The Siemens 6ES7142-5AF00-0BL0 is a SIMATIC ET 200AL IO-Link output module with 8 channels rated 2 A at 24 V DC, wired through 8x M12 connectors and communicating over IO-Link 1.1 at 38.4 kBd. Output current derates from 2 A at 45 degC to 1 A at 55 degC, and the module is suitable for safety-related tripping of standard modules to PL d / SIL 2 from firmware FS01.
Pick the IO-Link variant over the standard hard-wired DQ module when the IO-Link master needs to configure or monitor the output channel state remotely, at the cost of an 8 A total output budget instead of 2 A per channel available on every port simultaneously. The current rating derates from 2 A at 45 degC to 1 A at 55 degC, so a hot cabinet-free installation near the top of that range needs the load sized against 1 A, not the nameplate 2 A. PL d / SIL 2 safety-related tripping support from firmware FS01 still applies, same as the non-IO-Link version.
Field-mounted actuator control on IO-Link networks - solenoid valves, indicator lamps, and small loads up to 2 A per channel where the IO-Link master needs diagnostic or configuration access to the output module itself.
| Product type designation | IO-Link DQ 8x24VDC/2A |
|---|---|
| HW functional status | FS01 |
| Firmware version | V1.0.x |
| Vendor identification (VendorID) | 42 |
| Device identifier (DeviceID) | 229381 |
| Engineering with: IODD file | Yes |
| Load voltage 1L+: Rated value (DC) | 24 V; Supply from 1Us+ of the IO-Link master |
|---|---|
| Load voltage 1L+: permissible range, lower limit (DC) | 18 V |
| Load voltage 1L+: permissible range, upper limit (DC) | 30 V |
| Load voltage 1L+: Reverse polarity protection | Yes; against destruction |
| Load voltage 2L+: Rated value (DC) | 24 V; Supply via M12 connector L-coded |
| Load voltage 2L+: permissible range, lower limit (DC) | 20.4 V |
| Load voltage 2L+: permissible range, upper limit (DC) | 28.8 V |
| Load voltage 2L+: Reverse polarity protection | Yes; against destruction; load increasing |
| Current consumption (rated value) | 12 mA; without load |
|---|---|
| from load voltage 2L+, max. | 8 A; Maximum value |
| Part number | 6ES7142-5AF00-0BL0 |
|---|---|
| Type designation | IO-Link DQ 8x24VDC/2A |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623411390 |
| ETIM class | EC001599 |
| eCl@ss | 27242604 |
| Power loss, typ. | 3.6 W |
|---|
| Number of digital outputs | 8 |
|---|---|
| Current-sourcing | Yes |
| output type acc. to IEC 61131, type 2 | Yes |
| Short-circuit protection | Yes; per channel, electronic |
| Response threshold, typ. | 2.8 A |
| Limitation of inductive shutdown voltage to Switching capacity of the outputs | 2L+ (-47 V) |
| on lamp load, max. | 10 W |
| Load resistance range: lower limit | 12 Ω |
| Load resistance range: upper limit | 4 kΩ |
| Output voltage: for signal "1", min. | L+ (-0.8 V) |
| Output current: for signal "1" rated value | 2 A (45 °C); 1 A (55 °C) |
| Output current: for signal "1" permissible range, max. | 2 A; with inductive load to IEC 60947-5-1, DC-13 / AC-15 |
| Output current: for signal "0" residual current, max. | 0.5 mA |
| Switching frequency: with resistive load, max. | 100 Hz |
| Switching frequency: with inductive load, max. | 0.1 Hz; 0.25 Hz at 25 °C |
| Switching frequency: on lamp load, max. | 1 Hz |
| Total current of the outputs: Current per module, max. | 8 A |
| Cable length: unshielded, max. | 30 m |
| IO-Link protocol 1.1 | Yes |
|---|---|
| Transmission rate | 38.4 kBd (COM2) |
| Cycle time, min. | 2.1 ms |
| Size of process data, input per module | 0 byte |
| Size of process data, output per module | 1 byte |
| Supported IO-Link profiles | common profile |
| Cable length unshielded, max. | 20 m |
| Connection of IO-Link devices: Port type A | Yes |
| Substitute values connectable | Yes; channel by channel, parameterizable |
|---|---|
| Alarms: Diagnostic alarm | Yes; Parameterizable |
| Diagnoses: short-circuit | Yes; Outputs to ground; module by module |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for module diagnostics | Yes; green/red LED |
| Diagnostics indication LED: For load voltage monitoring | Yes; green LED |
| between the load voltages | Yes |
|---|---|
| Potential separation channels: between the channels | No |
| Potential separation channels: between the channels and the power supply of the electronics | Yes |
| Isolation tested with | 707 V DC (type test) |
|---|
| IP degree of protection | IP65/67 |
|---|
| Suitable for safety-related tripping of standard modules | Yes; from FS01 |
|---|---|
| Highest safety class achievable for safety-related tripping of standard modules: Performance level according to ISO 13849-1 | PL d |
| Ambient temperature during operation: min. | -30 °C |
|---|---|
| Ambient temperature during operation: max. | 55 °C |
| Design of electrical connection for the inputs and outputs | M12, 5-pin, A-coded |
|---|---|
| Type of electrical connection for IO-Link | M12, 5-pin, A-coded |
| Design of electrical connection for supply voltage | M12, 4-pin, L-coded |
| Width | 45 mm |
|---|---|
| Height | 159 mm |
| eClass | 16 27-24-26-04 |
|---|---|
| ETIM | 10 EC001599 |
| IDEA | 4 3566 |
| UNSPSC | 15 32-15-17-05 |
| China RoHS Manufacturer Declara- TUEV | tion |
|---|---|
| Maritime application NK / Nippon Kaiji Ky- | okai |
| Net weight | 0.193 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.693 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of IO-Link DQ 8x24VDC/2A is 2 A.
The tariff (HS) code on file for IO-Link DQ 8x24VDC/2A is 85389091.
The EAN (GTIN) of IO-Link DQ 8x24VDC/2A is 4047623411390.
IO-Link DQ 8x24VDC/2A ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.