- Home
- All Products
- Siemens 6ES7212-1AF40-0XB0 SIMATIC S7-1200 CPU 1212FC DC/DC/DC 8DI/6DO/2AI Programmable Logic Controller Siemens 6ES7212-1AF40-0XB0 SIMATIC S7-1200 CPU 1212FC DC/DC/DC 8DI/6DO/2AI Programmable Logic Controller
Siemens 6ES7212-1AF40-0XB0 SIMATIC S7-1200 CPU 1212FC DC/DC/DC 8DI/6DO/2AI Programmable Logic Controller
Get Quote
- Description
Siemens 6ES7212-1AF40-0XB0 is a SIMATIC S7-1200F CPU 1212 FC compact programmable logic controller with a DC/DC/DC power scheme, integrated 8 DI, 6 DO, and 2 AI onboard, 150 KB of work memory, and a PROFINET interface offering IO controller/device functionality plus PROFIsafe support for fail-safe machine applications built into a small hardware footprint.
Technical Specifications
| Order No. (MLFB) | 6ES7212-1AF40-0XB0 |
| Brand | Siemens |
| Series | SIMATIC S7-1200 |
| Product Type Designation | CPU 1212FC DC/DC/DC |
| Firmware Version | V4.7 |
| Programming Package | STEP 7 V20 or higher |
| Supply Voltage (DC), rated | 24 V |
| Supply Voltage (DC), range | 20.4 V to 28.8 V |
| Current Consumption, rated (CPU only) | 400 mA |
| Current Consumption, max. (with expansions) | 1,200 mA |
| Power Loss, typ. | 9 W |
| Work Memory, integrated | 150 kbyte |
| Load Memory, integrated | 2 Mbyte |
| Digital Inputs | 8; 6 usable for HSC |
| Digital Outputs | 6; 4 high-speed 100 kHz PTO |
| Analog Inputs | 2; 0 to 10 V |
| Output Current, rated (signal 1) | 0.5 A |
| Interfaces, PROFINET | 1; RJ45, isolated |
| PROFINET IO Controller Transmission Rate, max. | 100 Mbit/s |
| Protocols | PROFINET IO Controller/Device, PROFIsafe, OPC UA Server, Open IE Communication |
| Number of Modules per System, max. | 3 comm. modules, 1 signal board, 2 signal modules |
| Clock Backup Time | 480 h, typical |
Certifications & Standards
- CE
- UL
- cULus
- FM
- RCM
- KC
- Marine
Selection Notes
This CPU 1212FC is the compact fail-safe entry point in the S7-1200 line: 8 DI/6 DO/2 AI are fixed onboard, and expansion is capped at 3 communication modules, 1 signal board, and 2 signal modules, so it fits small stand-alone safety machines rather than lines needing more I/O headroom. Choose the 1212FC specifically when PROFIsafe fail-safe functions (light curtains, E-stop circuits) are required within this small footprint and 150 KB of work memory is sufficient; applications needing more program memory or expansion slots should move to a larger FC CPU in the same series. Native OPC UA server support lets it publish process data to SCADA/MES layers without an added communication processor.
Applications
Fail-safe machine control such as light-curtain or E-stop circuits via PROFIsafe, small packaging or conveyor cells needing integrated analog inputs for basic process monitoring, and PROFINET-based cells requiring native IO controller function without additional communication modules.