The Siemens 6ES7138-7FA00-0AB0 is a fail-safe SIMATIC ET 200iSP analog input module with 4 HART-capable current channels for connecting 2-wire transmitters in intrinsically safe Zone 1 areas, certified SIL 3 per IEC 61508, PLe per ISO 13849-1, and Category 4 per EN 954-1. It runs on 19.2-30 V DC and supports HART protocol version 7.0.
HART pass-through lets this module read transmitter diagnostics and secondary variables over the 4-20 mA loop, so pick it over a plain fail-safe current input when HART device configuration or asset data is needed from the field. The SIL 3 / PLe / Category 4 rating means the fail-safe logic can sit directly in this I/O module rather than requiring a separate safety PLC downstream. Its Ex ib (ia Ga) IIC T4 Gb marking covers Zone 1 gas areas via the associated-apparatus concept, so 2-wire HART transmitters can be wired directly into the hazardous zone.
| Product type designation | 4F-AI I Ex HART |
|---|
| Rack mounting | No |
|---|---|
| Front mounting | Yes |
| Rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Type of supply voltage | DC |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 30 V |
| Part number | 6ES7138-7FA00-0AB0 |
|---|---|
| Type designation | 4F-AI I Ex HART |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 4019169224161 |
| Current consumption, typ. | 315 mA |
|---|---|
| from supply voltage L+, max. | 490 mA; int. Powerbus |
| Power supply to the transmitters: short-circuit proof | Yes |
|---|---|
| Power supply to the transmitters: Supply current, max. | 25 mA; Plus 4 mA per channel |
| Power loss, typ. | 3.8 W |
|---|---|
| Power loss, max. | 5.4 W |
| Address space per module: Address space per module, max. | 16 byte; 12 bytes in the I area / 4 bytes in the O area |
|---|
| Fieldbus connection via separate transceiver | Yes |
|---|
| Number of analog inputs | 4 |
|---|---|
| Cycle time (all channels) max. | See data in manual |
| Input ranges: Voltage | No |
| Input ranges: Current | Yes |
| Input ranges: Thermocouple | No |
| Input ranges: Resistance thermometer | No |
| Input ranges: Resistance | No |
| Input ranges (rated values), currents: 0 to 20 mA | Yes |
| Input ranges (rated values), currents: 4 mA to 20 mA | Yes |
| Cable length: shielded, max. | 500 m |
| Measurement principle | integrating (Sigma-Delta) |
|---|---|
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit |
| Integration and conversion time/resolution per channel: Integration time, parameterizable | Yes |
| Integration and conversion time/resolution per channel: Interference voltage suppression for interference frequency f1 in Hz | 50 / 60 Hz |
| Smoothing of measured values: Parameterizable | Yes; in 4 stages |
| Smoothing of measured values: Step: None | Yes; 1x cycle time |
| Smoothing of measured values: Step: low | Yes; 4x cycle time |
| Smoothing of measured values: Step: Medium | Yes; 16x cycle time |
| Smoothing of measured values: Step: High | Yes; 64x cycle time |
| Connection of signal encoders: for current measurement as 2-wire transducer | Yes |
|---|---|
| Connection of signal encoders: Burden of 2-wire transmitter, max. | 750 Ω |
| Linearity error (relative to input range), (+/-) | 0.015 % |
|---|---|
| Temperature error (relative to input range), (+/-) | 0.005 %/K |
| Crosstalk between the inputs, min. | -50 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.015 % |
| Operational error limit in overall temperature range: Current, relative to input range, (+/-) | 0.35 % |
| Basic error limit (operational limit at 25 °C): Current, relative to input range, (+/-) | 0.1 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency: Series mode interference (peak value of interference < rated value of input range), min. | 40 dB |
| Number of PROFINET interfaces | 0 |
|---|
| PROFINET IO | No |
|---|---|
| PROFIsafe | Yes |
| PROFIBUS | No |
| Further protocols: other bus systems | No |
| Alarms: Diagnostic alarm | Yes; Parameterizable |
|---|---|
| Diagnoses: Diagnostic information readable | Yes |
| Diagnoses: Wire break | Yes |
| Diagnoses: short-circuit | Yes |
| Diagnostics indication LED: Group error SF (red) | Yes |
| Potential separation analog inputs: between the channels | No |
|---|---|
| Potential separation analog inputs: between the channels and backplane bus | Yes |
| between different circuits | 60 V DC/30 V AC |
|---|
| IP degree of protection | IP30 |
|---|
| CE mark | Yes |
|---|---|
| Suitable for safety functions | Yes |
| reference designation according to IEC 81346-2 (2009) | K |
| Highest safety class achievable in safety mode: acc. to EN 954 | 4 |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | PLe |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 | SIL 3 |
| Use in hazardous areas: ATEX marking | II 2 G (1) GD Ex ib[ia Ga][ia IIIC Da] IIC T4 GB and I M2 Ex ib[ia Ma] I Mb |
| Use in hazardous areas: ATEX certificate | 10 ATEX 0058 |
| Use in hazardous areas: Explosion protection category for gas | ATEX gas explosion protection, Zone 1 |
| Use in hazardous areas: Explosion protection category for dust | ATEX dust explosion protection, Zone 21 always install in corresponding enclosure |
| Use in hazardous areas: associated equipment (Ex ia) | Yes |
| Use in hazardous areas: associated equipment (Ex ib) | Yes |
| Design of electrical connection | Screw/spring-type terminal |
|---|
| Width | 30 mm |
|---|---|
| Height | 129 mm |
| Depth | 136.5 mm |
| Weight, approx. | 299 g |
|---|
| Shipping weight | 0.799 kg |
|---|---|
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for 4F-AI I Ex HART is 85389091.
The EAN (GTIN) of 4F-AI I Ex HART is 4019169224161.
4F-AI I Ex HART ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.