Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7137-6AA01-0BA0 is a SIMATIC ET 200SP CM PtP point-to-point communication module with RS-422, RS-485, and RS-232 interfaces on push-in terminals, supporting Freeport, 3964(R), USS, and Modbus RTU master/slave protocols at up to 250 kbit/s. It mounts on BaseUnit type A0 and draws 31 mA typical from the ET 200SP backplane.
This module's value is protocol flexibility on one RS-422/485/232 port set - Freeport for custom ASCII devices, 3964(R) for legacy Siemens point-to-point links, and Modbus RTU master or slave for third-party instrumentation, all selectable in configuration rather than requiring separate hardware per protocol. RS-485's 1200 m cable range at reduced baud rate suits long-distance sensor or metering links across a plant floor; RS-232's 15 m limit restricts it to local device connections such as a barcode scanner at the panel. As a Modbus RTU master it addresses up to 32 slave devices, covering most single-segment instrumentation networks without a gateway.
Connecting ET 200SP stations to legacy serial devices, third-party instrumentation, or barcode and RFID readers over RS-232/422/485 where the plant network doesn't run PROFINET or PROFIBUS end-to-end.
| Product type designation | CM PtP |
|---|---|
| Firmware version: FW update possible | Yes |
| usable BaseUnits | BU type A0 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | STEP 7 V17 or higher |
| Engineering with: STEP 7 configurable/integrated from version | via GSD as of V5.6 HF4 |
| Engineering with: PROFIBUS from GSD version/GSD revision | GSD as of Revision 5 |
| Engineering with: PROFINET from GSD version/GSD revision | GSDML V2.34 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Current consumption (rated value) | 31 mA |
|---|---|
| Current consumption, max. | 35 mA |
| Part number | 6ES7137-6AA01-0BA0 |
|---|---|
| Type designation | CM PtP |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623411598 |
| ETIM class | EC001604 |
| eCl@ss | 27242608 |
| Power loss, typ. | 0.7 W |
|---|
| Address space per module: Address space per module, max. | 8 byte; performance mode: 32 byte |
|---|---|
| Address space per module: Inputs | 8 byte; performance mode: 32 byte |
| Address space per module: Outputs | 0 byte; performance mode: 32 byte |
| Automatic encoding | Yes |
|---|---|
| Mechanical coding element | Yes |
| Type of mechanical coding element | type D |
| Interface types: RS 485 | Yes |
|---|---|
| Interface types: RS 422 | Yes |
| Interface types: RS 232 | Yes |
| Interface types: Design of the connection | Push-in terminal |
| RS 232: Transmission rate, max. | 115.2 kbit/s |
|---|---|
| RS 232: Cable length, max. | 15 m |
| RS 232: RS 232 auxiliary signals | RTS, CTS, DTR, DSR, RI, DCD |
| RS 485: Transmission rate, max. | 250 kbit/s |
| RS 485: Cable length, max. | 1 200 m; 200 m to 1200 m, depending on transmission speed |
| RS 422: Transmission rate, max. | 115.2 kbit/s |
| RS 422: Cable length, max. | 1 200 m; 200 m to 1200 m, depending on transmission speed |
| RS 422: 4-wire full duplex connection | Yes |
| RS 422: 4-wire multipoint connection | Yes |
| Integrated protocols Freeport: Telegram length, max. | 2 kbyte; performance mode: receive data max. 24 byte and send data max. 30 byte |
|---|---|
| Integrated protocols Freeport: Bits per character | 7 or 8 |
| Integrated protocols Freeport: Number of stop bits | 1 or 2 bit |
| Integrated protocols Freeport: Parity 3964 (R) | None, even, odd, always 1, always 0, any |
| Integrated protocols Freeport: Parity Modbus RTU master | None, even, odd, always 1, always 0, any |
| Integrated protocols Freeport: Address area | 1 to 247, extended 1 to 65535 |
| Integrated protocols Freeport: max. number of devices Modbus RTU device | 32 |
| Telegram buffer: Buffer memory for telegrams | 4 kbyte |
| Telegram buffer: Number of telegrams which can be buffered | 255 |
| Diagnostics function | Yes |
|---|---|
| Alarms: Diagnostic alarm | Yes |
| Alarms: Hardware interrupt | No |
| Diagnoses: Wire break | Yes |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: for module diagnostics | Yes; green/red DIAG LED |
| Diagnostics indication LED: Receive RxD | Yes; green LED |
| Diagnostics indication LED: Transmit TxD | Yes; green LED |
| between backplane bus and interface | Yes |
|---|
| Isolation tested with | 707 V DC (type test) |
|---|
| Ecological footprint: environmental product declaration Global warming potential | Yes |
|---|---|
| Ecological footprint: global warming potential, (total) [CO2 eq] | 25.2 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 6.15 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 19.4 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.289 kg |
| Ambient temperature during operation: horizontal installation, min. | -30 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m |
| to SIMATIC S7-300 | Yes |
|---|---|
| to SIMATIC S7-400 | Yes |
| to SIMATIC S7-1200 | Yes |
| to SIMATIC S7-1500 | Yes |
| to standard PROFINET controller | Yes |
| Width | 15 mm |
|---|---|
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 30 g |
|---|
| Miscellaneous Manufacturer Declara- | tion |
|---|---|
| China RoHS Manufacturer Declara- | tion |
| Net weight | 0.039 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.539 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of CM PtP is 24 V DC.
The tariff (HS) code on file for CM PtP is 85176200.
The EAN (GTIN) of CM PtP is 4047623411598.
CM PtP ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.