The Siemens 6ES7136-6CB00-0CA0 is a SIMATIC ET 200SP fail-safe technology module, F-TM Count 1x1Vpp sin/cos HF, that reads one incremental encoder with sin/cos 1 Vpp signals over PROFIsafe. It counts up to 800 kHz with quadruple evaluation and provides Safe Operating Stop, Safely-Limited Speed, Safe Direction and Safe Speed Monitor functions at PL e and SIL 3.
Technical Specifications
| SKU | 6ES7136-6CB00-0CA0 |
| Brand | Siemens |
| Series | SIMATIC ET 200SP |
| Product Type Designation | F-TM Count 1x1Vpp sin/cos HF |
| Usable BaseUnits | BU type A0 |
| Number of Digital Inputs | 1 counter input |
| Input Voltage Type | sin/cos 1 Vpp, centered at 2.5 V offset |
| Input Frequency, max. | 200 kHz |
| Counting Frequency, max. | 800 kHz, with quadruple evaluation |
| Safety Monitoring Functions | Safe Operating Stop (SOS), Safely-Limited Speed (SLS), Safe Direction (SDI), Safe Speed Monitor (SSM) |
| Performance Level (ISO 13849-1) | Cat. 4, PL e |
| SIL Rating (IEC 61508) | SIL 3 |
| PFDavg (SIL 3, 20-year service life) | less than 3.00E-05 |
| PFH (SIL 3, 20-year service life) | less than 1.00E-09 per hour |
| Load Voltage L+ (DC) | 24 V, 20.4-28.8 V range |
| 5 V Encoder Supply, max. | 300 mA, short-circuit protected |
| Power Loss, typ. | 1.25 W |
| Cable Length, shielded, max. | 150 m |
| Width x Height x Depth | 15 x 73 x 58 mm |
| Net Weight | 0.042 kg |
| Country of Origin | DE |
Selection Notes
The single counter channel and PROFIsafe interface make the 6ES7136-6CB00-0CA0 fit for one safety-relevant axis position or speed feedback loop per module, rather than multi-axis monitoring. Its 800 kHz quadruple-evaluation counting frequency and SLS/SDI/SSM function set suit machine safety zones where a drive must be limited or stopped based on a safe-rated speed or direction signal from a sin/cos encoder, rather than a simple digital proximity switch.