The Siemens 6ES7135-6FB00-0BA1 is a SIMATIC ET 200SP AQ 2xU Standard analog output module with 2 voltage outputs at up to 16-bit resolution on a ±10 V range. It runs on 24 V DC, draws 80 mA, and mounts on BaseUnit type A0 or A1. Output ranges include 0-10 V, 1-5 V, ±5 V and ±10 V, with diagnostics for short-circuit and supply-voltage faults.
The AQ 2xU Standard module gives 2 independent voltage channels at up to 16-bit resolution, useful where the ±10 V range needs full-scale accuracy for closed-loop control, such as driving a proportional valve or a VFD analog reference. Standard-grade channels are isolated from the backplane bus and electronics supply but not channel to channel — for applications needing channel-to-channel isolation, the High Feature variant in the same 15 mm housing is the alternative. It occupies a single BaseUnit slot (type A0 or A1), so 2 output channels take the same rack space as many single-channel ET 200SP modules.
Suited to ET 200SP stations distributing analog setpoints to VFDs, proportional valves, or positioners in a decentralized I/O architecture.
| Product type designation | AQ 2xU ST |
|---|---|
| HW functional status | from FS21 |
| Firmware version | V1.0.3 |
| FW update possible | Yes |
| usable BaseUnits | BU type A0, A1 |
| Color code for module-specific color-coded label | CC00 |
| Product function: I&M data | Yes; I&M0 to I&M3 |
| Product function: Isochronous mode | No |
| Product function: Output range scalable | No |
| Engineering with: STEP 7 TIA Portal configurable/integrated from version | V13 SP1 / - |
| Engineering with: STEP 7 configurable/integrated from version | V5.5 SP3 / - |
| Engineering with: PROFIBUS from GSD version/GSD revision | GSD Revision 5 |
| Engineering with: PROFINET from GSD version/GSD revision | GSDML V2.3 |
| Operating mode: Oversampling | No |
| Operating mode: MSO | No |
| Reparameterization possible in RUN | No |
|---|---|
| Calibration possible in RUN | No |
| Rated value (DC) | 24 V |
|---|---|
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Part number | 6ES7135-6FB00-0BA1 |
|---|---|
| Type designation | AQ 2xU ST |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4047623406709 |
| ETIM class | EC001596 |
| eCl@ss | 27242601 |
| Current consumption, max. | 80 mA |
|---|
| Power loss, typ. | 1 W |
|---|
| Address space per module: Address space per module, max. | 4 byte; + 1 byte for QI information |
|---|
| Automatic encoding | Yes |
|---|---|
| Mechanical coding element | Yes |
| Type of mechanical coding element | Type A |
| Number of analog outputs | 2 |
|---|---|
| Voltage output, short-circuit current, max. | 45 mA |
| Cycle time (all channels), min. | 1 ms |
| Analog output with oversampling | No |
| Output ranges, voltage: 0 to 10 V | Yes; 15 bit |
| Output ranges, voltage: 1 V to 5 V | Yes; 13 bit |
| Output ranges, voltage: -5 V to +5 V | Yes; 15 bit incl. sign |
| Output ranges, voltage: -10 V to +10 V | Yes; 16 bit incl. sign |
| Connection of actuators: for voltage output two-wire connection | Yes |
| Connection of actuators: for voltage output four-wire connection | No |
| Load impedance (in rated range of output): with voltage outputs, min. | 2 kΩ |
| Destruction limits against externally applied voltages and currents: Voltages at the outputs | 30 V |
| Cable length: shielded, max. | 200 m |
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit |
|---|---|
| Settling time: for resistive load | 0.1 ms |
| Settling time: for capacitive load | 1 ms |
| Linearity error (relative to output range), (+/-) | 0.03 % |
|---|---|
| Temperature error (relative to output range), (+/-) | 0.005 %/K |
| Crosstalk between the outputs, min. | -50 dB |
| Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.05 % |
| Operational error limit in overall temperature range: Voltage, relative to output range, (+/-) | 0.5 % |
| Operational error limit in overall temperature range: Current, relative to output range, (+/-) | 0.5 % |
| Basic error limit (operational limit at 25 °C): Voltage, relative to output range, (+/-) | 0.3 % |
| Basic error limit (operational limit at 25 °C): Current, relative to output range, (+/-) | 0.3 % |
| Diagnostics function | Yes |
|---|---|
| Substitute values connectable | Yes |
| Alarms: Diagnostic alarm | Yes |
| Diagnoses: Monitoring the supply voltage | Yes |
| Diagnoses: Short-circuit | Yes; module-wise |
| Diagnoses: Group error | Yes |
| Diagnoses: Overflow/Underflow | Yes; module-wise |
| Diagnostics indication LED: Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED: Channel status display | Yes; green LED |
| Diagnostics indication LED: for channel diagnostics | No |
| Diagnostics indication LED: for module diagnostics | Yes; green/red DIAG LED |
| Potential separation channels: between the channels | No |
|---|---|
| Potential separation channels: between the channels and backplane bus | Yes |
| Potential separation channels: between the channels and the power supply of the electronics | Yes |
| Isolation tested with | 707 V DC (type test) |
|---|
| Ecological footprint: environmental product declaration Global warming potential | Yes |
|---|---|
| Ecological footprint: global warming potential, (total) [CO2 eq] | 28.6 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 5.33 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 23.6 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.343 kg |
| Ambient temperature during operation: horizontal installation, min. | -30 °C; < 0 °C as of FS03 |
|---|---|
| Ambient temperature during operation: vertical installation, min. | -30 °C; < 0 °C as of FS03 |
| Altitude during operation relating to sea level: Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual |
| Absolute humidity: dew point, min. | -60 °C; suitable for dry room applications |
| Width | 15 mm |
|---|---|
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 31 g |
|---|
| Net weight | 0.039 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.539 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of AQ 2xU ST is 24 V AC.
The tariff (HS) code on file for AQ 2xU ST is 85389091.
The EAN (GTIN) of AQ 2xU ST is 4047623406709.
AQ 2xU ST ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.