Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7147-4JD00-0AB0 is a SIMATIC ET 200pro EM 4 IO-Link HF electronic module with 4 IO-Link master ports (protocol 1.0/1.1, up to 230.4 kBaud) that can also run as standard digital inputs or outputs. It supports channel-level wire-break and short-circuit diagnostics, draws 40 mA from the 24 V DC supply, and needs the connection module IO 6ES7194-4CA20-0AA0, sold separately.
Each of the 4 ports runs as a full IO-Link master, protocol 1.0/1.1, up to 230.4 kBaud, or drops back to a plain digital input/output at up to 100 mA, so the module covers a station where only some connected devices are IO-Link-capable. 32 bytes of process data per port and 2 kbyte of parameter memory per port support device-parameter backup and restore via the S7-PCT tool or the LIOLink_Master function block for master backup. The 0 degC to 55 degC operating range and channel-level wire-break/short-circuit diagnostics fit panel or cabinet-adjacent mounting rather than unheated outdoor sites.
Fits mixed IO-Link sensor/actuator points and standard 24 V digital I/O on the same ET 200pro DP station, with parameter backup and restore for tool or fixture changeover.
| HW functional status | FS04 |
|---|---|
| Firmware version | V1.2.5 |
| FW update possible | Yes |
| Product function: Isochronous mode | No |
| Operating mode: IO-Link | Yes |
| Operating mode: DI | Yes |
| Operating mode: DQ | Yes; max. 100 mA |
| Rated value (DC) | 24 V |
|---|---|
| Reverse polarity protection | Yes |
| Load voltage 2L+: Rated value (DC) | 24 V |
| Load voltage 2L+: Short-circuit protection | Yes |
| Load voltage 2L+: Reverse polarity protection | Yes; against destruction; load increasing |
| from supply voltage 1L+, max. | 40 mA |
|---|---|
| from load voltage 2L+ (without load), max. | 20 mA |
| from backplane bus 3.3 V DC, max. | 20 mA |
| Part number | 6ES7147-4JD00-0AB0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623406495 |
| ETIM class | EC001604 |
| eCl@ss | 27242608 |
| Number of outputs | 4 |
|---|---|
| Short-circuit protection | Yes; per module, electronic |
| Output current: up to 55 °C, max. | 2 A |
| Power loss, typ. | 2.6 W |
|---|
| Number of ports | 4 |
|---|---|
| of which simultaneously controllable | 4 |
| IO-Link protocol 1.0 | Yes |
| IO-Link protocol 1.1 | Yes |
| Transmission rate | 4.8 kBaud (COM1); 38.4 kBaud (COM2), 230.4 kBaud (COM3) |
| Size of process data, input per port | 32 byte |
| Size of process data, input per module | 32 byte |
| Size of process data, output per port | 32 byte |
| Size of process data, output per module | 32 byte |
| Memory size for device parameter | 2 kbyte; for each port |
| Master backup | possible with LIOLink_Master function block |
| Configuration without S7-PCT | Possible; autostart/manual function |
| Cable length unshielded, max. | 20 m |
| Operating modes: IO-Link | Yes |
| Operating modes: DI | Yes |
| Operating modes: DQ | Yes; max. 100 mA |
| Connection of IO-Link devices: Port type A | Yes; via 3-core cable |
| Connection of IO-Link devices: Port type B | Yes; Additional device supply: for X1 and X2 max. 2 A in total, for X3 and X4 max. 2 A in total |
| Diagnostics function | Yes |
|---|---|
| Alarms: Diagnostic alarm | Yes |
| Diagnoses: Diagnostic information readable | Yes |
| Diagnoses: Wire break | Yes; channel by channel |
| Diagnoses: Short-circuit | Yes; channel by channel |
| Diagnostics indication LED: Channel status display | Yes; One green LED for channel status Qn (SIO mode) and port status IO-Ln (IO-Link mode) |
| Diagnostics indication LED: Group error SF (red) | Yes |
| Diagnostics indication LED: Channel fault indicator F (red) | Yes; combined with the IO-Link port status |
| between the load voltages | Yes |
|---|---|
| between backplane bus and all other circuit components | Yes |
| Potential separation channels: between the channels | No |
| Isolation tested with | 707 V DC (type test) |
|---|
| Suitable for safety-related tripping of standard modules | No |
|---|
| signed firmware update | Yes |
|---|---|
| safely removing data | Yes |
| data integrity | Yes |
| Ambient temperature during operation: min. | 0 °C |
|---|---|
| Ambient temperature during operation: max. | 55 °C |
| Design of electrical connection for the inputs and outputs | M12, 5-pin, A-coded |
|---|
| Width | 45 mm |
|---|---|
| Height | 130 mm |
| Depth | 35 mm |
| Weight, approx. | 150 g |
|---|
| eClass | 7.1 27-24-26-08 |
|---|---|
| ETIM | 10 EC001604 |
| IDEA | 4 3564 |
| UNSPSC | 15 32-15-17-05 |
| China RoHS Manufacturer Declara- | tion |
|---|
| Net weight | 0.181 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.681 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of 6ES7147-4JD00-0AB0 is 24 V AC.
The tariff (HS) code on file for 6ES7147-4JD00-0AB0 is 85389091.
The EAN (GTIN) of 6ES7147-4JD00-0AB0 is 4047623406495.
6ES7147-4JD00-0AB0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.