frequency f1 in Hz | 10 to 400 Hz |
| Connection of signal encoders: for current measurement as 2-wire transducer | Yes |
|---|---|
| Connection of signal encoders: for current measurement as 4-wire transducer | Yes |
| Operational error limit in overall temperature range: Current, relative to input range, (+/-) | 0.45 % |
|---|---|
| Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) | 0.1 % |
| Diagnostics function | Yes |
|---|---|
| Diagnoses: Diagnostic information readable | Yes |
| Diagnoses: Overrange | Yes |
| Diagnoses: Wire-break in signal transmitter cable | Yes |
| Diagnoses: Short-circuit of the signal encoder cable | Yes |
| Diagnostics indication LED: Group error SF (red) | Yes |
| Diagnostics indication LED: Channel fault indicator F (red) | Yes |
| Module for Ex(i) protection | Yes |
|---|---|
| maximum values for connecting terminals for gas group IIC: Uo (no-load voltage), max. | 25.2 V |
| maximum values for connecting terminals for gas group IIC: Io (short-circuit current), max. | 68.5 mA |
| maximum values for connecting terminals for gas group IIC: Po (power output), max. | 431 mW |
| maximum values for connecting terminals for gas group IIC: Co (permissible external capacity), max. | 90 nF |
| maximum values for connecting terminals for gas group IIC: Lo (permissible external inductivity), max. | 7.5 mH |
| Potential separation analog inputs: between the channels | Yes |
|---|---|
| Potential separation analog inputs: between the channels and backplane bus | Yes |
| Use in hazardous areas: ATEX marking | ATEX II 3 G (2) GD Ex nA [ib Gb] [ib IIIC Db] IIC T4 Gc |
|---|---|
| Use in hazardous areas: FM marking | Class I, Division 2, Group A, B, C, D T4 |
| Use in hazardous areas: Test number PTB | Ex-96.D.2092X |
| Ambient temperature during operation: max. | 60 °C |
|---|
| required front connector | 20-pin |
|---|
| Width | 40 mm |
|---|---|
| Height | 125 mm |
| Depth | 120 mm |
| Weight, approx. | 290 g |
|---|
| ETIM | 8 EC001420 |
|---|---|
| IDEA | 4 3562 |
| UNSPSC | 15 32-15-17-05 |
| CCC-Ex NK / Nippon Kaiji Ky- | okai |
|---|
| Net weight | 0.409 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.909 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | Critical stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for 6ES7331-7RD00-0AB0 is 85389091.
The EAN (GTIN) of 6ES7331-7RD00-0AB0 is 4025515061229.
6ES7331-7RD00-0AB0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.