Part number
6ES7215-1HF40-0XB0
Model no
CPU 1215FC DC/DC/relay
$1,237.86 On request Dispatch — · From TürkiyeGet a Quote
SIMATIC S7-1200

Siemens 6ES7215-1HF40-0XB0 SIMATIC S7-1200 1215FC DC/DC/RLY 14DI/10DO/2AI/2AO Programmable Logic Controller

SIMATIC S7-1200 CPU 1215FC DC/DC/RLY: 14 DI, 10 relay DO 2A, 2 AI, 2 AO, dual PROFINET.

Rated current
2 A
Rated operational voltage
24 V AC
Communication
PROFINET IO Controller/Device, PROFIBUS (via CM), PROFIsafe, OPC UA Server, AS-Interface (via CM)
EAN
4025515082941
Description

About the CPU 1215FC DC/DC/relay

The Siemens 6ES7215-1HF40-0XB0 is a SIMATIC S7-1200 CPU 1215FC DC/DC/RLY, a fail-safe-capable compact controller with 14 digital inputs, 10 relay outputs rated 2 A, 2 analog inputs (0-10 V) and 2 analog outputs (0-20 mA) built in. It runs from 20.4 to 28.8 V DC, stores 250 KB combined program and data memory, and reaches the network through two integrated PROFINET ports.

Certifications & Standards

  • CE
  • UL
  • cULus
  • FM
  • RCM
  • KC
  • Marine

Selection Notes

This relay-output 1215FC keeps the analog I/O of the DC/DC/DC version (2 AI 0-10 V, 2 AO 0-20 mA) but swaps the 10 transistor outputs for 10 relay outputs at 2 A resistive, so it drives small AC or higher-current DC loads directly without external interposing relays. The tradeoff is no 100 kHz pulse-train output, so pick a transistor-output sibling instead when an axis needs PTO stepper/servo control; pick this variant when the output loads are contactors, solenoids, or indicator lamps rather than high-speed pulses.

Specification

Full specification

242 values · Last verified 01 Nov 2026

General information 3

Product type designation CPU 1215FC DC/DC/relay
Firmware version V4.7
Engineering with: Programming package STEP 7 V20 or higher

Supply voltage 7

Rated value (DC): 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Load voltage L+: Rated value (DC) 24 V
Load voltage L+: permissible range, lower limit (DC) 20.4 V
Load voltage L+: permissible range, upper limit (DC) 28.8 V

Input current 4

Current consumption (rated value) 500 mA; CPU only
Current consumption, max. 1 500 mA; CPU with all expansion modules
Inrush current, max. 12 A; at 28.8 V DC
I2t 0.5 A2·s
Show all 242 specifications ↓ Show less ↑228 more values in Identification, Output current, Encoder supply, Power loss, Storage, CPU processing times, CPU-blocks, Data areas and their retentivity, Address area, Hardware configuration, Time of day, Digital inputs, Digital outputs, Analog inputs, Analog outputs, Analog value generation for the inputs, Analog value generation for the outputs, Encoder, Interfaces, 1. Interface, Protocols, Communication functions, Test commissioning functions, Interrupts/diagnostics/status information, Integrated Functions, Potential separation, EMC, Degree and class of protection, Standards, approvals, certificates, Ambient conditions, Configuration, Dimensions, Weights, Logistics.

Identification 10

Part number 6ES7215-1HF40-0XB0
Type designation CPU 1215FC DC/DC/relay
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4025515082941
ETIM class EC000236
eCl@ss 27242207

Output current 1

for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM

Encoder supply 1

24 V encoder supply: 24 V L+ minus 4 V DC min.

Power loss 1

Power loss, typ. 12 W

Storage 6

Work memory: integrated 250 kbyte
Load memory: Integrated 4 Mbyte
Load memory: Plug-in (SIMATIC Memory Card), max. with SIMATIC memory card
Backup: present Yes
Backup: maintenance-free Yes
Backup: without battery Yes

CPU processing times 3

for bit operations, typ. 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction

CPU-blocks 2

Number of elements (total) DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
OB: Number, max. Limited only by RAM for code

