The Siemens 6ES7143-6BH00-0BB0 is a SIMATIC ET 200eco PN module with 16 channels parameterizable as digital input or output, switching up to 2 A per channel at 24 V DC through 8x M12-L connectors. It runs PROFINET IO, EtherNet/IP and Modbus TCP over an integrated 2-port switch, rated IP67/IP69K for washdown mounting.
The dual current rating - 0.5 A or 2 A per channel, set per output during configuration - lets one module cover both signal-level loads and small actuators like solenoid valves or indicator beacons without splitting them across two I/O cards. Multi-fieldbus support (PROFINET IO, EtherNet/IP, Modbus TCP) on the same hardware means the module doesn't need reordering if a cell's controller platform changes. PROFINET S2 system redundancy and MRP support make it a fit for stations on a redundant or ring-topology network where a single switch or cable fault can't take the I/O offline.
Suits IP69K washdown environments and machine-mounted stations needing higher-current digital outputs than typical M12 I/O blocks provide, such as valve manifolds, conveyor drives or beacon circuits on food/beverage or automotive lines running PROFINET, EtherNet/IP or Modbus TCP.
| HW functional status | FS05 |
|---|---|
| Firmware version | V5.1.x |
| FW update possible | Yes |
| Vendor identification (VendorID) | 002 AH |
| Device identifier (DeviceID) | 0306 H |
| Manufacturer ID according to ODVA (VendorID) | 04E3H |
| Device ID according to ODVA (Product code) | 0FA8H |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: IRT | Yes |
| Product function: Prioritized startup | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | STEP 7 V17 or higher with HSP 0363 |
| Engineering with: PROFINET from GSD version/GSD revision | GSDML V2.4.x |
| Engineering with: Multi Fieldbus Configuration Tool (MFCT) | from V1.3 SP1 |
| Operating mode: DI | Yes |
| Operating mode: Counter | No |
| Operating mode: DQ | Yes |
| Operating mode: MSI | Yes |
| Operating mode: MSO | Yes |
| power supply according to NEC Class 2 required | No |
|---|---|
| Load voltage 1L+: Rated value (DC) | 24 V |
| Load voltage 1L+: permissible range, lower limit (DC) | 20.4 V |
| Load voltage 1L+: permissible range, upper limit (DC) | 28.8 V |
| Load voltage 1L+: Reverse polarity protection | Yes; Against destruction; encoder power supply outputs applied with reversed polarity, loads pick up |
| Load voltage 2L+: Rated value (DC) | 24 V |
| Load voltage 2L+: permissible range, lower limit (DC) | 20.4 V |
| Load voltage 2L+: permissible range, upper limit (DC) | 28.8 V |
| Load voltage 2L+: Reverse polarity protection | Yes; against destruction |
| Current consumption (rated value) | 90 mA; without load |
|---|---|
| from load voltage 1L+ (unswitched voltage) | 12 A; Maximum value |
| from load voltage 2L+, max. | 12 A; Maximum value |
| Part number | 6ES7143-6BH00-0BB0 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623410867 |
| ETIM class | EC001599 |
| eCl@ss | 27242604 |
| Number of outputs | 8 |
|---|---|
| 24 V encoder supply: Short-circuit protection | Yes; Group-by-group for 2 channels, electronic |
| 24 V encoder supply: Output current, max. | 100 mA; per output |
| Power loss, typ. | 9.7 W |
|---|
| Address space per module: Inputs | 2 byte; + 4 bytes for QI information |
|---|---|
| Address space per module: Outputs | 2 byte |
| Submodules: Number of configurable submodules, max. | 2 |
|---|
| Number of digital inputs | 16; Parameterizable as DIQ |
|---|---|
| in groups of | 8 |
| Digital inputs, parameterizable | Yes |
| Sourcing/sinking input | P-reading |
| Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
| Number of simultaneously controllable inputs all mounting positions: up to 60 °C, max. | 16 |
| Input voltage: Rated value (DC) | 24 V |
| Input voltage: for signal "0" | -3 to +5V |
| Input voltage: for signal "1" | +11 to +30V |
| Input current: for signal "1", typ. | 2.4 mA |
| Input delay (for rated value of input voltage) for standard inputs: parameterizable | Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms |
