Programmable Logic Controller Guide: Selection, Application, and Maintenance for Engineers
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
The Siemens 6ES7134-7SD00-0AB0 is an ET200iSP electronic module with 4 analog thermocouple inputs, certified Ex ib [ia Ga] IIC T4 Gb for installation in ATEX and IECEx Zone 1 hazardous areas. It accepts thermocouple types B, C, E, J, K, L, N, R, S, T and U plus a -80 mV to +80 mV voltage range, with 16-bit resolution and internal cold-junction compensation.
The internal cold-junction compensation via the supplied TC sensor module means this 4AI TC card needs no external compensation socket, unlike modules that rely on a separate analog channel for reference temperature. Its Ex ib [ia Ga] IIC T4 Gb rating restricts it to Zone 1 gas and Zone 21 dust areas rather than Zone 0; pick the HART 2-wire variant instead when the field instrument is a 4-20 mA transmitter rather than a bare thermocouple.
| Product type designation | 4AI TC |
|---|---|
| HW functional status | 7 |
| Firmware version | V1.0.1 |
| Reparameterization possible in RUN | Yes |
|---|
| Rack mounting | No |
|---|---|
| Front mounting | Yes |
| Rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Part number | 6ES7134-7SD00-0AB0 |
|---|---|
| Type designation | 4AI TC |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4019169132077 |
| ETIM class | EC001596 |
| eCl@ss | 27242601 |
| Type of supply voltage | DC |
|---|---|
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Current consumption, typ. | 17 mA |
|---|---|
| from load voltage (power bus), max. | 30 mA |
| Power loss, typ. | 0.4 W |
|---|
| Fieldbus connection via separate transceiver | Yes |
|---|
| Number of analog inputs | 4 |
|---|---|
| Cycle time (all channels) max. | 320 ms; 66 ms basic conversion time x 4 channels with interference frequency suppression 60 Hz, 80 ms basic conversion time x 4 channels with interference frequency suppression 50 Hz |
| Technical unit for temperature measurement adjustable | Yes |
| Input ranges: Voltage | Yes |
| Input ranges: Current | No |
| Input ranges: Thermocouple | Yes |
| Input ranges: Resistance thermometer | No |
| Input ranges: Resistance | No |
| Input ranges (rated values), voltages: -80 mV to +80 mV | Yes |
| Input ranges (rated values), voltages: Input resistance (-80 mV to +80 mV) | 1 000 kΩ |
| Input ranges (rated values), thermocouples: Type B | Yes |
| Input ranges (rated values), thermocouples: Input resistance (Type B) | 1 000 kΩ |
| Input ranges (rated values), thermocouples: Type C | Yes |
| Input ranges (rated values), thermocouples: Type E | Yes |
| Input ranges (rated values), thermocouples: Type J | Yes |
| Input ranges (rated values), thermocouples: Type K | Yes |
| Input ranges (rated values), thermocouples: Type L | Yes |
| Input ranges (rated values), thermocouples: Type N | Yes |
| Input ranges (rated values), thermocouples: Type R | Yes |
| Input ranges (rated values), thermocouples: Type S | Yes |
| Input ranges (rated values), thermocouples: Type T | Yes |
| Input ranges (rated values), thermocouples: Type U | Yes |
| Thermocouple (TC) Temperature compensation: internal temperature compensation | Yes; via supplied TC sensor module |
| Thermocouple (TC) Temperature compensation: external temperature compensation with | Yes; via temperature value, acquired by an analog module of the same ET |
| compensations socket | 200iSP station |
| Characteristic linearization: Parameterizable | Yes |
| Characteristic linearization: for thermocouples | Yes |
| Cable length: shielded, max. | 50 m |
| Measurement principle | integrating (Sigma-Delta) |
|---|---|
| Integration and conversion time/resolution per channel: Resolution with overrange (bit including sign), max. | 16 bit |
| Integration and conversion time/resolution per channel: Integration time, parameterizable | Yes |
| Integration and conversion time/resolution per channel: Basic conversion time, including integration time (ms) | 80 ms at 50 Hz; 66 ms at 60 Hz |
| Integration and conversion time/resolution per channel: additional conversion time for wire-break monitoring | 5 ms |
| Integration and conversion time/resolution per channel: Interference voltage suppression for interference frequency f1 in Hz | 50 / 60 Hz |
| Smoothing of measured values: parameterizable | Yes; in 4 stages |
| Smoothing of measured values: Step: None | Yes; 1x cycle time |
