Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7138-6CG00-0BA0 is a SIMATIC ET 200SP TM Timer DIDQ 10x24V module offering 4 time-stamped digital inputs and 6 digital outputs (0.5 A standard, or 0.1 A high-speed) with hardware time stamping, counting, and PWM output down to 1 microsecond switching delay. It mounts on BaseUnit type A0 with isochronous bus cycle from 375 microseconds.
The defining feature over a standard DI/DQ module is hardware time stamping on all 10 channels plus PWM output generation - useful when event timing accuracy matters more than PLC scan-cycle resolution, for example capturing exact trigger times for external inspection systems. High Speed output mode drops the current rating to 0.1 A per channel but cuts output delay to 1 microsecond versus 5-6 microseconds in Standard mode, a trade worth making only when switching speed, not load current, is the constraint. The 3 onboard counters (200 kHz max) make it usable as an encoder input module when a full TM Count module's 800 kHz range isn't needed.
Event-time capture, PWM-driven outputs, and moderate-speed encoder counting on ET 200SP remote I/O stations - for example synchronizing external triggers or capturing part-present timestamps on a packaging line.
| Product type designation | TM Timer DIDQ 10x24V |
|---|---|
| HW functional status | From FS03 |
| usable BaseUnits | BU type A0 |
| Product function: I&M data | Yes; I&M 0 |
| Product function: Isochronous mode | Yes |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V13 Update 3 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Rated value (DC) | 24 V |
|---|---|
| Load voltage L+: Rated value (DC) | 24 V |
| Load voltage L+: permissible range, lower limit (DC) | 19.2 V |
| Load voltage L+: permissible range, upper limit (DC) | 28.8 V |
| Load voltage L+: Reverse polarity protection | Yes; against destruction |
| Current consumption, max. | 50 mA; without load |
|---|
| Part number | 6ES7138-6CG00-0BA0 |
|---|---|
| Type designation | TM Timer DIDQ 10x24V |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623404712 |
| ETIM class | EC001601 |
| eCl@ss | 27242605 |
| Number of outputs | 1 |
|---|---|
| 24 V encoder supply: 24 V | Yes; L+ (-0.8 V) |
| 24 V encoder supply: Short-circuit protection | Yes |
| 24 V encoder supply: Output current, max. | 500 mA; Observe derating |
| Power loss, typ. | 1.5 W |
|---|
| Address space per module: Inputs | 26 byte |
|---|---|
| Address space per module: Outputs | 32 byte |
| Automatic encoding | Yes |
|---|---|
| Mechanical coding element | Yes |
| Type of mechanical coding element | type B |
| Number of digital inputs | 4 |
|---|---|
| Digital inputs, parameterizable | Yes |
| Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
| Digital input functions, parameterizable: Digital input with time stamp | Yes |
| Digital input functions, parameterizable: Number, max. | 4 |
| Digital input functions, parameterizable: Counter | Yes |
| Digital input functions, parameterizable: Counter for incremental encoder | Yes |
| Digital input functions, parameterizable: Digital input with oversampling | Yes |
| Digital input functions, parameterizable: HW enable for digital input | Yes |
| Input voltage: Type of input voltage | DC |
| Input voltage: Rated value (DC) | 24 V |
| Input voltage: for signal "0" | -5 ... +5 V |
| Input voltage: for signal "1" | +11 to +30V |
| Input voltage: permissible voltage at input, min. | -30 V; -5 V continuous, -30 V brief reverse polarity protection |
| Input voltage: permissible voltage at input, max. | 30 V |
| Input current: for signal "1", typ. | 2.5 mA |
| Input delay (for rated value of input voltage): Minimum pulse width for program reactions for standard inputs | 3 µs; for parameterization "none" |
| Input delay (for rated value of input voltage): parameterizable | Yes; none / 0.05 / 0.1 / 0.4 / 0.8 ms |
| Cable length: shielded, max. | 1 000 m; Depending on sensor, cable quality and rate of change |
| Cable length: unshielded, max. | 600 m; Depending on sensor, cable quality and rate of change |
| Type of digital output | Transistor |
|---|---|
| Number of digital outputs | 6 |
