Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Once production ends, supply depends on remaining stock.
No replacement announced yet. Tell us the application and we will propose an alternative.
The Siemens 6ES7136-6DB00-0CA0 is a SIMATIC ET 200SP fail-safe digital output module with 4 short-circuit-protected 24V DC transistor outputs rated 2A per channel, achieving Performance Level e / SIL 3 to ISO 13849-1 and IEC 61508, fitted to BU type A0.
Each of the 4 transistor outputs is individually short-circuit and overload protected, tripping at roughly 3.3A short-circuit / 2.9A overload, well above the 2A rated load, so a single shorted output doesn't force a module-wide shutdown. Open-circuit detection at 8mA lets the module flag a disconnected load even when the output is off, which matters for safety-related outputs where a broken wire needs to be caught before the next demand rather than discovered at the next real stop event. The 4W power loss is noticeably higher than the standard-range ET 200SP I/O modules, a consequence of the internal diagnostics and dual-channel safety switching path needed to reach PL e / SIL 3 - worth accounting for in enclosure thermal budgets when several of these sit side by side in a safety station.
Fail-safe 24V DC output for E-stop circuits, safety interlocks, and safety contactor/valve coil switching up to PL e / SIL 3 in SIMATIC ET 200SP-based safety stations, typically paired with a fail-safe relay output module for AC or higher-current loads.
| Product type designation | F-DQ 4x24VDC/2A PM HF |
|---|---|
| usable BaseUnits | BU type A0 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V12 |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFINET from GSD version/GSD revision | V2.31 |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| power supply according to NEC Class 2 required | No |
| Current consumption (rated value) | 75 mA; without load |
|---|---|
| Current consumption, max. | 21 mA; From the backplane bus |
| Part number | 6ES7136-6DB00-0CA0 |
|---|---|
| Type designation | F-DQ 4x24VDC/2A PM HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Phase-out announced by the manufacturer |
| EAN | 4025515082750 |
| ETIM class | EC001599 |
| eCl@ss | 27242604 |
| Rated value (DC) | 24 V |
|---|
| Power consumption from the backplane bus | 70 mW |
|---|
| Power loss, typ. | 4 W |
|---|
| Address space per module: Inputs | 5 byte |
|---|---|
| Address space per module: Outputs | 5 byte |
| Automatic encoding | Yes |
|---|---|
| Electronic coding element type F | Yes |
| Type of digital output | Transistor |
|---|---|
| Number of digital outputs | 4 |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | Yes |
| Response threshold, typ. | > 3.3 A |
| Open-circuit detection | Yes |
| Overload protection | Yes |
| Limitation of inductive shutdown voltage to | Typ. -2x 47 V |
| Controlling a digital input | Yes; digital output, according to IEC 61131-2, type 2 |
| Switching capacity of the outputs: with resistive load, max. | 2 A |
| Switching capacity of the outputs: on lamp load, max. | 10 W |
| Load resistance range: lower limit | 12 Ω |
| Load resistance range: upper limit | 2 000 Ω |
| Output voltage: for signal "1", min. | 24 V; L+ (-0.5 V) |
| Output current: for signal "1" rated value | 2 A |
| Output current: for signal "0" residual current, max. | 0.5 mA |
| Switching frequency: with resistive load, max. | 30 Hz; Symmetrical |
| Switching frequency: with inductive load, max. | 0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical |
| Switching frequency: on lamp load, max. | 10 Hz; Symmetrical |
| Total current of the outputs: Current per channel, max. | 2 A; note derating data in the manual |
| Total current of the outputs: Current per module, max. | 6 A; note derating data in the manual |
| Cable length: shielded, max. | 1 000 m |
| Cable length: unshielded, max. | 500 m |
| Diagnostics function | Yes; See Chapter "Alarms/diagnostic messages" in the manual |
|---|---|
| Substitute values connectable | No |
| Alarms: Diagnostic alarm | Yes |
| Alarms: Hardware interrupt | No |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; green/red DIAG LED |
| Potential separation channels: between the channels | No |
|---|---|
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: between the channels and the power supply of the electronics | No |
| Isolation tested with | 707 V DC (type test) |
|---|
| Suitable for safety functions | Yes |
|---|---|
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 88.3 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 13.1 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 76.6 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -1.37 kg |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | PLe |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) | SIL 3 |
| Highest safety class achievable in safety mode: Low demand mode: PFDavg in accordance with SIL2 | < 2.00E-04 |
| Highest safety class achievable in safety mode: High demand/continuous mode: PFH in accordance with SIL2 | < 1.00E-08 1/h |
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 4 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Width | 15 mm |
|---|---|
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 57 g |
|---|
| Net weight | 0.059 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.559 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of F-DQ 4x24VDC/2A PM HF is 2 A.
The rated operational voltage of F-DQ 4x24VDC/2A PM HF is 24 V DC.
The tariff (HS) code on file for F-DQ 4x24VDC/2A PM HF is 85389091.
The EAN (GTIN) of F-DQ 4x24VDC/2A PM HF is 4025515082750.
F-DQ 4x24VDC/2A PM HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.