| Cable length: unshielded, max. | 30 m |
| Number of digital outputs | 16; Parameterizable as DIQ |
|---|---|
| in groups of | 8; 2 load groups for 8 outputs each |
| Current-sourcing | Yes |
| output type acc. to IEC 61131, type 0.5 | Yes |
| output type acc. to IEC 61131, type 2 | Yes |
| Short-circuit protection | Yes; per channel, electronic |
| Response threshold, typ. | 0.5 A: 1 A / 2 A: 3 A |
| Limitation of inductive shutdown voltage to | 0.5 A: Type 1L+ (-70 V) / 2 A: Type (-18 V) |
| Controlling a digital input | Yes |
| Switching capacity of the outputs: with resistive load, max. | 0.5 A / 2 A |
| Switching capacity of the outputs: with inductive load, max. | 0.5 A / 2 A |
| Switching capacity of the outputs: on lamp load, max. | 0.5 A: 5 W / 2 A 10 W |
| Load resistance range: lower limit | 0.5 A: 48 ohms / 2 A: 12 ohms |
| Load resistance range: upper limit | 4 kΩ |
| Output voltage: for signal "1", min. | 1L+ (-0.8 V) / 2L+ (-0.8 V) |
| Output current: for signal "1" rated value | 0.5 A / 2 A |
| Output current: for signal "1" permissible range, max. | 0.5 A / 2 A |
| Output current: for signal "0" residual current, max. | 0.1 mA |
| Output delay with resistive load: "0" to "1", max. | 0.5 A: 100 µs / 2 A: 150 µs; at rated load |
| Output delay with resistive load: "1" to "0", max. | 0.5 A: 150 µs / 2 A: 2.5 ms; at rated load |
| Parallel switching of two outputs: for uprating | No |
| Parallel switching of two outputs: for redundant control of a load | Yes |
| Switching frequency: with resistive load, max. | 0.5 A: 100 Hz / 2 A: 40 Hz |
| Switching frequency: with inductive load, max. | 0.5 Hz |
| Switching frequency: on lamp load, max. | 1 Hz |
| Total current of the outputs: Current per group, max. | 1L+: 2 A / 2L+: 6 A |
| Total current of the outputs: Current per module, max. | 8 A |
| Cable length: unshielded, max. | 30 m |
| Connectable encoders: 2-wire sensor | Yes |
|---|---|
| Connectable encoders: permissible quiescent current (2-wire sensor), max. | 1.5 mA |
| Transmission procedure | 100BASE-TX |
|---|---|
| Number of PROFINET interfaces | 1 |
| Interface type | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
|---|---|
| Interface types: M12 port | Yes; 2x M12, 4-pin, D-coded |
| Interface types: Number of ports | 2 |
| Interface types: integrated switch | Yes |
| Protocols: PROFINET IO Device | Yes |
| Protocols: Open IE communication | Yes |
| PROFINET IO Device Services: IRT | Yes; 250 µs to 4 ms in 125 µs frame |
| PROFINET IO Device Services: Prioritized startup | Yes |
| PROFINET IO Device Services: Shared device | Yes |
| PROFINET IO Device Services: Number of IO Controllers with shared device, max. | 2 |
| M12 port: Autonegotiation | Yes |
|---|---|
| M12 port: Autocrossing | Yes |
| M12 port: Transmission rate, max. | 100 Mbit/s |
| Supports protocol for PROFINET IO | Yes |
|---|---|
| PROFIsafe | No |
| EtherNet/IP | Yes |
| Modbus TCP | Yes |
| Redundancy mode: PROFINET system redundancy (S2) | Yes |
| Redundancy mode: on S7-1500R/H | Yes |
| Redundancy mode: on S7-400H | Yes |
| Redundancy mode: PROFINET system redundancy (R1) | No |
| Redundancy mode: H-Sync forwarding Media redundancy | Yes |
| Redundancy mode: MRP | Yes |
| Redundancy mode: MRPD | No |
| EtherNet/IP Services: CIP Implicit Messaging | Yes |
| EtherNet/IP Services: CIP Explicit Messaging | Yes |
| EtherNet/IP Services: CIP Safety | No |
| EtherNet/IP Services: Shared device | Yes; 2x EtherNet/IP Scanner |
| EtherNet/IP Services: Number of scanners with shared device, max. Updating times | 2 |
| EtherNet/IP Services: Requested Packet Interval (RPI) Redundancy mode | 2 ms |
| EtherNet/IP Services: DLR (Device Level Ring) Address area | No |
| EtherNet/IP Services: Address space per module, max. | 20 byte |
| EtherNet/IP Services: LargeForwardOpen (Class3) | No |
| Modbus TCP Services: read coils (code=1) | Yes |
| Modbus TCP Services: read discrete inputs (code=2) | Yes |
| Modbus TCP Services: Read Holding Registers (Code=3) | Yes |
| Modbus TCP Services: write single coil (code=5) | Yes |
| Modbus TCP Services: write multiple coils (code=15) | Yes |