| Current-sinking | Yes; With High Speed output |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | Yes; electronic/thermal |
| Response threshold, typ. | 1.7 A with Standard output, 0.5 A with High Speed output |
| Limitation of inductive shutdown voltage to Digital output functions, parameterizable | -0.8 V |
| Digital output with time stamp | Yes |
| Number, max. | 6 |
| PWM output | Yes |
| Digital output with oversampling | Yes |
| Switching capacity of the outputs: with resistive load, max. | 0.5 A; 0.1 A with High Speed output |
| Switching capacity of the outputs: on lamp load, max. | 5 W; 1 W with High Speed output |
| Load resistance range: lower limit | 48 Ω; 240 ohm with High Speed output |
| Load resistance range: upper limit | 12 kΩ |
| Output voltage: Type of output voltage | DC |
| Output voltage: for signal "0", max. | 1 V; With High Speed output |
| Output voltage: for signal "1", min. | 23.2 V; L+ (-0.8 V) |
| Output current: for signal "1" rated value | 0.5 A; 0.1 A with High Speed output, observe derating |
| Output current: for signal "1" permissible range, max. | 0.6 A; 0.12 A with High Speed output, observe derating |
| Output current: for signal "1" minimum load current | 2 mA |
| Output current: for signal "0" residual current, max. | 0.5 mA |
| Output delay with resistive load: "0" to "1", max. | 1 µs; With High Speed output, 5 µs with Standard output |
| Output delay with resistive load: "1" to "0", max. | 1 µs; With High Speed output, 6 µs with Standard output |
| Switching frequency: with resistive load, max. | 10 kHz |
| Switching frequency: on lamp load, max. | 10 Hz |
| Total current of the outputs: Current per module, max. | 3.5 A; Observe derating |
| Cable length: shielded, max. | 1 000 m; depending on load and cable quality |
| Cable length: unshielded, max. | 600 m; depending on load and cable quality |
| Connectable encoders: Incremental encoder (asymmetrical) | Yes |
|---|---|
| Connectable encoders: 24 V initiator | Yes |
| Connectable encoders: 2-wire sensor | Yes |
| Connectable encoders: permissible quiescent current (2-wire sensor), max. | 1.5 mA |
| Encoder signals, incremental encoder (asymmetrical): Input voltage | 24 V |
| Encoder signals, incremental encoder (asymmetrical): Input frequency, max. | 50 kHz |
| Encoder signals, incremental encoder (asymmetrical): Counting frequency, max. | 200 kHz; with quadruple evaluation |
| Encoder signals, incremental encoder (asymmetrical): Cable length, shielded, max. | 600 m; Depending on input frequency, encoder and cable quality; max. 200 m at 50 kHz |
| Encoder signals, incremental encoder (asymmetrical): Incremental encoder with A/B tracks, 90° phase offset | Yes |
| Encoder signals, incremental encoder (asymmetrical): pulse encoder | Yes |
| Interface types: Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
| Number of RS 485 interfaces | 0 |
|---|
| Bus cycle time (TDP), min. | 375 µs |
|---|---|
| Jitter, max. | 1 µs |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Short-circuit | Yes |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: Channel status display | Yes |
| Diagnostics indication LED: for module diagnostics | Yes; green/red DIAG LED |
| Counter | Yes |
|---|---|
| Number of counters | 3 |
| Counting frequency, max. | 200 kHz; with quadruple evaluation |
| Counting functions: Continuous counting | Yes |
| Potential separation channels: between the channels and backplane bus | Yes |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Suitable for safety functions | No |
|---|
| eClass | 16 27-24-26-05 |
|---|---|
| ETIM | 10 EC001601 |
| IDEA | 4 3567 |
| UNSPSC | 15 32-15-17-05 |
| Miscellaneous Manufacturer Declara-tion | For use in hazard- |
|---|---|
| General Product Approval | ous locations |
| Net weight | 0.057 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.557 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of TM Timer DIDQ 10x24V is 0.5 A.
The rated operational voltage of TM Timer DIDQ 10x24V is 24 V DC.
The tariff (HS) code on file for TM Timer DIDQ 10x24V is 85389091.
The EAN (GTIN) of TM Timer DIDQ 10x24V is 4047623404712.
TM Timer DIDQ 10x24V ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.