Data areas and their retentivity 3

Retentive data area (incl. timers, counters, flags), max. 14 kbyte
Flag: Size, max. 8 kbyte; Size of bit memory address area
Local data: per priority class, max. 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB

Address area 2

Process image: Inputs, adjustable 1 kbyte
Process image: Outputs, adjustable 1 kbyte

Hardware configuration 4

Number of modules per system, max. 3 comm. modules, 1 signal board, 8 signal modules
number of expansion boards (SB, CB, BB) 1
number of signal modules (SM) 8
number of communications modules (CM) 3

Time of day 3

Clock: Hardware clock (real-time) Yes
Clock: Backup time 480 h; Typical
Clock: Deviation per day, max. ±60 s/month at 25 °C

Digital inputs 10

Number of digital inputs 14; Integrated
of which inputs usable for technological functions 6; HSC (High Speed Counting)
Sourcing/sinking input Yes
Number of simultaneously controllable inputs all mounting positions: up to 40 °C, max. 14
Input voltage: Rated value (DC) 24 V
Input voltage: for signal "0" 5 V DC at 1 mA
Input voltage: for signal "1" 15 V DC at 2.5 mA
Input delay (for rated value of input voltage) for standard inputs: parameterizable Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
Cable length: shielded, max. 500 m; 50 m for technological functions
Cable length: unshielded, max. 300 m; for technological functions: No

Digital outputs 9

Number of digital outputs 10; Relays
Switching capacity of the outputs: with resistive load, max. 2 A
Switching capacity of the outputs: on lamp load, max. 30 W with DC, 200 W with AC
Output delay with resistive load: "0" to "1", max. 10 ms; max.
Output delay with resistive load: "1" to "0", max. 10 ms; max.
Relay outputs: Number of relay outputs 10
Relay outputs: Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000
Cable length: shielded, max. 500 m
Cable length: unshielded, max. 150 m

Analog inputs 5

Number of analog inputs 2
Input ranges: Voltage Yes
Input ranges (rated values), voltages: 0 to +10 V Yes
Input ranges (rated values), voltages: Input resistance (0 to 10 V) ≥100k ohms
Cable length: shielded, max. 100 m; twisted and shielded

Analog outputs 2

Number of analog outputs 2
Output ranges, current: 0 to 20 mA Yes

Analog value generation for the inputs 3

Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. 10 bit
Integration and conversion time/resolution per channel: Integration time, parameterizable Yes
Integration and conversion time/resolution per channel: Conversion time (per channel) 625 µs

Analog value generation for the outputs 1

Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. 10 bit

Encoder 1

Connectable encoders: 2-wire sensor Yes

Interfaces 1

Number of PROFINET interfaces 1

1. Interface 35

Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface types: RJ 45 (Ethernet) Yes
Interface types: Number of ports 2
Interface types: integrated switch Yes
Protocols: PROFINET IO Controller Yes
Protocols: PROFINET IO Device Yes
Protocols: SIMATIC communication Yes
Protocols: Open IE communication Yes; Optionally also encrypted
Protocols: Web server Yes
Protocols: Media redundancy Yes
PROFINET IO Controller: Transmission rate, max. Services 100 Mbit/s
PROFINET IO Controller: PG/OP communication Yes; encryption with TLS V1.3 pre-selected
PROFINET IO Controller: Isochronous mode No
PROFINET IO Controller: IRT No
PROFINET IO Controller: PROFIenergy No
PROFINET IO Controller: Prioritized startup Yes
PROFINET IO Controller: Number of IO devices with prioritized startup, max. 16
PROFINET IO Controller: Number of connectable IO Devices, max. 16
PROFINET IO Controller: Number of connectable IO Devices for RT, max. 16
PROFINET IO Controller: of which in line, max. 16
PROFINET IO Controller: Number of IO Devices that can be simultaneously activated/deactivated, max. 8
PROFINET IO Controller: Updating time The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
PROFINET IO Device Services: PG/OP communication Yes; encryption with TLS V1.3 pre-selected
PROFINET IO Device Services: Isochronous mode No
PROFINET IO Device Services: IRT No
PROFINET IO Device Services: Dynamic Frame Packing (DFP) No
PROFINET IO Device Services: PROFIenergy Yes
PROFINET IO Device Services: Prioritized startup Yes
PROFINET IO Device Services: Shared device Yes
PROFINET IO Device Services: Number of IO Controllers with shared device, max. 2
PROFINET IO Device Services: Asset management record Yes