| Smoothing of measured values: Step: low | Yes; 4x cycle time |
| Smoothing of measured values: Step: Medium | Yes; 32x cycle time |
| Smoothing of measured values: Step: High | Yes; 64x cycle time |
| Linearity error (relative to input range), (+/-) | 0.015 % |
|---|---|
| Temperature error (relative to input range), (+/-) | 0.02 %/K |
| Crosstalk between the inputs, min. | -50 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.01 % |
| Operational error limit in overall temperature range: Voltage, relative to input range, (+/-) | 0.15 % |
| Basic error limit (operational limit at 25 °C): Voltage, relative to input range, (+/-) | 0.1 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency: Series mode interference (peak value of interference < rated value of input range), min. | 70 dB |
| Number of PROFINET interfaces | 0 |
|---|
| PROFINET IO | No |
|---|---|
| PROFIsafe | No |
| PROFIBUS | No |
| Further protocols: other bus systems | No |
| Alarms: Diagnostic alarm | Yes; Parameterizable |
|---|---|
| Alarms: Limit value alarm | Yes; Parameterizable |
| Diagnoses: Diagnostic information readable | Yes |
| Diagnoses: Wire break | Yes; R > 1.7 kOhm |
| Diagnostics indication LED: Group error SF (red) | Yes |
| Module for Ex(i) protection | Yes; for more Co/Lo combinations, see certificate IECEx KEM 05.0008 |
|---|---|
| maximum values for connecting terminals for gas group IIC: Uo (no-load voltage), max. | 5.9 V |
| maximum values for connecting terminals for gas group IIC: Io (short-circuit current), max. | 15 mA |
| maximum values for connecting terminals for gas group IIC: Po (power output), max. | 23 mW |
| maximum values for connecting terminals for gas group IIC: Co (permissible external capacity), max. | 43 µF |
| maximum values for connecting terminals for gas group IIC: Lo (permissible external inductivity), max. | 100 mH |
| between channels and powerbus | Yes |
|---|---|
| Potential separation analog inputs: between the channels | Yes; Functional |
| Potential separation analog inputs: between the channels and backplane bus | Yes |
| IP degree of protection | IP30 |
|---|
| CE mark | CE 0344 |
|---|---|
| UKCA mark | DEKRA 21UKEX0086 Importer UK: Siemens plc Manchester M20 2UR |
| cULus | LISTED E334384 |
| FM approval | CLASSIFIED 3025852 |
| Suitable for safety functions | No |
| INMETRO certificate | UL-BR 12.0071 |
| reference designation according to IEC 81346-2 (2009) | K |
| Highest safety class achievable in safety mode: acc. to EN 954 | n.a. |
| Highest safety class achievable in safety mode: Performance level according to ISO 13849-1 | none |
| Highest safety class achievable in safety mode: SIL acc. to IEC 61508 | No |
| Use in hazardous areas: ATEX marking | II 2 G (1) G Ex ib [ia Ga] IIC T4 Gb II 2 G (1) D Ex ib [ia IIIC Da] IIC T4 Gb I M2 Ex ib [ia] I Mb |
| Use in hazardous areas: ATEX certificate | KEMA 04 ATEX 1246 |
| Use in hazardous areas: IECEx | IECEx KEM 05.0008 |
| Use in hazardous areas: CCC Ex | 2020322316002943 |
| Use in hazardous areas: EAC Ex | PB Ex ib [ia] I Mb 1Ex ib [ia Ga] IIC T4 Gb [Ex ia Da] IIIC |
| Use in hazardous areas: FM marking | Class I, Zone 1 AEx ib [ia] IIC T4 Ex ib IIC T4 NI, Class I, DIV.2, GP. A,B,C,D T4 AIS, Class I, DIV.1, GP. A,B,C,D T4 DIP Class II, III, GP. E,F,G |
| Use in hazardous areas: Explosion protection category for gas | ATEX gas explosion protection, Zone 1 |
| Use in hazardous areas: Explosion protection category for dust | ATEX dust explosion protection, Zone 21 always install in corresponding enclosure |
| Use in hazardous areas: associated equipment (Ex ia) | Yes |
| Use in hazardous areas: associated equipment (Ex ib) | Yes |
| eClass | 16 27-24-26-01 |
|---|---|
| ETIM | 10 EC001596 |
| IDEA | 4 3562 |
| UNSPSC | 15 32-15-17-05 |
| Net weight | 0.32 kg |
|---|---|
| Country of origin | DE |
| Shipping weight | 0.82 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for 4AI TC is 85389091.
The EAN (GTIN) of 4AI TC is 4019169132077.
4AI TC ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.
Learn how a PLC works, including scan cycle, I/O sizing, IEC 61131-3 programming, and hardware selection for ABB, Schneider, and Siemens. Shop at Stoklink.
Master PLC system components: CPU, power supply, I/O modules, communication interfaces, and software with sizing formulas and selection tips. Shop at Stoklink.