Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7155-6MU01-0CN0 (IM 155-6 MF HF) is a MultiFieldbus interface module for the SIMATIC ET 200SP I/O system, supporting PROFINET IO, EtherNet/IP, and Modbus TCP on the same hardware. It manages up to 64 ET 200SP modules and 16 ET 200AL modules per station, with PROFINET S2 system redundancy and multi hot-swap for module replacement under power.
The MultiFieldbus design runs PROFINET IO, EtherNet/IP, or Modbus TCP from the same station without swapping hardware, which matters when a line mixes Siemens PROFINET cells with EtherNet/IP robots or PLCs from other vendors. PROFINET S2 system redundancy with multi hot-swap supports lines where a station fault cannot stop production, since modules can be replaced while the station stays powered. The 64-module / 16 ET 200AL ceiling and 1,440-byte address space per station set the scaling limit before a second station is required.
Distributed I/O stations on machines or lines that must serve mixed-fieldbus plant floors — PROFINET-based Siemens controllers alongside EtherNet/IP PLCs or Modbus TCP SCADA — from a single ET 200SP station. The S2 redundancy and hot-swap capability suit continuous-process or high-uptime conveyor lines where I/O station downtime during module replacement is not acceptable.
| Product type designation | IM 155-6 MF HF |
|---|---|
| Firmware version | V6.4.1 |
| FW update possible | Yes |
| Vendor identification (VendorID) | 002 AH |
| Device identifier (DeviceID) | 0313 H |
| Manufacturer ID according to ODVA (VendorID) | 0x04E3 |
| Device ID according to ODVA (Product code) | 0FA2H |
| Product function: I&M data | Yes; I&M0 to I&M4 |
| Product function: Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| Product function: Isochronous mode | Yes |
| Product function: IRT | Yes |
| Product function: Tool changer | Yes; Docking station and docking unit |
| Product function: Local coupling, IO data | Yes |
| Product function: Number of coupling modules | 6; 1x output + max. 5x input |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V20 |
| Engineering with: STEP 7 configurable/integrated from version | V5.7 SP3 |
| Engineering with: PROFINET from GSD version/GSD revision | GSDML V2.45 |
| Engineering with: Multi Fieldbus Configuration Tool (MFCT) | V1.5.2.0 or higher |
| via dataset | Yes |
|---|
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 10 ms |
| Part number | 6ES7155-6MU01-0CN0 |
|---|---|
| Type designation | IM 155-6 MF HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4047623412991 |
| ETIM class | EC001604 |
| eCl@ss | 27242608 |
| Current consumption (rated value) | 550 mA |
|---|---|
| Current consumption, max. | 650 mA |
| Inrush current, max. | 1 A |
| I2t | 0.05 A2·s |
| Power loss, typ. | 2 W |
|---|
| Address space per module: Address space per module, max. | 288 byte; For input and output data respectively |
|---|---|
| Address space per station: Address space per station, max. | 1 440 byte |
| Rack: Quantity of operable ET 200SP modules, max. | 64 |
|---|---|
| Rack: Quantity of operable ET 200AL modules, max. | 16 |
| Submodules: Number of submodules per station, max. | 256 |
| Transmission procedure | 100BASE-TX |
|---|---|
| Number of PROFINET interfaces | 1; 2 ports (switch) |
| Interface types: RJ 45 (Ethernet) | Yes; with BusAdapter |
|---|---|
| Interface types: Number of ports | 2; with BusAdapter |
| Interface types: integrated switch | Yes |
| Interface types: BusAdapter (PROFINET) | Yes; BA 2x RJ45, BA 2x M12, BA 2x FC |
| Protocols: PROFINET IO Device | Yes |
| Protocols: Open IE communication | Yes |
| Protocols: Media redundancy | Yes; PROFINET MRP client |
| PROFINET IO Device Services: IRT | Yes; 250 µs to 4 ms in 125 µs frame |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Device Services: Fast Forwarding | Yes |
| PROFINET IO Device Services: Fragmentation | Yes |
| PROFINET IO Device Services: PROFIenergy | Yes |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 14; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| RJ 45 (Ethernet): Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
|---|---|
| RJ 45 (Ethernet): 100 Mbps | Yes |
| RJ 45 (Ethernet): Autonegotiation | Yes |
| RJ 45 (Ethernet): Autocrossing | Yes |
| Supports protocol for PROFINET IO | Yes |
|---|---|
| PROFIsafe | Yes |
| PROFIBUS | No |
| EtherNet/IP | Yes |
| Modbus TCP | Yes |
