The Siemens LOGO! DM8 230R (6ED1055-1FB00-0BA2) is a 2-module-wide digital expansion unit for the LOGO! 8 logic module family, adding 4 digital inputs and 4 relay outputs on a 115/230 V AC/DC supply. Each relay output switches up to 5 A resistive or 3 A inductive load, and the module mounts directly on the same DIN rail run as the base unit.
The DM8 230R's relay outputs, rated 5 A resistive and 3 A inductive, switch small motors, solenoids, and contactor coils directly, unlike transistor-output expansion modules that need an external relay for anything beyond a few hundred milliamps. Its 2-module width keeps the DIN rail footprint small when only 4 extra I/O points are needed.
Used to extend LOGO! 8 base units in machine control, lighting, and building automation panels where a handful of additional relay-switched outputs are needed without stepping up to a full PLC I/O rack.
| Mounting | on 35 mm DIN rail, 2 spacing units wide |
|---|
| Rated value (DC): 115 V DC | Yes |
|---|---|
| Rated value (DC): 230 V DC | Yes |
| permissible range, lower limit (DC) | 100 V |
| permissible range, upper limit (DC) | 253 V |
| Rated value (AC): 115 V AC | Yes |
| Rated value (AC): 230 V AC | Yes |
| Line frequency: permissible range, lower limit | 47 Hz |
| Line frequency: permissible range, upper limit | 63 Hz |
| Number of digital inputs | 4 |
|---|---|
| Input voltage: Type of input voltage | AC/DC |
| Input voltage: for signal "0" | < 40 V AC, < 30 V DC |
| Input voltage: for signal "1" | > 79 V AC, > 79 V DC |
| Input current: for signal "0", max. (permissible quiescent current) | 0.06 mA; 0.05 mA with AC, 0.06 mA with DC |
| Input current: for signal "1", typ. | 0.13 mA |
| Input delay (for rated value of input voltage) for standard inputs: at "0" to "1", max. | 40 ms |
| Part number | 6ED1055-1FB00-0BA2 |
|---|---|
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4034106029494 |
| ETIM class | EC001419 |
| eCl@ss | 27242204 |
| Number of digital outputs | 4; Relays |
|---|---|
| Short-circuit protection | No |
| Controlling a digital input | Yes |
| Switching capacity of the outputs: on lamp load, max. | 1 000 W; 500 W at 115V AC |
| Output current: for signal "1" rated value | 5 A |
| Output current: for signal "1" minimum load current | 100 mA |
| Parallel switching of two outputs: for uprating | No |
| Switching frequency: with resistive load, max. | 2 Hz |
| Switching frequency: with inductive load, max. | 0.5 Hz |
| Switching frequency: mechanical, max. | 10 Hz |
| Relay outputs Switching capacity of contacts: with inductive load, max. | 3 A |
| Relay outputs Switching capacity of contacts: with resistive load, max. | 5 A |
| Emission of radio interference acc. to EN 55 011: Limit class B, for use in residential areas | Yes |
|---|
| IP degree of protection | IP20 |
|---|
| CE mark | Yes |
|---|---|
| CSA approval | Yes |
| UL approval | Yes |
| FM approval | Yes |
| developed in accordance with IEC 61131 | Yes |
| according to VDE 0631 | Yes |
| Marine approval | Yes |
| Ecological footprint: environmental product declaration Global warming potential | Yes |
| Ecological footprint: global warming potential, (total) [CO2 eq] | 145 kg |
| Ecological footprint: global warming potential, (during production) [CO2 eq] | 7.49 kg |
| Ecological footprint: global warming potential, (during operation) [CO2 eq] | 138 kg |
| Ecological footprint: global warming potential, (after end of life cycle) [CO2 eq] | -0.491 kg |
| Ambient temperature during operation: min. | -20 °C; No condensation |
|---|---|
| Ambient temperature during operation: max. | 55 °C |
| Width | 35.5 mm |
|---|---|
| Height | 90 mm |
| Depth | 58 mm |
| Net weight | 0.167 kg |
|---|---|
| Country of origin | CN |
| Shipping weight | 0.667 kg |
| Ships from | Türkiye |
| Dispatch | 13 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 01 Nov 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 6ED1055-1FB00-0BA2 is 5 A.
The rated operational voltage of 6ED1055-1FB00-0BA2 is 115–230 V AC.
The tariff (HS) code on file for 6ED1055-1FB00-0BA2 is 85389091.
The EAN (GTIN) of 6ED1055-1FB00-0BA2 is 4034106029494.
6ED1055-1FB00-0BA2 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
A step-by-step guide to matching PLC output type, coil voltage and current, contact rating, and socket style when selecting an interface relay.
Compare the 5 main PLC types, IEC 61131-3 languages, scan-time sizing, and brand options to choose the right controller for your plant. Shop at...
PLC selection guide for engineers covering IEC 61131 compliance, Siemens, Rockwell, Schneider, ABB comparison, scan time sizing, and wiring. Shop at Stoklink.