The Siemens 6ES7155-6AA02-0BN0 is a SIMATIC ET 200SP PROFINET interface module (IM 155-6 PN ST) supplied as a bundle with a BA 2xRJ45 bus adapter and server module, supporting up to 32 ET 200SP I/O modules plus 16 ET 200AL modules per station. It provides IRT communication down to 1 ms cycle time and PROFIsafe Security Class 1.
ST marks the Standard-performance interface variant — pick it when the station's I/O count and cycle-time needs stay within IRT 1-4 ms and 32 modules, and move to an HF interface only if the application needs faster isochronous cycles or a larger station. The bundled BA 2xRJ45 gives a switched two-port connection for line-topology PROFINET wiring without ordering the bus adapter separately, and PROFIsafe Security Class 1 support means the same station can host F-modules for safety I/O alongside standard I/O.
Building modular PROFINET remote I/O stations that mix standard and fail-safe I/O modules on a single ET 200SP rack, in line or ring (MRP) network topologies.
| Product type designation | IM 155-6 PN ST incl. BA 2x RJ45 and server module |
|---|---|
| Firmware version | V6.4.0 |
| FW update possible | Yes |
| Vendor identification (VendorID) | 002 AH |
| Device identifier (DeviceID) | 0313 H |
| Manufacturer ID according to ODVA (VendorID) | 04E3H |
| Device ID according to ODVA (Product code) | 0FA2H |
| Product function: I&M data | Yes; I&M0 to I&M4 |
| Product function: Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| Product function: Isochronous mode | No |
| Product function: IRT | Yes |
| Product function: Local coupling, IO data | Yes |
| Product function: Number of coupling modules | 6; 1x output + max. 5x input |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V20 |
| Engineering with: STEP 7 configurable/integrated from version | V5.7 SP3 |
| Engineering with: PROFINET from GSD version/GSD revision | GSDML V2.45 |
| via dataset | Yes |
|---|
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Mains buffering: Mains/voltage failure stored energy time | 10 ms |
| Part number | 6ES7155-6AA02-0BN0 |
|---|---|
| Type designation | IM 155-6 PN ST incl. BA 2x RJ45 and server module |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4047623413059 |
| ETIM class | EC001604 |
| eCl@ss | 27242608 |
| Current consumption (rated value) | 350 mA |
|---|---|
| Current consumption, max. | 450 mA |
| Inrush current, max. | 1 A |
| I2t | 0.05 A2·s |
| Power loss, typ. | 1.8 W |
|---|
| Address space per module: Address space per module, max. | 288 byte; For input and output data respectively |
|---|---|
| Address space per station: Address space per station, max. | 1 440 byte |
| Rack: Quantity of operable ET 200SP modules, max. | 32 |
|---|---|
| Rack: Quantity of operable ET 200AL modules, max. | 16 |
| Submodules: Number of submodules per station, max. | 256 |
| Transmission procedure | 100BASE-TX |
|---|---|
| Number of PROFINET interfaces | 1; 2 ports (switch) |
| Interface types: RJ 45 (Ethernet) | Yes; with BusAdapter |
|---|---|
| Interface types: Number of ports | 2; with BusAdapter |
| Interface types: integrated switch | Yes |
| Interface types: BusAdapter (PROFINET) | Yes; BA 2x RJ45, BA 2x FC, BA 2x M12 |
| Protocols: PROFINET IO Device | Yes |
| Protocols: Open IE communication | Yes |
| Protocols: Media redundancy | Yes; PROFINET MRP client |
| PROFINET IO Device Services: IRT | Yes; 1 ms to 4 ms at an interval of 125 µs |
| PROFINET IO Device Services: Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Device Services: Fast Forwarding | Yes |
| PROFINET IO Device Services: Fragmentation | Yes |
| PROFINET IO Device Services: PROFIenergy | Yes |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 4 |
| RJ 45 (Ethernet): Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
|---|---|
| RJ 45 (Ethernet): 100 Mbps | Yes |
| RJ 45 (Ethernet): Autonegotiation | Yes |
| RJ 45 (Ethernet): Autocrossing | Yes |
| Supports protocol for PROFINET IO | Yes |
|---|---|
| PROFIsafe | Yes |
| PROFIBUS | No |
| EtherNet/IP | No |
| Modbus TCP | No |
| Redundancy mode: PROFINET system redundancy (S2) | No |
| Redundancy mode: PROFINET system redundancy (R1) Media redundancy | No |
| Redundancy mode: MRP | Yes |
| Redundancy mode: MRPD | Yes |
| Open IE communication: TCP/IP | Yes |
| Open IE communication: UDP | Yes |
| Open IE communication: SNMP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: ARP | Yes |
| Open IE communication: IGMP | Yes |
| Open IE communication: Multicast | Yes |
| Open IE communication: Broadcast | Yes |
| Open IE communication: IPv4 | Yes |
| Open IE communication: IPv6 | No |
| Status indicator | Yes |
|---|---|
| Alarms | Yes |
| Diagnostics function | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter |
| between backplane bus and electronics | No |
|---|---|
| between PROFINET and all other circuits | Yes; 1500 V AC (type test) |
| between supply and all other circuits | No |
| between different circuits | Safety extra low voltage SELV |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Network loading class | 3 |
|---|
| PROFINET Security Class | 1 |
|---|---|
| signed firmware update | Yes |
| Secure Boot | No |
| securely removing data | Yes |
| data integrity | Yes |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; No condensation |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; No condensation |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual |
| Absolute humidity: dew point, min. | -60 °C; suitable for dry room applications |
| ET-Connection: via BU/BA Send | Yes; + 16 ET 200AL modules |
|---|
| Strain relief | Yes; Optional |
|---|
| Width | 50 mm |
|---|---|
| Height | 117 mm |
| Depth | 74 mm |
| Weight, approx. | 120 g; without BusAdapter |
|---|
| eClass | 8 27-24-26-08 |
|---|---|
| ETIM | 10 EC001604 |
| Net weight | 0.214 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.714 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of IM 155-6 PN ST incl. BA 2x RJ45 and server module is 24 V AC.
The tariff (HS) code on file for IM 155-6 PN ST incl. BA 2x RJ45 and server module is 85176200.
The EAN (GTIN) of IM 155-6 PN ST incl. BA 2x RJ45 and server module is 4047623413059.
IM 155-6 PN ST incl. BA 2x RJ45 and server module ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.