Protocols 35

PROFINET IO Yes
PROFIsafe Yes
PROFIBUS Yes; CM 1243-5 (master) or CM 1242-5 (slave) required
OPC UA Yes; OPC UA Server
AS-Interface Yes; CM 1243-2 required
Protocols (Ethernet): TCP/IP Yes
Protocols (Ethernet): DHCP No
Protocols (Ethernet): SNMP Yes
Protocols (Ethernet): DCP Yes
Protocols (Ethernet): LLDP Yes
Redundancy mode: PROFINET system redundancy (S2) No
Redundancy mode: PROFINET system redundancy (R1) Media redundancy No
Redundancy mode: MRP Yes; as MRP redundancy manager and/or MRP client
Redundancy mode: MRP interconnection, supported No
Redundancy mode: MRPD No
SIMATIC communication: S7 routing Yes
Open IE communication: TCP/IP Yes
Open IE communication: Data length, max. 8 kbyte
Open IE communication: ISO-on-TCP (RFC1006) Yes
Open IE communication: UDP Yes
Web server: supported Yes
Web server: User-defined websites Yes
OPC UA: Runtime license required Yes; "Basic" license required
OPC UA: OPC UA Server Yes; data access (read, write, subscribe), method call, runtime license required
OPC UA: Application authentication Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
OPC UA: User authentication "anonymous" or by user name & password
OPC UA: Number of sessions, max. 10
OPC UA: Number of subscriptions per session, max. 5
OPC UA: Sampling interval, min. 100 ms
OPC UA: Publishing interval, min. 200 ms
OPC UA: Number of server methods, max. 20
OPC UA: Number of monitored items, recommended max. 1 000
OPC UA: Number of server interfaces, max. 2
OPC UA: Number of nodes for user-defined server interfaces, max. 2 000
Further protocols: MODBUS Yes

Communication functions 5

S7 communication: supported Yes
S7 communication: as server Yes
S7 communication: as client Yes
S7 communication: User data per job, max. See online help (S7 communication, user data size)
Number of connections: overall PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 68 max

Test commissioning functions 6

Status/control: Status/control variable Yes
Status/control: Variables inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
Forcing: Forcing Yes; peripheral inputs/outputs (without fail-safe)
Diagnostic buffer: present Yes
Traces: Number of configurable Traces 2
Traces: Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information 3

Diagnostics indication LED: RUN/STOP LED Yes
Diagnostics indication LED: ERROR LED Yes
Diagnostics indication LED: MAINT LED Yes

Integrated Functions 8

Counter: Number of counters 6
Counter: Counting frequency, max. 100 kHz
Frequency measurement Yes
controlled positioning Yes
Number of position-controlled positioning axes, max. 8
Number of positioning axes via pulse-direction interface Up to 4 with SB 1222
PID controller Yes
Number of alarm inputs 4

Potential separation 5

Potential separation digital inputs: Potential separation digital inputs 500 V AC for 1 minute
Potential separation digital inputs: between the channels, in groups of 1
Potential separation digital outputs: Potential separation digital outputs Relays
Potential separation digital outputs: between the channels No
Potential separation digital outputs: between the channels, in groups of 2

EMC 5

Interference immunity against discharge of static electricity: Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes
Interference immunity to cable-borne interference: Interference immunity on supply lines acc. to IEC 61000-4-4 Yes
Interference immunity against voltage surge: Interference immunity on supply lines acc. to IEC 61000-4-5 Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields: Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Yes
Emission of radio interference acc. to EN 55 011: Limit class A, for use in industrial areas Yes; Group 1