| Number of connections: Number of MtM communication relationships/connections, max. | 16 |
| Redundancy mode: PROFINET system redundancy (S2) | Yes; NAP S2 |
| Redundancy mode: PROFINET system redundancy (R1) | No |
| Redundancy mode: H-Sync forwarding Media redundancy | Yes |
| Redundancy mode: MRP | Yes |
| Redundancy mode: MRPD | Yes |
| EtherNet/IP Services: CIP Implicit Messaging | Yes |
| EtherNet/IP Services: CIP Explicit Messaging | Yes |
| EtherNet/IP Services: CIP Safety | No |
| EtherNet/IP Services: Configuration control via Explicit Messaging | No |
| EtherNet/IP Services: Shared device | Yes; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| EtherNet/IP Services: Number of scanners with shared device, max. Updating times | 2 |
| EtherNet/IP Services: Requested Packet Interval (RPI) Address area | 2 ms |
| EtherNet/IP Services: Address space per module, max. | 288 byte; (246 byte outputs / 288 byte inputs) |
| EtherNet/IP Services: ForwardOpen (Class1 & 32 bit Header) | 500 byte; (246 byte outputs / 500 byte inputs) |
| EtherNet/IP Services: LargeForwardOpen (Class3) Connections | 4 002 byte |
| EtherNet/IP Services: Number of rack connections | 2 |
| Modbus TCP Services: read coils (code=1) | Yes |
| Modbus TCP Services: read discrete inputs (code=2) | Yes |
| Modbus TCP Services: Read Holding Registers (Code=3) | Yes |
| Modbus TCP Services: Read Input Register (Code=4) | Yes |
| Modbus TCP Services: write single coil (code=5) | Yes |
| Modbus TCP Services: Write Single Register (Code=6) | Yes |
| Modbus TCP Services: write multiple coils (code=15) | Yes |
| Modbus TCP Services: Write Multiple Registers (Code=16) | Yes |
| Modbus TCP Services: Read/Write Multiple Registers (Code=23) | Yes |
| Modbus TCP Services: Parameter change by master | Yes |
| Modbus TCP Services: Modbus TCP Security Protocol Address space per station | No |
| Modbus TCP Services: Address space per station, max. | 500 byte; (246 byte outputs / 500 byte inputs) |
| Modbus TCP Services: Access-consistent address space Updating time | 250 byte; (246 byte outputs / 250 byte inputs) |
| Modbus TCP Services: I/O request interval Connections | 2 ms |
| Modbus TCP Services: number of connections per device | 9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info) |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: ARP | Yes |
| Open IE communication: IGMP | Yes |
| Open IE communication: Multicast | Yes |
| Open IE communication: Broadcast | Yes |
| Open IE communication: IPv4 | Yes |
| Open IE communication: IPv6 | No |
| Equidistance | Yes |
|---|---|
| shortest clock pulse | 250 µs |
| max. cycle | 4 ms |
| Bus cycle time (TDP), min. | 250 µs |
| Jitter, max. | 1 µs |
| Status indicator | Yes |
|---|---|
| Alarms | Yes |
| Diagnostics function | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: NS LED | Yes; green/red LED |
| Diagnostics indication LED: MS LED | Yes; green/red LED |
| Diagnostics indication LED: IO LED | Yes; red-green-yellow LED |
| Diagnostics indication LED: Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter |
| between backplane bus and electronics | No |
|---|---|
| between PROFINET and all other circuits | Yes; 1500 V AC (type test) |
| between supply and all other circuits | No |
| between different circuits | Safety extra low voltage SELV |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Network loading class | 3 |
|---|
| PROFINET Security Class | 1 |
|---|---|
| signed firmware update | Yes |
| Secure Boot | No |
| safely removing data | Yes |
| data integrity | Yes |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; No condensation |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; No condensation |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual |
| ET-Connection: via BU/BA Send | Yes; + 16 ET 200AL modules |
|---|
| Strain relief | Yes; Optional |
|---|
| Width | 50 mm |
|---|---|
| Height | 117 mm |
| Depth | 74 mm |
| Weight, approx. | 120 g; without BusAdapter |
|---|
| Net weight | 0.173 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.673 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of IM 155-6 MF HF is 0.55 A.
The rated operational voltage of IM 155-6 MF HF is 24 V AC.
The tariff (HS) code on file for IM 155-6 MF HF is 85176200.
The EAN (GTIN) of IM 155-6 MF HF is 4047623412991.
IM 155-6 MF HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.