How to Select an Interface Relay for PLC Outputs
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
The Siemens 6ES7138-7BB00-0AB0 is a watchdog module for the SIMATIC ET 200iSP intrinsically safe I/O station, monitoring the connected digital output modules on the power bus and reporting a group fault through its red SF LED. It runs from a 20.4-28.8 V DC supply, mounts on rail, front, or wall, and is rated IP30 with Ex ib IIC T4 Gb / Ex ib I Mb approval for Zone 1 gas and Group I mining areas.
This module has no digital inputs or fieldbus interfaces of its own; its job is watchdog supervision of the ET 200iSP power bus, so it is needed only when the station includes digital output modules whose power-bus feed must be monitored for a stuck or failed watchdog cycle. Its Ex ib IIC T4 Gb / Ex ib I Mb rating covers both surface gas Zone 1 installations and underground Group I mining areas from the same catalog number. The four marine class approvals (GL, ABS, BV, DNV) make it usable on shipboard hazardous-area I/O stations without a separate maritime-rated variant.
| Product type designation | Watchdog module |
|---|---|
| HW functional status | 4 |
| Firmware version | V1.0.2 |
| Rack mounting | No |
|---|---|
| Front mounting | Yes |
| Rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Type of supply voltage | DC |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Part number | 6ES7138-7BB00-0AB0 |
|---|---|
| Type designation | Watchdog module |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4019169149105 |
| ETIM class | EC001599 |
| eCl@ss | 27242604 |
| from load voltage (power bus), max. | 2 mA * number of connected digital output modules |
|---|
| Power loss, typ. | 50 mW |
|---|
| Fieldbus connection via separate transceiver | Yes |
|---|
| Number of digital inputs | 0 |
|---|
| Number of PROFINET interfaces | 0 |
|---|---|
| Number of RS 485 interfaces | 0 |
| Supports protocol for PROFINET IO | No |
|---|---|
| PROFIsafe | No |
| PROFIBUS | No |
| Diagnoses: Diagnostic information readable | Yes |
|---|---|
| Diagnostics indication LED: Group error SF (red) | Yes |
| Diagnostics indication LED: Status indicator digital input (green) | Yes |
| Module for Ex(i) protection | Yes; for more Co/Lo combinations, see certificate IECEx KEM 06.0026 |
|---|---|
| maximum values for connecting terminals for gas group IIC: Uo (no-load voltage), max. | 12.7 V |
| maximum values for connecting terminals for gas group IIC: Io (short-circuit current), max. | 329 mA |
| maximum values for connecting terminals for gas group IIC: Po (power output), max. | 0.91 W |
| maximum values for connecting terminals for gas group IIC: Co (permissible external capacity), max. | 1 µF |
| maximum values for connecting terminals for gas group IIC: Lo (permissible external inductivity), max. | 0.3 mH |
| between the channels and backplane bus | Yes |
|---|---|
| between channels and powerbus | Yes |
| between different circuits | 60 V DC/30 V AC |
|---|
| IP degree of protection | IP30 |
|---|
| CE mark | CE 0344 |
|---|---|
| UKCA mark | DEKRA 21UKEX0028 Importer UK: Siemens plc Manchester M20 2UR |
| cULus | LISTED E334384 |
| FM approval | CLASSIFIED 3025852 |
| Suitable for safety functions | No |
| INMETRO certificate | UL-BR 12.0075 |
| reference designation according to IEC 81346-2 (2009) | K |
| Use in hazardous areas: ATEX marking | II 2 G Ex ib IIC T4 Gb I M2 Ex ib I Mb |
| Use in hazardous areas: ATEX certificate | KEMA 06 ATEX 0086 |
| Use in hazardous areas: IECEx | IECEx KEM 06.0026 |
| Use in hazardous areas: CCC Ex | 2020322316002993 |
| Use in hazardous areas: EAC Ex | 1Ex ib IIC T4 Gb PB Ex ib I Mb |
| Use in hazardous areas: FM marking | Class I, Zone 1 AEx ib IIC T4 Ex ib IIC T4 NI, Class I, Division 2, GP. A,B,C,D T4 DIP, Class II, III, GP. E,F,G |
| Use in hazardous areas: Explosion protection category for gas | ATEX gas explosion protection, Zone 1 |
| Use in hazardous areas: Explosion protection category for dust | No |
| Use in hazardous areas: associated equipment (Ex ia) | No |
| Use in hazardous areas: associated equipment (Ex ib) | Yes |
| Marine approval: Germanischer Lloyd (GL) | Yes |
| Marine approval: American Bureau of Shipping (ABS) | Yes |
| Marine approval: Bureau Veritas (BV) | Yes |
| Marine approval: Det Norske Veritas (DNV) | Yes |
| Design of electrical connection | Screw/spring-type terminal |
|---|
| Width | 30 mm |
|---|---|
| Height | 129 mm |
| Depth | 136.5 mm |
| Net weight | 0.253 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.753 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for Watchdog module is 85389091.
The EAN (GTIN) of Watchdog module is 4019169149105.
Watchdog module ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.