| Modbus TCP Services: Write Multiple Registers (Code=16) | Yes |
| Modbus TCP Services: Parameter change by master | No |
| Modbus TCP Services: Modbus TCP Security Protocol Address space per station | No |
| Modbus TCP Services: Address space per station, max. | 20 byte |
| Modbus TCP Services: Access-consistent address space Updating time | 2 byte |
| Modbus TCP Services: I/O request interval Connections | 2 ms |
| Modbus TCP Services: number of connections per device | 12 |
| Open IE communication: TCP/IP | Yes; (only EtherNet/IP or Modbus TCP) |
| Open IE communication: SNMP | Yes |
| Open IE communication: LLDP | Yes |
| Open IE communication: ARP | Yes |
| Substitute values connectable | Yes |
|---|---|
| Alarms: Diagnostic alarm | Yes; Parameterizable |
| Alarms: Maintenance interrupt | Yes; Parameterizable |
| Alarms: Hardware interrupt | Yes; Parameterizable |
| Diagnoses: Diagnostic information readable | Yes |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: parameterizable | Yes |
| Diagnoses: Wire break | Yes; DI, input current < 0.3 mA, per channel |
| Diagnoses: Short-circuit | Yes; Outputs to M and P; channel by channel |
| Diagnoses: Short-circuit encoder supply | Yes; Per channel group |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED: NS LED | Yes; green/red LED |
| Diagnostics indication LED: MS LED | Yes; green/red LED |
| Diagnostics indication LED: IO LED | Yes; red/green/yellow LEDs |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: For load voltage monitoring | Yes; green LED |
| Diagnostics indication LED: Connection display LINK TX/RX | Yes; green LED, only link |
| between the load voltages | Yes |
|---|---|
| between Ethernet and electronics | Yes |
| Potential separation channels: between the channels | Yes |
| Potential separation channels: between the channels, in groups of | 8 |
| Potential separation channels: between the channels and the power supply of the | 8 channels are non-isolated and 8 channels are isolated from supply voltage |
| electronics | 1L+ |
| tested with: 24 V DC circuits | 707 V DC (type test) |
|---|---|
| tested with: Test voltage for interface, rms value [Vrms] | 1 500 V; According to IEEE 802.3 |
| IP degree of protection | IP65/67/69K |
|---|
| Suitable for safety-related tripping of standard modules | Yes; from FS01 |
|---|---|
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 63 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 12.7 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 52.8 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -2.65 kg |
| Highest safety class achievable for safety-related tripping of standard modules: Performance level according to ISO 13849-1 | PL d |
| Use in hazardous areas: Explosion protection category for gas | ATEX, UKEX, IECEx, CCCEx for Zone 2 |
| Use in hazardous areas: Explosion protection category for dust | ATEX, UKEX, IECEx, CCCEx for Zone 22 |
| signed firmware update | Yes |
|---|---|
| securely removing data | Yes |
| Ambient temperature during operation: min. | -40 °C |
|---|---|
| Ambient temperature during operation: max. | 60 °C |
| Altitude during operation relating to sea level: Ambient air temperature-barometric pressure-altitude | Up to max. 5 000 m, at installation height > 2 000 m additional restrictions |
| Design of electrical connection | 4/5-pin M12 circular connectors |
|---|---|
| Design of electrical connection for the inputs and outputs | M12, 5-pin, A-coded |
| Design of electrical connection for supply voltage | M12, 4-pin, L-coded |
| Width | 45 mm |
|---|---|
| Height | 200 mm |
| Depth | 48 mm |
| Weight, approx. | 780 g |
|---|
| Net weight | 0.818 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 1.318 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 6ES7143-6BH00-0BB0 is 0.5 A.
The rated operational voltage of 6ES7143-6BH00-0BB0 is 24 V AC.
The tariff (HS) code on file for 6ES7143-6BH00-0BB0 is 85389091.
The EAN (GTIN) of 6ES7143-6BH00-0BB0 is 4047623410867.
6ES7143-6BH00-0BB0 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.