Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7136-6CB00-0CA0 is a SIMATIC ET 200SP fail-safe technology module, F-TM Count 1x1Vpp sin/cos HF, that reads one incremental encoder with sin/cos 1 Vpp signals over PROFIsafe. It counts up to 800 kHz with quadruple evaluation and provides Safe Operating Stop, Safely-Limited Speed, Safe Direction and Safe Speed Monitor functions at PL e and SIL 3.
The single counter channel and PROFIsafe interface make the 6ES7136-6CB00-0CA0 fit for one safety-relevant axis position or speed feedback loop per module, rather than multi-axis monitoring. Its 800 kHz quadruple-evaluation counting frequency and SLS/SDI/SSM function set suit machine safety zones where a drive must be limited or stopped based on a safe-rated speed or direction signal from a sin/cos encoder, rather than a simple digital proximity switch.
| Product type designation | F-TM Count 1x1Vpp sin/cos HF |
|---|---|
| Firmware version | V1.0 |
| FW update possible | Yes |
| usable BaseUnits | BU type A0 |
| Color code for module-specific color-coded label | CC01 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | Step 7 V17 or higher: use GSDML for prior versions |
| Rated value (DC) | 24 V |
|---|---|
| power supply according to NEC Class 2 required | No |
| Load voltage L+: Rated value (DC) | 24 V |
| Load voltage L+: permissible range, lower limit (DC) | 20.4 V |
| Load voltage L+: permissible range, upper limit (DC) | 28.8 V |
| Load voltage L+: Reverse polarity protection | Yes |
| Current consumption, max. | 50 mA; without load, 150 mA with 300 mA encoder load |
|---|
| Part number | 6ES7136-6CB00-0CA0 |
|---|---|
| Type designation | F-TM Count 1x1Vpp sin/cos HF |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623411413 |
| ETIM class | EC001601 |
| eCl@ss | 27242605 |
| ●5V | Yes; 5.1 V ±3.5 % |
|---|---|
| Short-circuit protection | Yes; Electronic overload protection; no protection on applying a normal or counter voltage. |
| Output current, max. | 300 mA |
| Power loss, typ. | 1.25 W |
|---|
| Address space per module: Inputs | 14 byte; S7-300/400F CPU, 13 byte |
|---|---|
| Address space per module: Outputs | 5 byte; S7-300/400F CPU, 4 byte |
| Automatic encoding | Yes |
|---|---|
| Electronic coding element type H | Yes |
| Number of digital inputs | 1; (counter input) |
|---|---|
| Digital inputs, parameterizable | Yes |
| Digital input functions, parameterizable: Gate start/stop | Yes |
| Digital input functions, parameterizable: Counter for incremental encoder | Yes |
| Digital input functions, parameterizable: Number, max. | 1 |
| Input voltage: Type of input voltage | sin/cos 1 Vpp |
| Input delay (for rated value of input voltage): Minimum pulse width for program reactions for technological functions | 2.5 µs |
| Input delay (for rated value of input voltage): Parameterizable | Yes |
| Cable length: shielded, max. | 150 m |
| Connectable encoders: Incremental encoder (symmetrical) | Yes; up to 200 kHz depending on cable type and length |
|---|---|
| Encoder signals, incremental encoder (symmetrical): Input voltage | 1 Vpp, centered at 2.5 V offset |
| Encoder signals, incremental encoder (symmetrical): Input frequency, max. | 200 kHz |
| Encoder signals, incremental encoder (symmetrical): Counting frequency, max. | 800 kHz; with quadruple evaluation |
| Encoder signals, incremental encoder (symmetrical): Cable length, shielded, max. | 150 m |
| Encoder signals, incremental encoder (symmetrical): Incremental encoder with A/B tracks, 90° phase offset | Yes; sin/cos |
| Number of RS 485 interfaces | 0 |
|---|
| Diagnostics function | Yes; see chapter "Diagnostic Messages" in the manual |
|---|---|
| Alarms: Diagnostic alarm | Yes |
| Alarms: Hardware interrupt | No |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Wire break | Yes |
| Diagnoses: short-circuit | Yes |
| Diagnoses: A/B transition error at incremental encoder | Yes |
| Diagnostics indication LED: RUN LED | Yes; green LED |
| Diagnostics indication LED: ERROR LED | Yes; red LED |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | Yes; red LED |
| Diagnostics indication LED: for module diagnostics | Yes; green/red DIAG LED |
| Counter | Yes |
|---|---|
| Number of counters | 1 |
| Counting frequency, max. | 800 kHz; with quadruple evaluation |
| Safety monitoring functions: Safe Operating Stop (SOS) | Yes |
| Safety monitoring functions: Safely-Limited Speed (SLS) | Yes |
| Safety monitoring functions: Safe Direction (SDI) | Yes |
| Safety monitoring functions: Safe Speed Monitor (SSM) | Yes |
| Counting functions: Continuous counting | Yes |
| Counting functions: Counter response parameterizable | Yes |
| Counting functions: Software gate | Yes |
| Counting functions: Counting range, parameterizable | Yes |
| Measuring functions Measuring range: Frequency measurement, min. | 0.04 Hz |
| Measuring functions Measuring range: Frequency measurement, max. | 800 kHz; with quadruple evaluation |
| Measuring functions Measuring range: Cycle duration measurement, min. | 1 µs |
| Measuring functions Measuring range: Velocity measurement, min. | 0 (speed in configured units per selected time basis - speed*1 000) |
| Measuring functions Measuring range: Velocity measurement, max. Accuracy | 2 147 483 (speed in configured units per selected time basis - speed*1 000) |
| Measuring functions Measuring range: Frequency measurement | up to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3) |
| Measuring functions Measuring range: Velocity measurement | up to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3) |
| Potential separation channels: between the channels | No; Only one channel is available |
|---|---|
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: Between the channels and load voltage L+ | No |
| Potential separation channels: between the channels and the power supply of the electronics | No |
| Isolation tested with | 707 V DC (type test) |
|---|
| Suitable for safety functions | Yes |
|---|---|
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 88.3 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 13.1 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 76.6 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -1.37 kg |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | Cat. 4, PLe |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 Probability of failure (for service life of 20 years and repair time of 100 hours) | SIL 3 |
| Highest safety class achievable in safety mode: low demand mode: PFDavg in accordance with SIL1 | < 2.00E-03 signal monitoring disabled |
| Highest safety class achievable in safety mode: high demand/continuous mode: PFH in accordance with SIL1 | < 3.00E-08 1/h signal monitoring disabled |
| Ambient temperature during operation: horizontal installation, min. | 0 °C |
|---|---|
| Ambient temperature during operation: vertical installation, min. | 0 °C |
| Altitude during operation relating to sea level: Ambient air temperature-barometric pressure-altitude | On request: Installation altitudes greater than 2 000 m |
| Width | 15 mm |
|---|---|
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 42 g |
|---|
| eClass | 16 27-24-26-05 |
|---|---|
| ETIM | 10 EC001601 |
| IDEA | 4 3567 |
| UNSPSC | 15 32-15-17-05 |
| Manufacturer Declara- Miscellaneous tion | For use in hazard- |
|---|---|
| General Product Approval | ous locations |
| TUEV NK / Nippon Kaiji Ky- | okai |
|---|
| Net weight | 0.055 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.555 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of F-TM Count 1x1Vpp sin/cos HF is 24 V AC.
The tariff (HS) code on file for F-TM Count 1x1Vpp sin/cos HF is 85389091.
The EAN (GTIN) of F-TM Count 1x1Vpp sin/cos HF is 4047623411413.
F-TM Count 1x1Vpp sin/cos HF ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.