Degree and class of protection 1

IP degree of protection IP20

Standards, approvals, certificates 15

Siemens Eco Profile (SEP) Siemens EcoTech
CE mark Yes
UL approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Marine approval Yes
Ecological footprint: environmental product declaration Global warming potential Yes; type II acc. to ISO 14021
Ecological footprint: global warming potential, (total) [CO2 eq] 106 kg
Ecological footprint: global warming potential, (during production) [CO2 eq] 18.5 kg
Ecological footprint: global warming potential, (during operation) [CO2 eq] 88.2 kg
Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] -1.1 kg
Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 PLe
Highest safety class achievable in safety mode: SIL acc. to IEC 61508 SIL 3

Ambient conditions 17

Free fall: Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation: min. 0 °C
Ambient temperature during operation: max. 55 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical
Ambient temperature during operation: horizontal installation, min. 0 °C
Ambient temperature during operation: vertical installation, min. 0 °C
Ambient temperature during storage/transportation: min. -40 °C
Ambient temperature during storage/transportation: max. 70 °C
Air pressure acc. to IEC 60068-2-13: Operation, min. 795 hPa
Air pressure acc. to IEC 60068-2-13: Operation, max. 1 080 hPa
Air pressure acc. to IEC 60068-2-13: Storage/transport, min. 660 hPa
Air pressure acc. to IEC 60068-2-13: Storage/transport, max. 1 080 hPa
Altitude during operation relating to sea level: Installation altitude, min. -1 000 m
Relative humidity: Operation, max. 95 %; no condensation
Vibrations: Vibration resistance during operation acc. to IEC 60068-2-6 2 g (m/s2) wall mounting, 1 g (m/s2) DIN rail
Vibrations: Operation, tested according to IEC 60068-2-6 Yes
Shock testing: tested according to IEC 60068-2-27 Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Pollutant concentrations: SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60 % condensation-free

Configuration 15

Programming Programming language: LAD Yes; incl. failsafe
Programming Programming language: FBD Yes; incl. failsafe
Programming Programming language: SCL Yes
Know-how protection: User program protection/password protection Yes
Know-how protection: Copy protection Yes
Know-how protection: Block protection Yes
Access protection: protection of confidential configuration data Yes
Access protection: Protection level: Write protection Yes
Access protection: Protection level: Read/write protection Yes
Access protection: Protection level: Complete protection Yes
Access protection: User administration Yes; device-wide
Access protection: Number of users 42
Access protection: Number of groups 14
Access protection: Number of roles 20
Cycle time monitoring: can be set Yes

Dimensions 3

Width 130 mm
Height 100 mm
Depth 75 mm

Weights 1

Weight, approx. 585 g

Logistics 6

Net weight 0.436 kg
Country of origin CN
Shipping weight 0.936 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 01 Nov 2026

Documents

Documents for 6ES7215-1HF40-0XB0

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CE mark
  • UL approval
  • cULus
  • FM approval
  • RCM (formerly C-TICK)
  • KC approval
  • Marine approval
Quick answers

Questions about the CPU 1215FC DC/DC/relay

What is the rated current of CPU 1215FC DC/DC/relay?

The rated current of CPU 1215FC DC/DC/relay is 2 A.

Which supply voltage is CPU 1215FC DC/DC/relay rated for?

The rated operational voltage of CPU 1215FC DC/DC/relay is 24 V AC.

What is the HS code of CPU 1215FC DC/DC/relay for customs?

The tariff (HS) code on file for CPU 1215FC DC/DC/relay is 85371091.

What is the EAN of CPU 1215FC DC/DC/relay?

The EAN (GTIN) of CPU 1215FC DC/DC/relay is 4025515082941.

Where does CPU 1215FC DC/DC/relay ship from, and how fast?

CPU 1215FC DC/DC/relay ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for PLC & controllers

All guides for PLC & controllers
Reviews

Customer reviews

Series

Siemens SIMATIC S7-1200

Brand
Siemens
Series
SIMATIC S7-1200
$1,237.86 On request
Get a Quote
Quote

Get a Quote

CPU 1215FC DC/DC/relay

Genuine parts

Genuine, factory-sealed parts

Siemens · 6ES7215-1HF40-0XB0

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart