The Siemens 6ES7136-6PA00-0BC0 is a SIMATIC ET 200SP F-PM-E fail-safe power module that switches 2 safe digital inputs and 1 safe PPM digital output rated 24 V DC / 8 A via PROFIsafe, reaching Performance Level PLe per ISO 13849-1 and SIL 3 per IEC 61508 for safe shutdown of downstream loads.
This F-PM-E variant switches a single 8 A PPM output on two safe inputs, so it fits applications needing one high-current safe shutdown point rather than a bank of channels; for higher safe-input or safe-output counts, the ET 200SP F-DI/F-DQ module family covers those channel-dense roles instead. Reaching PLe/SIL 3 requires the two-input safe circuit to be wired and configured as documented in the safety manual, and the 0.7-2.1 A electronic short-circuit threshold on the encoder supply lets it directly power PNP safety sensors without an external fuse.
Safe shutdown of a single high-current actuator, contactor coil, or valve bank in an ET 200SP distributed I/O station - for example an E-stop or guard-door circuit that must de-energize one 24 V DC / 8 A load up to PL e / SIL 3.
| Product type designation | F-PM-E 24 V DC/8 A PPM ST |
|---|---|
| usable BaseUnits | BU type C0 |
| Color code for module-specific color-coded label | CC52 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V12 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFINET from GSD version/GSD revision | V2.31 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Current consumption (rated value) | 75 mA; without load |
|---|---|
| Current consumption, max. | 21 mA; From the backplane bus |
| Part number | 6ES7136-6PA00-0BC0 |
|---|---|
| Type designation | F-PM-E 24 V DC/8 A PPM ST |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4025515082767 |
| ETIM class | EC002583 |
| eCl@ss | 27242611 |
| Rated value (DC) | 24 V |
|---|
| Number of outputs | 2 |
|---|---|
| Short-circuit protection | Yes; Electronic (response threshold 0.7 A to 2.1 A) |
| Output current: up to 60 °C, max. | 0.3 A |
| 24 V encoder supply: 24 V | Yes; min. L+ (-1.5 V) |
| 24 V encoder supply: Short-circuit protection | Yes |
| 24 V encoder supply: Output current, max. | 600 mA; Total current of all encoders |
| Power consumption from the backplane bus | 70 mW |
|---|
| Power loss, typ. | 5 W |
|---|
| Address space per module: Inputs | 7 byte |
|---|---|
| Address space per module: Outputs | 5 byte |
| Automatic encoding | Yes |
|---|---|
| Electronic coding element type F | Yes |
| Number of digital inputs | 2 |
|---|---|
| Sourcing/sinking input | Yes; P-reading |
| Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
| Input voltage: Type of input voltage | DC |
| Input voltage: Rated value (DC) | 24 V |
| Input voltage: for signal "0" | -30 to +5 V |
| Input voltage: for signal "1" | +15 to +30 V |
| Input current: for signal "1", typ. | 3.7 mA |
| Input delay (for rated value of input voltage) for standard inputs: parameterizable | Yes |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 500 m |
| Number of digital outputs | 1 |
|---|---|
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | Yes |
| Response threshold, typ. | > 14.8 A |
| Open-circuit detection | Yes |
| Overload protection | Yes |
| Limitation of inductive shutdown voltage to Switching capacity of the outputs | Max. -1.5 V |
| with resistive load, max. | 8 A |
| on lamp load, max. | 100 W |
| Load resistance range: lower limit | 3Ω |
| Load resistance range: upper limit | 2 000 Ω |
| Output voltage: for signal "1", min. | 24 V; L+ (-0.5 V) |
| Output current: for signal "1" rated value | 8 A |
| Output current: for signal "0" residual current, max. | 1.5 mA; PP-switching: max. 1.5 mA; PM-switching: max. 1 mA |
| Switching frequency: with resistive load, max. | 10 Hz; Symmetrical |
| Switching frequency: with inductive load, max. | 0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical |
| Switching frequency: on lamp load, max. | 4 Hz; Symmetrical |
| Total current of the outputs: Current per channel, max. | 8 A; note derating data in the manual |
| Total current of the outputs: Current per module, max. | 8 A; note derating data in the manual |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 500 m |
| Diagnostics function | Yes; See Chapter "Alarms/diagnostic messages" in the manual |
|---|---|
| Substitute values connectable | No |
| Alarms: Diagnostic alarm | Yes |
| Alarms: Hardware interrupt | No |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; green/red DIAG LED |
| Potential separation channels: between the channels | No |
|---|---|
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: between the channels and the power supply of the electronics | No |
| Isolation tested with | 707 V DC (type test) |
|---|
| Suitable for safety functions | Yes |
|---|---|
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 88.3 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 13.1 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 76.6 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -1.37 kg |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | PLe |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) | SIL 3 |
| Highest safety class achievable in safety mode: Low demand mode: PFDavg in accordance with SIL2 | < 2.00E-04 |
| Highest safety class achievable in safety mode: High demand/continuous mode: PFH in accordance with SIL2 | < 1.00E-08 1/h |
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 4 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP System Manual |
| Width | 20 mm |
|---|---|
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 70 g |
|---|
| ETIM | 8 EC002583 |
|---|---|
| IDEA | 4 3575 |
| UNSPSC | 15 32-15-17-06 |
| Net weight | 0.08 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.58 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of F-PM-E 24 V DC/8 A PPM ST is 8 A.
The rated operational voltage of F-PM-E 24 V DC/8 A PPM ST is 24 V AC.
The tariff (HS) code on file for F-PM-E 24 V DC/8 A PPM ST is 85389091.
The EAN (GTIN) of F-PM-E 24 V DC/8 A PPM ST is 4025515082767.
F-PM-E 24 V DC/8 A PPM ST ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.