The Siemens 6ES7155-6AR01-0AN0 is a SIMATIC ET 200SP IM 155-6 PN Basic PROFINET interface module that heads a station of up to 16 ET 200SP I/O modules over two integrated RJ45 ports. It supports PROFINET IRT down to 1ms cycle time, MRP media redundancy, hot swapping, and runs on 24V DC drawing 200mA typical.
The two-port integrated switch and MRP/MRPD support let this IM 155-6 PN Basic head unit sit in a ring topology for bumpless recovery from a single cable break — choose a High Feature or High Speed IM variant instead if the application needs isochronous PROFINET below the 1ms cycle time or more than the 6 local coupling channels this Basic module offers. Hot-swap support (multi-hot swap) means individual I/O modules downstream can be replaced without powering down the whole station, which matters for stations with 16 modules where a single fault shouldn't force a full station stop. PROFINET Security Class 1 with signed firmware updates is the baseline security level in the ET 200SP interface-module range — confirm the security class needed at commissioning before assuming this Basic variant meets a higher-class network security policy.
Heads a decentralized ET 200SP I/O station on a PROFINET line — machine-local or remote I/O drops in packaging, material handling, and process automation where up to 16 I/O modules and ring-redundant PROFINET are needed.
| Product type designation | IM 155-6 PN BA |
|---|---|
| Firmware version | V6.4.0 |
| FW update possible | Yes |
| Vendor identification (VendorID) | 0x002A |
| Device identifier (DeviceID) | 0x0313 |
| Product function: I&M data | Yes; I&M0 to I&M4 |
| Product function: Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| Product function: Isochronous mode | No |
| Product function: IRT | Yes |
| Product function: Local coupling, IO data | Yes |
| Product function: Number of coupling modules | 6; 1x output + max. 5x input |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V20 |
| Engineering with: STEP 7 configurable/integrated from version | V5.7 SP3 |
| Engineering with: PROFINET from GSD version/GSD revision | GSDML V2.45 |
| via dataset | Yes |
|---|
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 5 ms |
| Part number | 6ES7155-6AR01-0AN0 |
|---|---|
| Type designation | IM 155-6 PN BA |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4047623416012 |
| ETIM class | EC001604 |
| eCl@ss | 27242608 |
| Current consumption (rated value) | 200 mA |
|---|---|
| Current consumption, max. | 300 mA |
| Inrush current, max. | 1 A |
| I2t | 0.05 A2·s |
| Power loss, typ. | 1.8 W |
|---|
| Address space per module: Address space per module, max. | 128 byte; For input and output data respectively |
|---|---|
| Address space per station: Address space per station, max. | 128 byte |
| Rack: Quantity of operable ET 200SP modules, max. | 16 |
|---|---|
| Rack: Quantity of operable ET 200AL modules, max. | 0 |
| Submodules: Number of submodules per station, max. | 256 |
| Transmission procedure | 100BASE-TX |
|---|---|
| Number of PROFINET interfaces | 1; 2 ports (switch) |
| Interface types: RJ 45 (Ethernet) | Yes; 2 integrated RJ45 ports |
|---|---|
| Interface types: Number of ports | 2; integrated RJ45 ports |
| Interface types: integrated switch | Yes |
| Interface types: BusAdapter (PROFINET) | No |
| Protocols: PROFINET IO Device | Yes |
| Protocols: Open IE communication | Yes |
| Protocols: Media redundancy | Yes; PROFINET MRP client |
| PROFINET IO Device Services: IRT | Yes; 1 ms to 4 ms at an interval of 125 µs |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Device Services: Fast Forwarding | Yes |
| PROFINET IO Device Services: Fragmentation | Yes |
| PROFINET IO Device Services: PROFIenergy | Yes |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | No |
| RJ 45 (Ethernet): Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
|---|---|
| RJ 45 (Ethernet): 100 Mbps | Yes |
| RJ 45 (Ethernet): Autonegotiation | Yes |
| RJ 45 (Ethernet): Autocrossing | Yes |
| Supports protocol for PROFINET IO | Yes |
|---|---|
| PROFIsafe | No |
| PROFIBUS | No |
| EtherNet/IP | No |
| Modbus TCP | No |
| Redundancy mode: PROFINET system redundancy (S2) | No |
| Redundancy mode: PROFINET system redundancy (R1) Media redundancy | No |
| Redundancy mode: MRP | Yes |
| Redundancy mode: MRPD | Yes |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: ARP | Yes |
| Open IE communication: IGMP | Yes |
| Open IE communication: Multicast | Yes |
| Open IE communication: Broadcast | Yes |
| Open IE communication: IPv4 | Yes |
| Open IE communication: IPv6 | No |
| Status indicator | Yes |
|---|---|
| Alarms | Yes |
| Diagnostics function | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: Connection display LINK TX/RX | Yes; 2x green LED |
| between backplane bus and electronics | No |
|---|---|
| between PROFINET and all other circuits | Yes; 1500 V AC (type test) |
| between supply and all other circuits | No |
| between different circuits | Safety extra low voltage SELV |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Network loading class | 3 |
|---|
| PROFINET Security Class | 1 |
|---|---|
| signed firmware update | Yes |
| Secure Boot | No |
| securely removing data | Yes |
| data integrity | Yes |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; No condensation |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; No condensation |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| ET-Connection: via BU/BA Send | No |
|---|
| Strain relief | No |
|---|
| Width | 35 mm |
|---|---|
| Height | 117 mm |
| Depth | 74 mm |
| Weight, approx. | 125 g |
|---|
| Net weight | 0.16 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.66 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of IM 155-6 PN BA is 24 V AC.
The tariff (HS) code on file for IM 155-6 PN BA is 85176200.
The EAN (GTIN) of IM 155-6 PN BA is 4047623416012.
IM 155-6 PN BA ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.